All categories
Compare Cart

LP1K090085MD - TeSys K contactor 4P (2 NO + 2 NC) AC1 <= 440 V 20 A 220 V DC coil - Schneider Electric

Expected in 2-4 weeks
LP1K090085MD - TeSys K contactor 4P (2 NO + 2 NC) AC1 <= 440 V 20 A 220 V DC coil - Schneider Electric - TeSys K contactor 4P (2 NO + 2 NC) AC1 <= 440 V 20 A 220 V DC coil - Schneider Electric - 0
LP1K090085MD - TeSys K contactor 4P (2 NO + 2 NC) AC1 <= 440 V 20 A 220 V DC coil - Schneider Electric
38,31 € excl. VAT
46,74 € incl. VAT
Text About:
TeSys K contactor 4P (2 NO + 2 NC) AC1 <= 440 V 20 A 220 V DC coil - Schneider Electric
46,74 €
SPECIFICATIONS
Main
Contactor application Resistive load
Device short name LP1K
Range TeSys
[ui] rated insulation voltage Power circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V conforming to CSA C22.2 No 14
average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
Complementary
[ie] rated operational current 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit
16 A (at <70 °C) at 690 V AC AC-1 for power circuit
[ue] rated operational voltage Power circuit: 690 V AC 50/60 Hz
[ics] rated service breaking capacity 110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
110 A at 220...230 V conforming to IEC 60947
110 A at 380...400 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
[ith] conventional thermal current 20 A (at 50 °C) for power circuit
Product certifications CB Scheme
CCC
UL
CSA
EAC
CE
UKCA
Handle front plate colour 58 mm
Product or component type Contactor
[uimp] rated impulse withstand voltage 8 kV
Associated fuse rating 25 A gG at <= 440 V for power circuit
25 A aM for power circuit
Control circuit voltage limits Operational: 0.8...1.15 Uc (at <50 °C)
Drop-out: 0.1...0.75 Uc (at <50 °C)
width (w) 45 mm
Flame retardance V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Net weight 0.225 kg
Hold-in power consumption in w 3 W at 20 °C
Mounting support Printed circuit boards
depth 57 mm
inrush power in w 3 W (at 20 °C)
mechanical durability 10 Mcycles
Irms rated making capacity 110 A AC for power circuit conforming to NF C 63-110
110 A AC for power circuit conforming to IEC 60947
Maximum operating rate 3600 cyc/h
operating time 30...40 ms coil energisation and NO closing
10 ms coil de-energisation and NO opening
25...35 ms coil energisation and NC opening
15 ms coil de-energisation and NC closing
Pole contact composition 2 NO + 2 NC
Poles description 4P
Utilisation category AC-1
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Environment
Ambient air temp for storage/transportation -50…80 °C
operating altitude 2000 m without derating
Range of product TeSys K
ambient air temperature for operation -25…50 °C
overvoltage category III
standards EN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
Recently viewed
38,31 € excl. VAT
46,74 € incl. VAT
Expected in 2-4 weeks