All categories
Compare Cart

LP1D40008BD - TeSys Deca contactor 4P(2 NO + 2 NC) AC1 <= 440 V 60 A 24 V DC coil - Schneider Electric

Expected in 2-4 weeks
LP1D40008BD - TeSys Deca contactor 4P(2 NO + 2 NC) AC1 <= 440 V 60 A 24 V DC coil - Schneider Electric - TeSys Deca contactor 4P(2 NO + 2 NC) AC1 <= 440 V 60 A 24 V DC coil - Schneider Electric - 0
LP1D40008BD - TeSys Deca contactor 4P(2 NO + 2 NC) AC1 <= 440 V 60 A 24 V DC coil - Schneider Electric
194,54 €
194,54 € incl. VAT
Text About:
TeSys Deca contactor 4P(2 NO + 2 NC) AC1 <= 440 V 60 A 24 V DC coil - Schneider Electric
194,54 €
SPECIFICATIONS
Main
Contactor application Resistive load
Device short name LP1D
Range TeSys
[uc] control circuit voltage 24 V DC
[ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
control circuit type DC DC standard
average impedance 1.5 mOhm - Ith 60 A 50 Hz for power circuit
Complementary
[ie] rated operational current 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[ue] rated operational voltage Power circuit: <= 1000 V AC 25...400 Hz
compatibility code LP1D
[ics] rated service breaking capacity 800 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current 72 A 40 °C - 10 min for power circuit
165 A 40 °C - 1 min for power circuit
320 A 40 °C - 10 s for power circuit
720 A 40 °C - 1 s for power circuit
[ith] conventional thermal current 60 A (at 60 °C) for power circuit
Product certifications UL
CSA
CCC
EAC
UKCA
CB
DNV-GL
RINA
BV
LROS (Lloyds register of shipping)
Handle front plate colour 127 mm
Product or component type Contactor
tightening torque Power circuit: 8 N.m - on screw clamp terminals - cable 25…35 mm² hexagonal screw head 4 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 5 N.m - on screw clamp terminals - cable 1…25 mm² hexagonal screw head 4 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Connections - terminals Power circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 2.5…16 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: solid
Power circuit: screw clamp terminals 2 2.5…16 mm² - cable stiffness: solid
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid
Associated fuse rating 80 A gG at <= 690 V coordination type 1 for power circuit
80 A gG at <= 690 V coordination type 2 for power circuit
contact compatibility M3
Control circuit voltage limits 0.1...0.3 Uc (-40…70 °C):drop-out DC
0.85...1.1 Uc (-40…55 °C):operational DC
1...1.1 Uc (55…70 °C):operational DC
width (w) 85 mm
mechanical robustness Shocks contactor open (8 Gn for 11 ms)
Shocks contactor closed (10 Gn for 11 ms)
Vibrations contactor opened (2 Gn, 5...300 Hz)
Vibrations contactor closed (4 Gn, 5...300 Hz)
Flame retardance V1 conforming to UL 94
Net weight 2.21 kg
time constant 75 ms
Hold-in power consumption in w 22 W at 20 °C
Mounting support Plate
Rail
power dissipation per pole 5.4 W AC-1
depth 182 mm
inrush power in w 22 W (at 20 °C)
mechanical durability 10 Mcycles
electrical durability 1.4 Mcycles 60 A AC-1 at Ue <= 440 V
Irms rated making capacity 800 A at 440 V for power circuit conforming to IEC 60947
Pollution degree 3
Maximum operating rate 3600 cyc/h 60 °C
operating time 4...19 ms opening
12...26 ms closing
Protective cover Without
coil technology Built-in bidirectional peak limiting diode suppressor
Pole contact composition 2 NO + 2 NC
Poles description 4P
Utilisation category AC-1
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Environment
ip degree of protection IP20 front face conforming to IEC 60529
operating altitude 0...3000 m
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Range of product TeSys Deca
overvoltage category III
standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
fire resistance 850 °C conforming to IEC 60695-2-1
Recently viewed
194,54 €
194,54 € incl. VAT
Expected in 2-4 weeks