All categories
Compare Cart

LC7K0601M7 - TeSys K contactor 3P AC3 <= 440 V 6 A 1 NC aux. 220...230 V AC coil - Schneider Electric

Pending restock
LC7K0601M7 - TeSys K contactor 3P AC3 <= 440 V 6 A 1 NC aux. 220...230 V AC coil - Schneider Electric - TeSys K contactor 3P AC3 <= 440 V 6 A 1 NC aux. 220...230 V AC coil - Schneider Electric - 0
LC7K0601M7 - TeSys K contactor 3P AC3 <= 440 V 6 A 1 NC aux. 220...230 V AC coil - Schneider Electric
59,62 € excl. VAT
73,92 € incl. VAT
Text About:
TeSys K contactor 3P AC3 <= 440 V 6 A 1 NC aux. 220...230 V AC coil - Schneider Electric
73,92 €
SPECIFICATIONS
Main
Contactor application Motor control
Device short name LC7K
Range TeSys
[uc] control circuit voltage 220...230 V AC 50/60 Hz
Product Name TeSys K
[ui] rated insulation voltage Power circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Signalling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signalling circuit: 600 V conforming to CSA C22.2 No 14
control circuit type AC at 50/60 Hz silent
motor power kW 1.5 kW at 220...230 V AC 50/60 Hz AC-3
2.2 kW at 380...415 V AC 50/60 Hz AC-3
3 kW at 440 V AC 50/60 Hz AC-3
3 kW at 480 V AC 50/60 Hz AC-3
3 kW at 500...600 V AC 50/60 Hz AC-3
3 kW at 660...690 V AC 50/60 Hz AC-3
1.5 kW at 400 V AC 50/60 Hz AC-4
1.5 kW at 220...230 V AC 50/60 Hz AC-3e
2.2 kW at 380...415 V AC 50/60 Hz AC-3e
3 kW at 440 V AC 50/60 Hz AC-3e
3 kW at 480 V AC 50/60 Hz AC-3e
3 kW at 500...600 V AC 50/60 Hz AC-3e
3 kW at 660...690 V AC 50/60 Hz AC-3e
average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
Complementary
[ie] rated operational current 6 A at <= 440 V AC AC-3 for power circuit
6 A at <= 440 V AC AC-3e for power circuit
[ue] rated operational voltage Power circuit: 690 V AC 50/60 Hz
Signalling circuit: <= 690 V AC 50/60 Hz
[ics] rated service breaking capacity 110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
110 A at 220...230 V conforming to IEC 60947
110 A at 380...400 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
[icw] rated short-time withstand current 90 A 50 °C - 1 s for power circuit
85 A 50 °C - 5 s for power circuit
80 A 50 °C - 10 s for power circuit
60 A 50 °C - 30 s for power circuit
45 A 50 °C - 1 min for power circuit
40 A 50 °C - 3 min for power circuit
20 A 50 °C - >= 15 min for power circuit
80 A - 1 s for signalling circuit
90 A - 500 ms for signalling circuit
110 A - 100 ms for signalling circuit
[ith] conventional thermal current 20 A (at 50 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Product certifications CB Scheme
CCC
UL
CSA
EAC
CE
UKCA
Product or component type Contactor
tightening torque 0.8…1.3 N.m - on screw clamp terminals Philips No 2
0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm
0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
[uimp] rated impulse withstand voltage 8 kV
Auxiliary contact composition 1 NC
Connections - terminals Screw clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
minimum switching current 5 mA for signalling circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Auxiliary contacts type type instantaneous 1 NC
Device application Control
Control circuit voltage limits Operational: 0.85...1.1 Uc (at <50 °C)
Drop-out: 0.1...0.75 Uc (at <50 °C)
mechanical robustness Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Flame retardance V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Heat dissipation 3 W
Net weight 0.225 kg
Hold-in power consumption in va 3 VA (at 20 °C)
Mounting support Rail
Plate
depth 57 mm
Inrush power in va 3 VA (at 20 °C)
mechanical durability 10 Mcycles
electrical durability 1.3 Mcycles 6 A AC-3 at Ue <= 440 V
1.3 Mcycles 6 A AC-3e at Ue <= 440 V
Irms rated making capacity 110 A AC for power circuit conforming to NF C 63-110
110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Maximum operating rate 3600 cyc/h
operating time 30...40 ms coil energisation and NO closing
30 ms coil de-energisation and NO opening
minimum switching voltage 17 V for signalling circuit
Power pole contact composition 3 NO
Non overlap distance 0.5 mm
Poles description 3P
Utilisation category AC-4
AC-3
AC-3e
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Signalling circuit frequency <= 400 Hz
Environment
Ambient air temp for storage/transportation -50…80 °C
ip degree of protection IP2X conforming to VDE 0106
operating altitude 2000 m without derating
overvoltage category III
standards EN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
protective treatment TC conforming to IEC 60068
TC conforming to DIN 50016
insulation resistance > 10 MOhm for signalling circuit
About this product

The LC7K0601M7 - TeSys K contactor 3P AC3 <= 440 V 6 A 1 NC aux. 220...230 V AC coil is developed to address the obligations of professional purchasers, such as panel manufacturers, electric engineers, facility management firms, and industry fabricators. LC7K0601M7 offers unmatched excellence and asset for planners in the power systems industry. This TeSys K contactor 3P AC3 <= 440 V 6 A 1 NC aux. 220...230 V AC coil and other TeSyS K from Schneider Electric can be acquired at the most competitive price and shipment duration through BALTELEC website, an independent purveyor helping consultants in their supply needs.

Technicians who have procured Schneider Electric TeSyS K have commonly admired the creator's trustworthiness. It has been highlighted that the superior functionality of LC7K0601M7 - TeSys K contactor 3P AC3 <= 440 V 6 A 1 NC aux. 220...230 V AC coil extends to a spectrum of utilizations. Its premium properties make it great solution to suit a variety of needs. Your developed solution will excel in quality, energy-efficiency and price.

Our company dedicates in accommodating industrial and tertiary professionals’ needs. We comprehend the unique needs and anticipations of our buyers in the sector. By cooperating with our company, our partners secure access to the best rates and delivery period of first-rate products like LC7K0601M7 - TeSys K contactor 3P AC3 <= 440 V 6 A 1 NC aux. 220...230 V AC coil from Schneider Electric at the most competitive price. Baltelec account members take advantage of more savings and top-tier service.

Move quickly and grab LC7K0601M7 - TeSys K contactor 3P AC3 <= 440 V 6 A 1 NC aux. 220...230 V AC coil at our verified and hassle-free e-commerce site. Don't delay in making this sensible plan that warrants the greatest quality and covers the particular expectations of users like your team.

In case you have any doubts or concerns about LC7K0601M7 - TeSys K contactor 3P AC3 <= 440 V 6 A 1 NC aux. 220...230 V AC coil or any other Schneider Electric products, reach out to us or refer to our FAQs section below. We have amassed answers to recurring uncertainties to serve you further in making an enlightened decision about industrial and tertiary electrical components.

Remember, LC7K0601M7 - TeSys K contactor 3P AC3 <= 440 V 6 A 1 NC aux. 220...230 V AC coil from Schneider Electric is consistent, budget-friendly, and exceptional to its rivals in the TeSyS K category. Don't hesitate to make it a part of your network right now. Order at Baltelec e-shop, your consistent provider for all your TeSyS K.

In our Baltelec.eu virtual store you will come across TeSys K contactor 3P AC3 <= 440 V 6 A 1 NC aux. 220...230 V AC coil - LC7K0601M7 worth 72.73 €, which will be a safe and current solution for your desires. This goods is developed by the Schneider Electric brand using the newest technologies and adheres to the peak standards of precaution and efficacy. We present articles from the TeSyS K category that combine longevity and effectiveness, which is an first-rate pick for various tasks. Without consideration of whether you call for machinery for small manufacturing or for competent industrial exertion, TeSys K contactor 3P AC3 <= 440 V 6 A 1 NC aux. 220...230 V AC coil will be a secure companion in your job.

Baltelec attempts to make the attaining process as accessible and fast as achievable for our patrons. We offer detailed accounts and high-quality illustrations of TeSys K contactor 3P AC3 <= 440 V 6 A 1 NC aux. 220...230 V AC coil so that you can make an conscious choice. A team of connoisseurs is always ready to help you with any doubts in the TeSyS K section relevant to the selection and use of materials. We are assured that TeSys K contactor 3P AC3 <= 440 V 6 A 1 NC aux. 220...230 V AC coil will meet your demands and become an key element of your kit for just 72.73 €.

Common Questions about LC7K0601M7:

Recently viewed
LC7K0601M7 - Schneider Electric
TeSys K contactor 3P AC3 <= 440 V 6 A 1 NC aux. 220...230 V AC coil
59,62 € excl. VAT
73,92 € incl. VAT
Pending restock