SPECIFICATIONS
Main
Contactor application Motor control
Device short name LC2K
Interlocking type Mechanical
Range TeSys
[uc] control circuit voltage 230 V AC 50/60 Hz
Product Name TeSys K
[ui] rated insulation voltage Power circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Signalling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signalling circuit: 600 V conforming to CSA C22.2 No 14
control circuit type AC at 50/60 Hz
motor power kW 4 kW at 480 V AC 50/60 Hz
4 kW at 500...600 V AC 50/60 Hz
4 kW at 660...690 V AC 50/60 Hz
5.5 kW at 440 V AC 50/60 Hz
4 kW at 220...230 V AC 50/60 Hz
7.5 kW at 380...415 V AC 50/60 Hz
average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
Complementary
[ie] rated operational current 16 A at <= 440 V AC AC-3 for power circuit
16 A at <= 440 V AC AC-3e for power circuit
[ue] rated operational voltage Power circuit: 690 V AC 50/60 Hz
Signalling circuit: <= 690 V AC 50/60 Hz
[ics] rated service breaking capacity 110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
[icw] rated short-time withstand current 115 A 50 °C - 1 s for power circuit
105 A 50 °C - 5 s for power circuit
100 A 50 °C - 10 s for power circuit
75 A 50 °C - 30 s for power circuit
55 A 50 °C - 1 min for power circuit
50 A 50 °C - 3 min for power circuit
80 A - 1 s for signalling circuit
90 A - 500 ms for signalling circuit
110 A - 100 ms for signalling circuit
25 A 50 °C - >= 15 min for power circuit
[ith] conventional thermal current 20 A (at 50 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Product certifications CB Scheme
CCC
UL
CSA
EAC
CE
UKCA
Handle front plate colour 58 mm
Product or component type Reversing contactor
tightening torque 0.8…1.3 N.m - on screw clamp terminals Philips No 2
0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm
0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
[uimp] rated impulse withstand voltage 8 kV
Auxiliary contact composition 1 NO
Connections - terminals Screw clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
minimum switching current 5 mA for signalling circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Auxiliary contacts type type instantaneous 1 NO
Device application Control
Control circuit voltage limits Drop-out: 0.2...0.75 Uc (at <50 °C)
Operational: 0.85...1.15 Uc (at <50 °C)
width (w) 90 mm
mechanical robustness Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Flame retardance V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Heat dissipation 1.3 W
Net weight 0.39 kg
Hold-in power consumption in va 4.5 VA (at 20 °C)
Mounting support Rail
Plate
depth 57 mm
Inrush power in va 30 VA (at 20 °C)
mechanical durability 5 Mcycles
electrical durability 1.3 Mcycles 16 A AC-3 at Ue <= 440 V
1.3 Mcycles 16 A AC-3e at Ue <= 440 V
Device presentation Preassembled with reversing power busbar
Irms rated making capacity 160 A at 690 V AC for power circuit conforming to NF C 63-110
160 A at 690 V AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Maximum operating rate 3600 cyc/h
operating time 10...20 ms coil energisation and NO closing
10...20 ms coil de-energisation and NO opening
minimum switching voltage 17 V for signalling circuit
Power pole contact composition 3 NO
Non overlap distance 0.5 mm
Poles description 3P
Utilisation category AC-3
AC-4
AC-3e
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Signalling circuit frequency <= 400 Hz
Environment
Ambient air temp for storage/transportation -50…80 °C
ip degree of protection IP20 conforming to VDE 0106
operating altitude 2000 m without derating
ambient air temperature for operation -25…50 °C
overvoltage category III
standards EN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
protective treatment TC conforming to IEC 60068
TC conforming to DIN 50016
insulation resistance > 10 MOhm for signalling circuit
About this product

The LC2K1610P7 - TeSys K reversing contactor 3P AC3 <= 440 V 16 A 1 NO 230 V AC coil is designed to cover the desires of specialized professionals, such as panel builders, wiring experts, repair companies, and Original Equipment manufacturers. LC2K1610P7 furnishes superior excellence and worth for designers in the energy management industry. This TeSys K reversing contactor 3P AC3 <= 440 V 16 A 1 NO 230 V AC coil and other TeSyS K from Schneider Electric can be acquired at the finest pricing and supply period through baltelec.eu, a well-regarded retailer fulfilling the needs of contractors in their sourcing needs.

Customers who have adopted Schneider Electric TeSyS K have commonly acclaimed the creator's reliability. It has been pointed out that the outstanding energy-efficiency of LC2K1610P7 - TeSys K reversing contactor 3P AC3 <= 440 V 16 A 1 NO 230 V AC coil extends to a wide range of scenarios. Its supreme attributes make it fitting for various requirements, guaranteeing the success of your industrial, tertiary, and automation contracts.

Our team specializes in accommodating industrial and tertiary professionals’ needs. We recognize the special needs and requirements of our consumers in the niche. By joining forces with our professionals, your company obtain access to the leading pricing and supply timeline of the top-of-the-line products like LC2K1610P7 - TeSys K reversing contactor 3P AC3 <= 440 V 16 A 1 NO 230 V AC coil from Schneider Electric at an economical price. Our registered accounts appreciate exclusive discounts and dedicated support.

Don't wait and procure LC2K1610P7 - TeSys K reversing contactor 3P AC3 <= 440 V 16 A 1 NO 230 V AC coil at our verified and intuitive webshop. Don't delay in making this clever selection that certifies the superior quality and adheres to the customized requirements of users like your company.

If there are any inquiries or concerns about LC2K1610P7 - TeSys K reversing contactor 3P AC3 <= 440 V 16 A 1 NO 230 V AC coil or any other Schneider Electric products, drop us a line or refer to our Support section section below. We have compiled answers to frequent matters to advise you further in making an educated decision about industrial and tertiary electrical components.

Remember, LC2K1610P7 - TeSys K reversing contactor 3P AC3 <= 440 V 16 A 1 NO 230 V AC coil from Schneider Electric is consistent, value-priced, and high-quality to alternative suppliers in the TeSyS K category. Don't hesitate to make it a part of your network straight away. Take advantage of at baltele.eu, your steady distributor for all your Schneider Electric.

In our Baltelec.eu e-commerce store you will spot TeSys K reversing contactor 3P AC3 <= 440 V 16 A 1 NO 230 V AC coil - LC2K1610P7 worth 102.67 €, which will be a trustworthy and current solution for your wants. This thing is constructed by the Schneider Electric brand using the current technologies and obeys the optimal standards of well-being and workmanship. We propose produce from the TeSyS K category that associate lastingness and utility, which is an top-notch preference for various operations. In spite of whether you desire equipment for small manufacturing or for competent industrial use, TeSys K reversing contactor 3P AC3 <= 440 V 16 A 1 NO 230 V AC coil will be a reliable helper in your occupation.

Baltelec strives to make the attaining process as comfortable and fast as possible for our consumers. We offer detailed portrayals and high-quality depictions of TeSys K reversing contactor 3P AC3 <= 440 V 16 A 1 NO 230 V AC coil so that you can make an briefed choice. A team of specialists is always ready to help you with any issues in the TeSyS K section connected to the choosing and use of materials. We are convinced that TeSys K reversing contactor 3P AC3 <= 440 V 16 A 1 NO 230 V AC coil will meet your wishes and become an essential element of your machinery for just 102.67 €.

Common Questions about Schneider Electric TeSys K reversing contactor 3P AC3 <= 440 V 16 A 1 NO 230 V AC coil:

Recently viewed
LC2K1610P7 - Schneider Electric
TeSys K reversing contactor 3P AC3 <= 440 V 16 A 1 NO 230 V AC coil
84,16 € excl. VAT
104,36 € incl. VAT
Pending restock