SPECIFICATIONS
Main
Contactor application Resistive load
Motor control
Device short name LC2K
Interlocking type Mechanical
Range TeSys
[uc] control circuit voltage 110 V AC 50/60 Hz
Product Name TeSys K
[ui] rated insulation voltage Power circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Signalling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signalling circuit: 600 V conforming to CSA C22.2 No 14
control circuit type AC at 50/60 Hz
motor power kW 4 kW at 480 V AC 50/60 Hz
4 kW at 500...600 V AC 50/60 Hz
4 kW at 660...690 V AC 50/60 Hz
3 kW at 220...230 V AC 50/60 Hz
5.5 kW at 380...415 V AC 50/60 Hz
5.5 kW at 440 V AC 50/60 Hz
average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
Complementary
[ie] rated operational current 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit
16 A (at <70 °C) at 690 V AC AC-1 for power circuit
12 A at <= 440 V AC AC-3 for power circuit
12 A at <= 440 V AC AC-3e for power circuit
[ue] rated operational voltage Power circuit: 690 V AC 50/60 Hz
Signalling circuit: <= 690 V AC 50/60 Hz
[ics] rated service breaking capacity 110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
[icw] rated short-time withstand current 115 A 50 °C - 1 s for power circuit
105 A 50 °C - 5 s for power circuit
100 A 50 °C - 10 s for power circuit
75 A 50 °C - 30 s for power circuit
55 A 50 °C - 1 min for power circuit
50 A 50 °C - 3 min for power circuit
80 A - 1 s for signalling circuit
90 A - 500 ms for signalling circuit
110 A - 100 ms for signalling circuit
25 A 50 °C - >= 15 min for power circuit
[ith] conventional thermal current 20 A (at 50 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Product certifications CB Scheme
CCC
UL
CSA
EAC
CE
UKCA
Handle front plate colour 58 mm
Product or component type Reversing contactor
tightening torque 0.8…1.3 N.m - on screw clamp terminals Philips No 2
0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm
0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
[uimp] rated impulse withstand voltage 8 kV
Auxiliary contact composition 1 NO
Connections - terminals Screw clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
minimum switching current 5 mA for signalling circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Auxiliary contacts type type instantaneous 1 NO
Device application Control
Control circuit voltage limits Operational: 0.8...1.15 Uc (at <50 °C)
Drop-out: 0.2...0.75 Uc (at <50 °C)
width (w) 90 mm
mechanical robustness Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Flame retardance V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Heat dissipation 1.3 W
Net weight 0.39 kg
Hold-in power consumption in va 4.5 VA (at 20 °C)
Mounting support Rail
Plate
depth 57 mm
Inrush power in va 30 VA (at 20 °C)
mechanical durability 5 Mcycles
electrical durability 0.3 Mcycles 20 A AC-1 at Ue <= 440 V
1.3 Mcycles 12 A AC-3 at Ue <= 440 V
Device presentation Preassembled with reversing power busbar
Irms rated making capacity 144 A at 690 V AC for power circuit conforming to NF C 63-110
144 A at 690 V AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Maximum operating rate 3600 cyc/h
operating time 10...20 ms coil energisation and NO closing
10...20 ms coil de-energisation and NO opening
minimum switching voltage 17 V for signalling circuit
Power pole contact composition 3 NO
Non overlap distance 0.5 mm
Poles description 3P
Utilisation category AC-3
AC-4
AC-1
AC-3e
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Signalling circuit frequency <= 400 Hz
Environment
Ambient air temp for storage/transportation -50…80 °C
ip degree of protection IP20 conforming to VDE 0106
operating altitude 2000 m without derating
ambient air temperature for operation -25…50 °C
overvoltage category III
standards EN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
protective treatment TC conforming to IEC 60068
TC conforming to DIN 50016
insulation resistance > 10 MOhm for signalling circuit
About this product

The LC2K1210F7 - TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NO 110 V AC coil is developed to satisfy the conditions of trade professionals, such as circuit designers, circuit experts, service organizations, and Industry suppliers. LC2K1210F7 supplies outstanding efficiency and asset for engineers in the electrical and automation industry. This TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NO 110 V AC coil and other TeSyS K from Schneider Electric are on offer the best price and shipment duration through BaltElec website, a well-known provider assisting experts in their provision needs.

Professionals who have procured Schneider Electric TeSyS K have invariably applauded the manufacturer’s sturdiness. It has been stated that the notable effectiveness of LC2K1210F7 - TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NO 110 V AC coil extends to a array of deployments. Its superior elements make it suitable to satisfy a wide array of needs, promoting success in your industrial, tertiary, and automation efforts.

Our experts devotes in catering industrial and tertiary professionals’ needs. We get the specific specifications and desires of our partners in the niche. By partnering with our specialists, our customers receive access to the top price lists and delivery period of first-rate products like LC2K1210F7 - TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NO 110 V AC coil from Schneider Electric at cost-effective price. Professional buyers with Baltelec account enjoy special savings and top-tier service.

Don't wait and purchase LC2K1210F7 - TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NO 110 V AC coil at our certified and streamlined website. Don't delay in making this astute investment that promises the best quality and achieves the personalized criteria of clients like your team.

If you encounter any uncertainties or concerns about LC2K1210F7 - TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NO 110 V AC coil or any other Schneider Electric products, connect with us or refer to our Frequently Asked Queries section below. We have assembled answers to recurring concerns to guide you further in making an educated decision about industrial and tertiary electrical components.

Remember, LC2K1210F7 - TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NO 110 V AC coil from Schneider Electric is credible, affordable, and top-notch to its competitors in the TeSyS K category. Feel free to make it a part of your installation instantly. Shop with confidence at baltele.eu, your faithful dealer for all your TeSyS K.

In our Baltelec.eu virtual store you will locate TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NO 110 V AC coil - LC2K1210F7 worth 82.94 €, which will be a faithful and up-to-date solution for your expectations. This product is invented by the Schneider Electric brand using the current technologies and fulfills the maximum standards of assurance and efficiency. We present commodities from the TeSyS K category that associate robustness and workability, which is an excellent selection for various uses. Independent of whether you call for equipment for small formation or for competent industrial purpose, TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NO 110 V AC coil will be a faithful aide in your duty.

Baltelec tries to make the shopping process as smooth and fast as accomplishable for our patrons. We offer detailed descriptions and high-quality pictures of TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NO 110 V AC coil so that you can make an educated choice. A team of experts is always ready to help you with any issues in the TeSyS K section affiliated to the selection and use of supplies. We are trusting that TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NO 110 V AC coil will meet your wishes and become an crucial element of your device for just 82.94 €.

Popular Questions about Schneider Electric TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NO 110 V AC coil:

Recently viewed
LC2K1210F7 - Schneider Electric
TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NO 110 V AC coil
67,99 € excl. VAT
84,30 € incl. VAT
Pending restock