SPECIFICATIONS
Main
Contactor application Resistive load
Motor control
Device short name LC2K
Interlocking type Mechanical
Range TeSys
[uc] control circuit voltage 110 V AC 50/60 Hz
Product Name TeSys K
[ui] rated insulation voltage Power circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Signalling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signalling circuit: 600 V conforming to CSA C22.2 No 14
control circuit type AC at 50/60 Hz
motor power kW 4 kW at 480 V AC 50/60 Hz
4 kW at 500...600 V AC 50/60 Hz
4 kW at 660...690 V AC 50/60 Hz
3 kW at 220...230 V AC 50/60 Hz
5.5 kW at 380...415 V AC 50/60 Hz
5.5 kW at 440 V AC 50/60 Hz
average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
Complementary
[ie] rated operational current 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit
16 A (at <70 °C) at 690 V AC AC-1 for power circuit
12 A at <= 440 V AC AC-3 for power circuit
12 A at <= 440 V AC AC-3e for power circuit
[ue] rated operational voltage Power circuit: 690 V AC 50/60 Hz
Signalling circuit: <= 690 V AC 50/60 Hz
[ics] rated service breaking capacity 110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
[icw] rated short-time withstand current 115 A 50 °C - 1 s for power circuit
105 A 50 °C - 5 s for power circuit
100 A 50 °C - 10 s for power circuit
75 A 50 °C - 30 s for power circuit
55 A 50 °C - 1 min for power circuit
50 A 50 °C - 3 min for power circuit
80 A - 1 s for signalling circuit
90 A - 500 ms for signalling circuit
110 A - 100 ms for signalling circuit
25 A 50 °C - >= 15 min for power circuit
[ith] conventional thermal current 20 A (at 50 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Product certifications CB Scheme
CCC
UL
CSA
EAC
CE
UKCA
Handle front plate colour 58 mm
Product or component type Reversing contactor
tightening torque 0.8…1.3 N.m - on screw clamp terminals Philips No 2
0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm
0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
[uimp] rated impulse withstand voltage 8 kV
Auxiliary contact composition 1 NC
Connections - terminals Screw clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
minimum switching current 5 mA for signalling circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Auxiliary contacts type type instantaneous 1 NC
Device application Control
Control circuit voltage limits Operational: 0.8...1.15 Uc (at <50 °C)
Drop-out: 0.2...0.75 Uc (at <50 °C)
width (w) 90 mm
mechanical robustness Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Flame retardance V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Heat dissipation 1.3 W
Net weight 0.39 kg
Hold-in power consumption in va 4.5 VA (at 20 °C)
Mounting support Plate
Rail
depth 57 mm
Inrush power in va 30 VA (at 20 °C)
mechanical durability 5 Mcycles
electrical durability 0.3 Mcycles 20 A AC-1 at Ue <= 440 V
1.3 Mcycles 12 A AC-3 at Ue <= 440 V
1.3 Mcycles 12 A AC-3e at Ue <= 440 V
Device presentation Preassembled with reversing power busbar
Irms rated making capacity 144 A at 690 V AC for power circuit conforming to NF C 63-110
144 A at 690 V AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Maximum operating rate 3600 cyc/h
operating time 10...20 ms coil energisation and NO closing
10...20 ms coil de-energisation and NO opening
minimum switching voltage 17 V for signalling circuit
Power pole contact composition 3 NO
Non overlap distance 0.5 mm
Poles description 3P
Utilisation category AC-3
AC-4
AC-1
AC-3e
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Signalling circuit frequency <= 400 Hz
Environment
Ambient air temp for storage/transportation -50…80 °C
ip degree of protection IP20 conforming to VDE 0106
operating altitude 2000 m without derating
ambient air temperature for operation -25…50 °C
overvoltage category III
standards EN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
protective treatment TC conforming to IEC 60068
TC conforming to DIN 50016
insulation resistance > 10 MOhm for signalling circuit
About this product

The LC2K1201F7 - TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NC 110 V AC coil is produced to cater to the desires of trade buyers, such as electrical contractors, electricians, service organizations, and industry fabricators. LC2K1201F7 dispenses extraordinary integrity and asset for contractors in the power systems industry. This TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NC 110 V AC coil and other TeSyS K from Schneider Electric can be purchased at the most affordable rate and delivery schedule through baltelec.eu, a reliable reseller helping technicians in their supply needs.

Users who have acquired Schneider Electric TeSyS K have invariably admired the maker's trustworthiness. It has been pointed out that the superlative productivity of LC2K1201F7 - TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NC 110 V AC coil extends to a extensive scope of applications. Its first-rate attributes make it well-suited solution to satisfy a wide array of needs, assuring the success of your industrial, tertiary, and automation ventures.

Our specialists centers in meeting industrial and tertiary professionals’ needs. We appreciate the specific demands and requirements of our stakeholders in the realm. By teaming up with our experts, your team access access to the best costs and stock of top-tier products like LC2K1201F7 - TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NC 110 V AC coil from Schneider Electric at an economical price. Our registered accounts receive exclusive discounts and first-class attention.

Do not hesitate and grab LC2K1201F7 - TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NC 110 V AC coil at our dependable and accessible internet shop. Don't delay in making this shrewd move that warrants the superior quality and adheres to the unique specifications of vendors like yourselves.

In case you have any concerns or concerns about LC2K1201F7 - TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NC 110 V AC coil or any other Schneider Electric products, connect with us or refer to our Common Questions section below. We have consolidated answers to usual inquiries to serve you further in making an thoughtful decision about industrial and tertiary electrical components.

Remember, LC2K1201F7 - TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NC 110 V AC coil from Schneider Electric is dependable, economical, and better to its competitors in the TeSyS K category. Feel free to make it a part of your installation instantly. Acquire at Baltelec e-shop, your steady distributor for all your TeSyS K.

In our Baltelec.eu digital store you will locate TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NC 110 V AC coil - LC2K1201F7 worth 82.94 €, which will be a safe and up-to-date solution for your requirements. This commodity is fabricated by the Schneider Electric brand using the advanced technologies and satisfies the top standards of well-being and competence. We propose products from the TeSyS K category that combine longevity and operability, which is an fine election for various applications. Without consideration of whether you desire apparatus for small fabrication or for experienced industrial implementation, TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NC 110 V AC coil will be a dependable aide in your duty.

Baltelec aims to make the securing process as simple and fast as attainable for our customers. We offer detailed descriptions and high-quality images of TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NC 110 V AC coil so that you can make an briefed choice. A team of masters is always ready to help you with any issues in the TeSyS K section related to the choosing and use of equipment. We are certain that TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NC 110 V AC coil will meet your anticipations and become an crucial element of your kit for just 82.94 €.

Common Queries about LC2K1201F7:

Recently viewed
LC2K1201F7 - Schneider Electric
TeSys K reversing contactor 3P AC3 <= 440 V 12 A 1 NC 110 V AC coil
67,99 € excl. VAT
84,30 € incl. VAT
Pending restock