SPECIFICATIONS
Main
Contactor application Resistive load
Motor control
Device short name LC2K
Interlocking type Mechanical
Range TeSys
[uc] control circuit voltage 120 V AC 50/60 Hz
Product Name TeSys K
[ui] rated insulation voltage Power circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Signalling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signalling circuit: 600 V conforming to CSA C22.2 No 14
control circuit type AC at 50/60 Hz
motor power kW 2.2 kW at 220...230 V AC 50/60 Hz
4 kW at 380...415 V AC 50/60 Hz
4 kW at 440 V AC 50/60 Hz
4 kW at 480 V AC 50/60 Hz
4 kW at 500...600 V AC 50/60 Hz
4 kW at 660...690 V AC 50/60 Hz
average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
Complementary
[ie] rated operational current 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit
16 A (at <70 °C) at 690 V AC AC-1 for power circuit
9 A at <= 440 V AC AC-3 for power circuit
9 A at <= 440 V AC AC-3e for power circuit
[ue] rated operational voltage Power circuit: 690 V AC 50/60 Hz
Signalling circuit: <= 690 V AC 50/60 Hz
[ics] rated service breaking capacity 110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
110 A at 220...230 V conforming to IEC 60947
110 A at 380...400 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
[icw] rated short-time withstand current 90 A 50 °C - 1 s for power circuit
85 A 50 °C - 5 s for power circuit
80 A 50 °C - 10 s for power circuit
60 A 50 °C - 30 s for power circuit
45 A 50 °C - 1 min for power circuit
40 A 50 °C - 3 min for power circuit
80 A - 1 s for signalling circuit
90 A - 500 ms for signalling circuit
110 A - 100 ms for signalling circuit
20 A 50 °C - >= 15 min for power circuit
[ith] conventional thermal current 20 A (at 50 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Product certifications CB Scheme
CCC
UL
CSA
EAC
CE
UKCA
Handle front plate colour 58 mm
Product or component type Reversing contactor
tightening torque 0.8…1.3 N.m - on screw clamp terminals Philips No 2
0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm
0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
[uimp] rated impulse withstand voltage 8 kV
Auxiliary contact composition 1 NC
Connections - terminals Screw clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
minimum switching current 5 mA for signalling circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Auxiliary contacts type type instantaneous 1 NC
Device application Control
Control circuit voltage limits Operational: 0.8...1.15 Uc (at <50 °C)
Drop-out: 0.2...0.75 Uc (at <50 °C)
width (w) 90 mm
mechanical robustness Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Flame retardance V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Heat dissipation 1.3 W
Net weight 0.39 kg
Hold-in power consumption in va 4.5 VA (at 20 °C)
Mounting support Plate
Rail
depth 57 mm
Inrush power in va 30 VA (at 20 °C)
mechanical durability 5 Mcycles
electrical durability 0.18 Mcycles 20 A AC-1 at Ue <= 440 V
1.3 Mcycles 9 A AC-3 at Ue <= 440 V
1.3 Mcycles 9 A AC-3e at Ue <= 440 V
Device presentation Preassembled with reversing power busbar
Irms rated making capacity 110 A AC for power circuit conforming to NF C 63-110
110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Maximum operating rate 3600 cyc/h
operating time 10...20 ms coil energisation and NO closing
10...20 ms coil de-energisation and NO opening
minimum switching voltage 17 V for signalling circuit
Power pole contact composition 3 NO
Non overlap distance 0.5 mm
Poles description 3P
Utilisation category AC-1
AC-3
AC-4
AC-3e
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Signalling circuit frequency <= 400 Hz
Environment
Ambient air temp for storage/transportation -50…80 °C
ip degree of protection IP20 conforming to VDE 0106
operating altitude 2000 m without derating
ambient air temperature for operation -25…50 °C
overvoltage category III
standards EN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
protective treatment TC conforming to IEC 60068
TC conforming to DIN 50016
insulation resistance > 10 MOhm for signalling circuit
About this product

The LC2K0901G7 - TeSys K reversing contactor 3P AC3 <= 440 V 9 A 1 NC 120 V AC coil is engineered to meet the needs of trade professionals, such as circuit designers, circuit experts, upkeep firms, and original producers. LC2K0901G7 yields extraordinary excellence and merit for contractors in the electrical engineering industry. This TeSys K reversing contactor 3P AC3 <= 440 V 9 A 1 NC 120 V AC coil and other TeSyS K from Schneider Electric are in stock at the most advantageous pricing and lead time through BaltElec online store, a reputable retailer attending to industry experts in their supply needs.

Customers who have used Schneider Electric TeSyS K have continuously lauded the creator's trustworthiness. It has been noted that the outstanding productivity of LC2K0901G7 - TeSys K reversing contactor 3P AC3 <= 440 V 9 A 1 NC 120 V AC coil extends to a multitude of purposes. Its superior traits make it well-suited solution for assorted uses, assuring the success of your industrial, tertiary, and automation ventures.

Our experts centers in addressing industrial and tertiary professionals’ needs. We understand the individual needs and expectations of our patrons in the field. By cooperating with BALTELEC, your organization get access to the optimal pricing and delivery period of top-tier products like LC2K0901G7 - TeSys K reversing contactor 3P AC3 <= 440 V 9 A 1 NC 120 V AC coil from Schneider Electric at cost-effective price. Baltelec account members appreciate further discounts and preferred assistance.

Take action and procure LC2K0901G7 - TeSys K reversing contactor 3P AC3 <= 440 V 9 A 1 NC 120 V AC coil at our dependable and straightforward web store. Don't delay in making this thoughtful move that secures the ultimate quality and meets the particular expectations of customers like your outfit.

If you encounter any inquiries or concerns about LC2K0901G7 - TeSys K reversing contactor 3P AC3 <= 440 V 9 A 1 NC 120 V AC coil or any other Schneider Electric products, communicate with us or refer to our Knowledge base section below. We have curated answers to standard questions to benefit you further in making an educated decision about industrial and tertiary electrical components.

Remember, LC2K0901G7 - TeSys K reversing contactor 3P AC3 <= 440 V 9 A 1 NC 120 V AC coil from Schneider Electric is steady, thrifty, and top-notch to its competitors in the TeSyS K category. Don't hesitate to make it a part of your solution instantly. Acquire at baltele.eu, your consistent provider for all your professional electrical equipment and automation needs.

In our Baltelec.eu digital store you will uncover TeSys K reversing contactor 3P AC3 <= 440 V 9 A 1 NC 120 V AC coil - LC2K0901G7 worth 122.88 €, which will be a constant and new solution for your preferences. This goods is designed by the Schneider Electric brand using the advanced technologies and aligns with the optimal standards of safety and competence. We extend items from the TeSyS K category that mix sturdiness and efficacy, which is an top-notch choice for various uses. Not minding of whether you call for machinery for small fabrication or for experienced industrial use, TeSys K reversing contactor 3P AC3 <= 440 V 9 A 1 NC 120 V AC coil will be a secure aid in your duty.

Baltelec efforts to make the shopping process as manageable and fast as realizable for our users. We offer detailed depictions and high-quality shots of TeSys K reversing contactor 3P AC3 <= 440 V 9 A 1 NC 120 V AC coil so that you can make an informed choice. A team of adepts is always ready to help you with any issues in the TeSyS K section involved to the electing and use of products. We are convinced that TeSys K reversing contactor 3P AC3 <= 440 V 9 A 1 NC 120 V AC coil will meet your prospects and become an key element of your device for just 122.88 €.

Customer Queries about LC2K0901G7 - TeSys K reversing contactor 3P AC3 <= 440 V 9 A 1 NC 120 V AC coil:

Recently viewed
LC2K0901G7 - Schneider Electric
TeSys K reversing contactor 3P AC3 <= 440 V 9 A 1 NC 120 V AC coil
100,72 € excl. VAT
124,89 € incl. VAT
Expected in 2-4 weeks