All categories
Compare Cart

LC2D25KUE - TeSys Deca reversing contactor 3P <= 440 V 25 A AC3 100...250 V AC/DC coil - Schneider Electric

Pending restock
LC2D25KUE - TeSys Deca reversing contactor 3P <= 440 V 25 A AC3 100...250 V AC/DC coil - Schneider Electric - TeSys Deca reversing contactor 3P <= 440 V 25 A AC3 100...250 V AC/DC coil - Schneider Electric - 0
LC2D25KUE - TeSys Deca reversing contactor 3P <= 440 V 25 A AC3 100...250 V AC/DC coil - Schneider Electric
244,30 € excl. VAT
302,93 € incl. VAT
Text About:
TeSys Deca reversing contactor 3P <= 440 V 25 A AC3 100...250 V AC/DC coil - Schneider Electric
302,93 €
SPECIFICATIONS
Main
Contactor application Resistive load
Motor control
Device short name LC2D
Interlocking type Mechanical
Range TeSys
TeSys Deca
[uc] control circuit voltage 100...250 V AC 50/60 Hz
100...250 V DC
Front cover With
Product Name TeSys D Green
TeSys Deca
Motor power hp (ul / csa) 2 hp at 115 V AC 60 Hz for 1 phase motors
3 hp at 230/240 V AC 60 Hz for 1 phase motors
7.5 hp at 200/208 V AC 60 Hz for 3 phases motors
7.5 hp at 230/240 V AC 60 Hz for 3 phases motors
15 hp at 460/480 V AC 60 Hz for 3 phases motors
20 hp at 575/600 V AC 60 Hz for 3 phases motors
[ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-1
control circuit type AC at 50/60 Hz AC/DC electronic
DC AC/DC electronic
motor power kW 5.5 kW at 220...230 V AC 50 Hz
11 kW at 380...400 V AC 50 Hz
11 kW at 415 V AC 50 Hz
11 kW at 440 V AC 50 Hz
15 kW at 500 V AC 50 Hz
15 kW at 660...690 V AC 50 Hz
average impedance 2 mOhm - Ith 40 A 50 Hz for power circuit
Complementary
[ie] rated operational current 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
[ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
[ics] rated service breaking capacity 450 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current 50 A 40 °C - 10 min for power circuit
120 A 40 °C - 1 min for power circuit
240 A 40 °C - 10 s for power circuit
380 A 40 °C - 1 s for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
[ith] conventional thermal current 10 A (at 60 °C) for signalling circuit
40 A (at 60 °C) for power circuit
Product certifications CCC
CSA
EAC
UL
KC
DNV-GL
LROS (Lloyds register of shipping)
UKCA
Handle front plate colour 85 mm
Product or component type Reversing contactor
tightening torque Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Control circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Auxiliary contact composition 1 NO + 1 NC
Connections - terminals Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid
Power circuit: screw clamp terminals 1 cable(s) 2.5…10 mm²flexible without cable end
Power circuit: screw clamp terminals 2 cable(s) 2.5…10 mm²flexible without cable end
Power circuit: screw clamp terminals 1 cable(s) 1…10 mm²flexible with cable end
Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm²flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm²solid
Power circuit: screw clamp terminals 2 cable(s) 2.5…10 mm²solid
minimum switching current 5 mA for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
63 A gG at <= 690 V coordination type 1 for power circuit
40 A gG at <= 690 V coordination type 2 for power circuit
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Control circuit voltage limits <= 0.1 Uc (-40…70 °C):drop-out AC/DC
0.85...1.1 Uc (-40…60 °C):operational AC/DC
1...1.1 Uc (60…70 °C):operational AC/DC
width (w) 90 mm
mechanical robustness Vibrations contactor open: 2 Gn, 5...300 Hz
Vibrations contactor closed: 4 Gn, 5...300 Hz
Shocks contactor closed: 15 Gn for 11 ms
Shocks contactor open: 8 Gn for 11 ms
Colour Grey (SE GREY 6)
Green (SE GREEN 2)
Flame retardance V1 conforming to UL 94
Heat dissipation 1.1 W at 50/60 Hz
Net weight 0.913 kg
Hold-in power consumption in va 1.6 VA (at 20 °C) 50/60 Hz
Hold-in power consumption in w 1.1 W at 20 °C
Mounting support Rail
Plate
power dissipation per pole 3.2 W AC-1
1.25 W AC-3
depth 92 mm
Inrush power in va 25 VA 50/60 Hz (at 20 °C)
inrush power in w 18 W at 20 °C
mechanical durability 15 Mcycles
electrical durability 2 Mcycles 21 A AC-3 at Ue <= 440 V
0.9 Mcycles 40 A AC-1 at Ue <= 440 V
Device presentation Preassembled with reversing power busbar
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
450 A at 440 V for power circuit conforming to IEC 60947
Pollution degree 3
Maximum operating rate 3600 cyc/h 60 °C
operating time 45...55 ms closing
20...90 ms opening
minimum switching voltage 17 V for signalling circuit
Power pole contact composition 3 NO
non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
coil technology Built-in bidirectional peak limiting
Poles description 3P
Utilisation category AC-1
AC-3
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Signalling circuit frequency 25...400 Hz
Environment
Ambient air temp for storage/transportation -60…80 °C
Climatic withstand conforming to IACS E10
conforming to IEC 60947-1 Annex Q category D
ip degree of protection IP20 front face conforming to IEC 60529
operating altitude 0...3000 m
ambient air temperature for operation -40…60 °C
60…70 °C with derating
overvoltage category III
standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
IEC 60335-1
fire resistance 850 °C conforming to IEC 60695-2-1
protective treatment TH conforming to IEC 60068-2-30
insulation resistance > 10 MOhm for signalling circuit
About this product

The LC2D25KUE - TeSys Deca reversing contactor 3P <= 440 V 25 A AC3 100...250 V AC/DC coil is developed to address the desires of professional buyers, such as system integrators, electricians, service providers, and original manufacturers. LC2D25KUE grants outstanding capability and utility for specialists in the electrical engineering industry. This TeSys Deca reversing contactor 3P <= 440 V 25 A AC3 100...250 V AC/DC coil and other TeSyS Deca Contactors from Schneider Electric are in stock at the most economical price and delivery schedule through BaltElec online store, a well-regarded reseller supplying practitioners in their collection needs.

Professionals who have opted for Schneider Electric TeSyS Deca Contactors have regularly appreciated the producer's sturdiness. It has been emphasized that the remarkable operation of LC2D25KUE - TeSys Deca reversing contactor 3P <= 440 V 25 A AC3 100...250 V AC/DC coil extends to a wide range of purposes. Its ideal qualities make it appropriate to meet diverse demands, assuring the success of your industrial, tertiary, and automation ventures.

Our specialists dedicates in fulfilling industrial and tertiary professionals’ needs. We appreciate the individual specifications and requirements of our buyers in the niche. By cooperating with our professionals, our partners receive access to the optimal price and lead time of high-quality products like LC2D25KUE - TeSys Deca reversing contactor 3P <= 440 V 25 A AC3 100...250 V AC/DC coil from Schneider Electric at an affordable price. Baltelec account members take advantage of additional savings and expedited requests handling.

Move quickly and acquire LC2D25KUE - TeSys Deca reversing contactor 3P <= 440 V 25 A AC3 100...250 V AC/DC coil at our reliable and easy-to-use website. Don't delay in making this thoughtful move that confirms the top quality and satisfies the targeted criteria of traders like your business.

If there are any problems or concerns about LC2D25KUE - TeSys Deca reversing contactor 3P <= 440 V 25 A AC3 100...250 V AC/DC coil or any other Schneider Electric products, get in touch with us or refer to our Support section section below. We have compiled answers to frequent questions to assist you further in making an well-considered decision about industrial and tertiary electrical components.

Remember, LC2D25KUE - TeSys Deca reversing contactor 3P <= 440 V 25 A AC3 100...250 V AC/DC coil from Schneider Electric is credible, cost-effective, and premier to its rivals in the TeSyS Deca Contactors category. Don't hesitate to make it a part of your electrical system now. Snap up at baltele.eu, your preferred supplier for all your professional electrical equipment and automation needs.

In our Baltelec.eu internet store you will encounter TeSys Deca reversing contactor 3P <= 440 V 25 A AC3 100...250 V AC/DC coil - LC2D25KUE worth 298.04 €, which will be a trustworthy and contemporary solution for your wishes. This goods is produced by the Schneider Electric brand using the advanced technologies and fulfills the premier standards of safety and effectiveness. We furnish things from the TeSyS Deca Contactors category that merge robustness and effectiveness, which is an exceptional choice for various objectives. Without consideration of whether you demand equipment for small creation or for skilled industrial employment, TeSys Deca reversing contactor 3P <= 440 V 25 A AC3 100...250 V AC/DC coil will be a faithful helper in your assignment.

Baltelec labors to make the purchasing process as easy and fast as feasible for our shoppers. We offer detailed descriptions and high-quality photographs of TeSys Deca reversing contactor 3P <= 440 V 25 A AC3 100...250 V AC/DC coil so that you can make an informed choice. A team of authorities is always ready to help you with any enquiries in the TeSyS Deca Contactors section relevant to the choosing and use of products. We are positive that TeSys Deca reversing contactor 3P <= 440 V 25 A AC3 100...250 V AC/DC coil will meet your demands and become an crucial element of your gear for just 298.04 €.

Common Queries about LC2D25KUE - TeSys Deca reversing contactor 3P <= 440 V 25 A AC3 100...250 V AC/DC coil:

Recently viewed
LC2D25KUE - Schneider Electric
TeSys Deca reversing contactor 3P <= 440 V 25 A AC3 100...250 V AC/DC coil
244,30 € excl. VAT
302,93 € incl. VAT
Pending restock