LC1K1601B7 - TeSys K contactor 3P AC3 <= 440 V 16 A 1 NC aux. 24 V AC coil - Schneider Electric

Expected in 2-4 weeks
LC1K1601B7 - TeSys K contactor 3P AC3 <= 440 V 16 A 1 NC aux. 24 V AC coil - Schneider Electric - TeSys K contactor 3P AC3 <= 440 V 16 A 1 NC aux. 24 V AC coil - Schneider Electric - 0
LC1K1601B7 - TeSys K contactor 3P AC3 <= 440 V 16 A 1 NC aux. 24 V AC coil - Schneider Electric
37,18 € excl. VAT
45,36 € incl. VAT
Text About:
TeSys K contactor 3P AC3 <= 440 V 16 A 1 NC aux. 24 V AC coil - Schneider Electric
45,36 €
SPECIFICATIONS
Main
Contactor application Motor control
Device short name LC1K
Range TeSys
[uc] control circuit voltage 24 V AC 50/60 Hz
Product Name TeSys K
[ui] rated insulation voltage Power circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Signalling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signalling circuit: 600 V conforming to CSA C22.2 No 14
control circuit type AC at 50/60 Hz
motor power kW 4 kW at 480 V AC 50/60 Hz
4 kW at 500...600 V AC 50/60 Hz
4 kW at 660...690 V AC 50/60 Hz
5.5 kW at 440 V AC 50/60 Hz
4 kW at 220...230 V AC 50/60 Hz
7.5 kW at 380...415 V AC 50/60 Hz
average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
Complementary
[ie] rated operational current 16 A at <= 440 V AC-3 for power circuit
20 A at <= 690 V AC-1 for power circuit
16 A at <= 440 V AC-3e for power circuit
[ue] rated operational voltage Power circuit: 690 V AC 50/60 Hz
Signalling circuit: 690 V AC 50/60 Hz
[ics] rated service breaking capacity 110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
[icw] rated short-time withstand current 115 A 50 °C - 1 s for power circuit
105 A 50 °C - 5 s for power circuit
100 A 50 °C - 10 s for power circuit
75 A 50 °C - 30 s for power circuit
55 A 50 °C - 1 min for power circuit
50 A 50 °C - 3 min for power circuit
25 A 50 °C - >= 15 min for power circuit
80 A - 1 s for signalling circuit
90 A - 500 ms for signalling circuit
110 A - 100 ms for signalling circuit
[ith] conventional thermal current 20 A (at 50 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Product certifications CB Scheme
CCC
UL
CSA
EAC
CE
UKCA
Handle front plate colour 58 mm
Product or component type Contactor
tightening torque 0.8…1.3 N.m - on screw clamp terminals Philips No 2
0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm
0.8…1.3 N.m - on lugs-ring terminals pozidriv No 2
[uimp] rated impulse withstand voltage 8 kV
Auxiliary contact composition 1 NC
Connections - terminals Screw clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
minimum switching current 5 mA for signalling circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Auxiliary contacts type type instantaneous 1 NC
Device application Control
Control circuit voltage limits Operational: 0.8...1.15 Uc (at <50 °C)
Drop-out: 0.2...0.75 Uc (at <50 °C)
width (w) 45 mm
mechanical robustness Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Flame retardance V1 conforming to UL 94
Heat dissipation 1.3 W
Net weight 0.18 kg
Hold-in power consumption in va 4.5 VA (at 20 °C)
Mounting support Rail
Plate
depth 57 mm
Inrush power in va 30 VA (at 20 °C)
mechanical durability 10 Mcycles
electrical durability 1.3 Mcycles 16 A AC-3 at Ue <= 440 V
1.3 Mcycles 16 A AC-3e at Ue <= 440 V
Irms rated making capacity 110 A AC for signalling circuit conforming to IEC 60947
160 A AC for power circuit conforming to NF C 63-110
160 A AC for power circuit conforming to IEC 60947
Maximum operating rate 3600 cyc/h
operating time 10...20 ms coil de-energisation and NO opening
10...20 ms coil energisation and NO closing
minimum switching voltage 17 V for signalling circuit
Power pole contact composition 3 NO
Non overlap distance 0.5 mm
Poles description 3P
Utilisation category AC-3
AC-1
AC-3e
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Signalling circuit frequency <= 400 Hz
Environment
Ambient air temp for storage/transportation -50…80 °C
ip degree of protection IP2X conforming to VDE 0106
operating altitude 2000 m without derating
ambient air temperature for operation -25…50 °C
overvoltage category III
standards EN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
protective treatment TC conforming to IEC 60068
TC conforming to DIN 50016
insulation resistance > 10 MOhm for signalling circuit