All categories
Compare Cart

LC1K0910Q7 - TeSys K contactor 3P AC3 <= 440 V 9 A 1 NO aux. 380...400 V AC coil - Schneider Electric

Expected in 2-4 weeks
LC1K0910Q7 - TeSys K contactor 3P AC3 <= 440 V 9 A 1 NO aux. 380...400 V AC coil - Schneider Electric - TeSys K contactor 3P AC3 <= 440 V 9 A 1 NO aux. 380...400 V AC coil - Schneider Electric - 0
LC1K0910Q7 - TeSys K contactor 3P AC3 <= 440 V 9 A 1 NO aux. 380...400 V AC coil - Schneider Electric
26,87 € excl. VAT
32,78 € incl. VAT
Text About:
TeSys K contactor 3P AC3 <= 440 V 9 A 1 NO aux. 380...400 V AC coil - Schneider Electric
32,78 €
SPECIFICATIONS
Main
Contactor application Motor control
Resistive load
Range TeSys
[uc] control circuit voltage 380...400 V AC 50/60 Hz
Product Name TeSys K
control circuit type AC at 50/60 Hz
motor power kW 2.2 kW at 220...230 V AC 50/60 Hz AC-3
4 kW at 380...415 V AC 50/60 Hz AC-3
4 kW at 440 V AC 50/60 Hz AC-3
4 kW at 480 V AC 50/60 Hz AC-3
4 kW at 500...600 V AC 50/60 Hz AC-3
4 kW at 660...690 V AC 50/60 Hz AC-3
2.2 kW at 400 V AC 50/60 Hz AC-4
2.2 kW at 220...230 V AC 50/60 Hz AC-3e
4 kW at 380...415 V AC 50/60 Hz AC-3e
4 kW at 440 V AC 50/60 Hz AC-3e
4 kW at 480 V AC 50/60 Hz AC-3e
4 kW at 500...600 V AC 50/60 Hz AC-3e
4 kW at 660...690 V AC 50/60 Hz AC-3e
average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
Complementary
[ie] rated operational current 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit
9 A at <= 440 V AC AC-3 for power circuit
16 A (at <70 °C) at 690 V AC AC-1 for power circuit
9 A at <= 440 V AC AC-3e for power circuit
[ics] rated service breaking capacity 110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
110 A at 220...230 V conforming to IEC 60947
110 A at 380...400 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
[ith] conventional thermal current 20 A (at 50 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Product certifications CB Scheme
CCC
UL
CSA
EAC
CE
UKCA
Product or component type Contactor
Auxiliary contact composition 1 NO
minimum switching current 5 mA for signalling circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Auxiliary contacts type type instantaneous 1 NO
Device application Control
Control circuit voltage limits Operational: 0.85...1.1 Uc (at <50 °C)
Drop-out: 0.2...0.75 Uc (at <50 °C)
mechanical robustness Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Flame retardance V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Heat dissipation 1.3 W
Net weight 0.18 kg
Hold-in power consumption in va 4.5 VA (at 20 °C)
Inrush power in va 30 VA (at 20 °C)
Irms rated making capacity 110 A AC for power circuit conforming to NF C 63-110
110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Maximum operating rate 3600 cyc/h
operating time 10...20 ms coil de-energisation and NO opening
10...20 ms coil energisation and NO closing
minimum switching voltage 17 V for signalling circuit
Power pole contact composition 3 NO
Non overlap distance 0.5 mm
Poles description 3P
Utilisation category AC-1
AC-4
AC-3
AC-3e
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Signalling circuit frequency <= 400 Hz
Environment
Ambient air temp for storage/transportation -50…80 °C
operating altitude 2000 m without derating
overvoltage category III
standards EN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
protective treatment TC conforming to IEC 60068
TC conforming to DIN 50016
insulation resistance > 10 MOhm for signalling circuit
Recently viewed
26,87 € excl. VAT
32,78 € incl. VAT
Expected in 2-4 weeks