Main
Contactor application
Resistive load
Device short name
LC1F
Range
TeSys
[uc] control circuit voltage
230 V AC 40...400 Hz
[ui] rated insulation voltage
1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
control circuit type
AC at 40...400 Hz
average impedance
0.12 mOhm - Ith 1000 A 50 Hz
Complementary
[ie] rated operational current
1000 A (at <40 °C) at <= 440 V AC AC-1
[ue] rated operational voltage
<= 1000 V AC 50/60 Hz
<= 460 V DC
compatibility code
LC1F
[ics] rated service breaking capacity
5040 A conforming to IEC 60947-4-1
[icw] rated short-time withstand current
5050 A 40 °C - 10 s
4400 A 40 °C - 30 s
3400 A 40 °C - 1 min
2200 A 40 °C - 3 min
1600 A 40 °C - 10 min
[ith] conventional thermal current
1000 A (at 40 °C)
1250 A
Product certifications
CCC
ABS
UL
LROS (Lloyds register of shipping)
DNV
CB
RMRoS
RINA
BV
UKCA
Handle front plate colour
304 mm
Product or component type
Contactor
tightening torque
Control circuit: 1.2 N.m
Power circuit: 58 N.m
[uimp] rated impulse withstand voltage
8 kV
Connections - terminals
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: bar 2 cable(s) - busbar cross section: 60 x 5 mm
Power circuit: bolted connection
Associated fuse rating
1000 A gG at <= 440 V
630 A aM at <= 440 V
Control circuit voltage limits
Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C)
Drop-out: 0.25...0.5 Uc 40...400 Hz (at 55 °C)
width (w)
389 mm
Heat dissipation
20 W
Net weight
21.5 kg
Hold-in power consumption in va
22 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
Mounting support
Plate
power dissipation per pole
120 W AC-1
depth
255 mm
Inrush power in va
1650 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
mechanical durability
5 Mcycles
Maximum operating rate
1200 cyc/h 55 °C
operating time
40...80 ms closing
100...200 ms opening
Power pole contact composition
4 NO
Poles description
4P
Utilisation category
AC-1
Environment
Ambient air temp for storage/transportation
-60…80 °C
ip degree of protection
IP20 front face with shrouds conforming to IEC 60529
IP20 front face with shrouds conforming to VDE 0106
operating altitude
3000 m without derating
Permissible ambient air temperature around the device
-40…70 °C
Range of product
TeSys F
ambient air temperature for operation
-5…55 °C
overvoltage category
III
standards
EN 60947-1
IEC 60947-1
JIS C8201-4-1
IEC 60947-4-1
EN 60947-4-1
protective treatment
TH