All categories
Compare Cart

LC1F400 - contactor, TeSys F, 3P(3NO), AC-3, <=440V 1100A with coil LX1/LX9 48…1000V AC 40/400Hz, LX4 48...440V DC, LXE 100...250V AC 50/60Hz or 100…380V DC - Schneider Electric

Expected in 2-4 weeks
LC1F400 - contactor, TeSys F, 3P(3NO), AC-3, <=440V 1100A with coil LX1/LX9 48…1000V AC 40/400Hz, LX4 48...440V DC, LXE 100...250V AC 50/60Hz or 100…380V DC - Schneider Electric - contactor, TeSys F, 3P(3NO), AC-3, <=440V 1100A with coil LX1/LX9 48…1000V AC 40/400Hz, LX4 48...440V DC, LXE 100...250V AC 50/60Hz or 100…380V DC - Schneider Electric - 0
LC1F400 - contactor, TeSys F, 3P(3NO), AC-3, <=440V 1100A with coil LX1/LX9 48…1000V AC 40/400Hz, LX4 48...440V DC, LXE 100...250V AC 50/60Hz or 100…380V DC - Schneider Electric
720,01 € excl. VAT
878,41 € incl. VAT
Text About:
contactor, TeSys F, 3P(3NO), AC-3, <=440V 1100A with coil LX1/LX9 48…1000V AC 40/400Hz, LX4 48...440V DC, LXE 100...250V AC 50/60Hz or 100…380V DC - Schneider Electric
878,41 €
SPECIFICATIONS
Main
Contactor application Resistive load
Motor control
Device short name LC1F
Range TeSys
[uc] control circuit voltage 48...1000 V AC 40...400 Hz with LX1/LX9 coil
48...440 V DC with LX4 coil
100...250 V AC 50/60 Hz with LXE coil
100...380 V DC with LXE coil
Product Name TeSys F
[ui] rated insulation voltage 1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
motor power kW 185 kW at 1000 V AC 50/60 Hz (AC-3)
200 kW at 380...400 V AC 50/60 Hz (AC-3)
220 kW at 415 V AC 50/60 Hz (AC-3)
250 kW at 440 V AC 50/60 Hz (AC-3)
257 kW at 500 V AC 50/60 Hz (AC-3)
110 kW at 220...240 V AC 50/60 Hz (AC-3)
280 kW at 660...690 V AC 50/60 Hz (AC-3)
75 kW at 400 V AC 50/60 Hz (AC-4)
average impedance 0.26 mOhm - Ith 500 A 50 Hz
Complementary
[ie] rated operational current 500 A (at <40 °C) at <= 440 V AC AC-1
400 A (at <55 °C) at <= 440 V AC AC-3
[ue] rated operational voltage <= 1000 V AC 50/60 Hz
<= 460 V DC
compatibility code LC1F
[ics] rated service breaking capacity 3200 A conforming to IEC 60947-4-1
[icw] rated short-time withstand current 3600 A 40 °C - 10 s
2400 A 40 °C - 30 s
1700 A 40 °C - 1 min
1200 A 40 °C - 3 min
1000 A 40 °C - 10 min
[ith] conventional thermal current 500 A (at 40 °C)
Product certifications CB
ABS
DNV
RMRoS
LROS (Lloyds register of shipping)
BV
RINA
UL
CSA
UKCA
Handle front plate colour 206 mm
Product or component type Contactor
tightening torque Power circuit: 35 N.m
Control circuit: 1.2 N.m
Control circuit: 0.6 N.m
[uimp] rated impulse withstand voltage 8 kV
Connections - terminals Power circuit: bar 2 cable(s) - busbar cross section: 30 x 5 mm
Power circuit: lugs-ring terminals 2 cable(s) 150 mm²
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²flexible without cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.25…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²solid without cable end
Associated fuse rating 400 A aM at <= 440 V
500 A gG at <= 440 V
Control circuit voltage limits Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil
Drop-out: 0.3...0.5 Uc AC 40...400 Hz with LX1/LX9 coil
Operational: 0.85...1.1 Uc DC with LX4 coil
Drop-out: 0.2...0.35 Uc DC with LX4 coil
Operational: 85...275 V AC 50/60 Hz with LXE coil
Drop-out: 0...60 V AC 50/60 Hz with LXE coil
Operational: 85...418 V DC with LXE coil
Drop-out: 0...45 V DC with LXE coil
width (w) 213 mm
mechanical robustness Vibrations contactor open: 1.5 Gn, 5...300 Hz
Vibrations contactor closed: 5 Gn, 5...300 Hz
Shocks contactor open: 6 Gn for 1/2 sine wave (11 ms)
Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)
Heat dissipation 14 W
2.2…5.5 W
Net weight 8 kg
Hold-in power consumption in va 12…18 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
4…7.5 VA (at 20 °C)with LX4 coil
4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
2.5…4.0 VA (at 20 °C)with LXE coil
Mounting support Plate
power dissipation per pole 65 W AC-1
42 W AC-3
depth 219 mm
Inrush power in va 1000…1150 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
920…1140 VA (at 20 °C)with LX4 coil
360…470 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
410…450 VA (at 20 °C)with LXE coil
mechanical durability 10 Mcycles
Irms rated making capacity 4000 A AC conforming to IEC 60947-4-1
Maximum operating rate 2400 cyc/h 55 °C
operating time 40...75 ms closing for with LX1/LX9 coil
100...170 ms opening for with LX1/LX9 coil
50...60 ms closing for with LX4 coil
45...60 ms opening for with LX4 coil
40...80 ms closing for with LXE coil
6...54 ms opening for with LXE coil
Power pole contact composition 3 NO
Poles description 3P
Utilisation category AC-3
AC-1
AC-4
Environment
Ambient air temp for storage/transportation -60…80 °C
ip degree of protection IP20 front face with shrouds conforming to IEC 60529
IP20 front face with shrouds conforming to VDE 0106
operating altitude 3000 m without derating
Permissible ambient air temperature around the device -40…70 °C
ambient air temperature for operation -5…55 °C
overvoltage category III
standards JIS C8201-4-1
IEC 60947-4-1
IEC 60947-1
EN 60947-4-1
EN 60947-1
protective treatment TH
Recently viewed
720,01 € excl. VAT
878,41 € incl. VAT
Expected in 2-4 weeks