All categories
Compare Cart

LC1F3304P7 - TeSys F contactor 4P (4 NO) AC1 <= 440 V 400 A coil 230 V AC - Schneider Electric

Expected in 2-4 weeks
LC1F3304P7 - TeSys F contactor 4P (4 NO) AC1 <= 440 V 400 A coil 230 V AC - Schneider Electric - TeSys F contactor 4P (4 NO) AC1 <= 440 V 400 A coil 230 V AC - Schneider Electric - 0
LC1F3304P7 - TeSys F contactor 4P (4 NO) AC1 <= 440 V 400 A coil 230 V AC - Schneider Electric
1 437,46 € excl. VAT
1 753,70 € incl. VAT
Text About:
TeSys F contactor 4P (4 NO) AC1 <= 440 V 400 A coil 230 V AC - Schneider Electric
1 753,70 €
SPECIFICATIONS
Main
Contactor application Resistive load
Device short name LC1F
Range TeSys
[uc] control circuit voltage 230 V AC 40...400 Hz
[ui] rated insulation voltage 1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
control circuit type AC at 40...400 Hz
average impedance 0.28 mOhm - Ith 400 A 50 Hz
Complementary
[ie] rated operational current 400 A (at <40 °C) at <= 440 V AC AC-1
[ue] rated operational voltage <= 1000 V AC 50/60 Hz
<= 460 V DC
compatibility code LC1F
[ics] rated service breaking capacity 2640 A conforming to IEC 60947-4-1
[icw] rated short-time withstand current 2650 A 40 °C - 10 s
1800 A 40 °C - 30 s
1300 A 40 °C - 1 min
900 A 40 °C - 3 min
750 A 40 °C - 10 min
[ith] conventional thermal current 400 A (at 40 °C)
Product certifications ABS
CCC
BV
RINA
UL
CB
RMRoS
DNV
LROS (Lloyds register of shipping)
UKCA
Handle front plate colour 206 mm
Product or component type Contactor
tightening torque Control circuit: 1.2 N.m
Power circuit: 35 N.m
[uimp] rated impulse withstand voltage 8 kV
Connections - terminals Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: lugs-ring terminals 1 cable(s) 240 mm²
Power circuit: bar 2 cable(s) - busbar cross section: 30 x 5 mm
Power circuit: bolted connection
Associated fuse rating 400 A aM at <= 440 V
500 A gG at <= 440 V
Control circuit voltage limits Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C)
Drop-out: 0.35...0.55 Uc 40...400 Hz (at 55 °C)
width (w) 261 mm
Heat dissipation 8 W
Net weight 9.5 kg
Hold-in power consumption in va 10 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
Mounting support Plate
power dissipation per pole 44 W AC-1
depth 219 mm
Inrush power in va 650 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
mechanical durability 10 Mcycles
Maximum operating rate 2400 cyc/h 55 °C
operating time 40...65 ms closing
100...170 ms opening
Power pole contact composition 4 NO
Poles description 4P
Utilisation category AC-1
Environment
Ambient air temp for storage/transportation -60…80 °C
ip degree of protection IP20 front face with shrouds conforming to IEC 60529
IP20 front face with shrouds conforming to VDE 0106
operating altitude 3000 m without derating
Permissible ambient air temperature around the device -40…70 °C
Range of product TeSys F
ambient air temperature for operation -5…55 °C
overvoltage category III
standards IEC 60947-1
EN 60947-4-1
JIS C8201-4-1
EN 60947-1
IEC 60947-4-1
protective treatment TH
Recently viewed
1 437,46 € excl. VAT
1 753,70 € incl. VAT
Expected in 2-4 weeks