All categories
Compare Cart

LC1F225M5 - TeSys F contactor 3P (3 NO) AC3 <= 440 V 225 A coil 220 V AC - Schneider Electric

Expected in 2-4 weeks
LC1F225M5 - TeSys F contactor 3P (3 NO) AC3 <= 440 V 225 A coil 220 V AC - Schneider Electric - TeSys F contactor 3P (3 NO) AC3 <= 440 V 225 A coil 220 V AC - Schneider Electric - 0
LC1F225M5 - TeSys F contactor 3P (3 NO) AC3 <= 440 V 225 A coil 220 V AC - Schneider Electric
803,03 €
803,03 € incl. VAT
Text About:
TeSys F contactor 3P (3 NO) AC3 <= 440 V 225 A coil 220 V AC - Schneider Electric
803,03 €
SPECIFICATIONS
Main
Contactor application Resistive load
Motor control
Device short name LC1F
Range TeSys
[uc] control circuit voltage 220 V AC 50 Hz
[ui] rated insulation voltage 1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
control circuit type AC at 50 Hz
motor power kW 110 kW at 380...400 V AC 50/60 Hz (AC-3)
110 kW at 415 V AC 50/60 Hz (AC-3)
110 kW at 440 V AC 50/60 Hz (AC-3)
129 kW at 500 V AC 50/60 Hz (AC-3)
129 kW at 660...690 V AC 50/60 Hz (AC-3)
63 kW at 220...230 V AC 50/60 Hz (AC-3)
40 kW at 400 V AC 50/60 Hz (AC-4)
average impedance 0.32 mOhm - Ith 315 A 50 Hz
Complementary
[ie] rated operational current 315 A (at <40 °C) at <= 440 V AC-1
225 A (at <55 °C) at <= 440 V AC-3
[ue] rated operational voltage <= 460 V DC
<= 690 V AC 50/60 Hz
compatibility code LC1F
[ics] rated service breaking capacity 1800 A conforming to IEC 60947-4-1
[icw] rated short-time withstand current 1800 A 40 °C - 10 s
1000 A 40 °C - 30 s
850 A 40 °C - 1 min
560 A 40 °C - 3 min
440 A 40 °C - 10 min
[ith] conventional thermal current 315 A (at 40 °C)
Product certifications LROS (Lloyds register of shipping)
CB
BV
UL
DNV
RINA
RMRoS
CCC
ABS
Handle front plate colour 197 mm
Product or component type Contactor
tightening torque Control circuit: 1.2 N.m
Power circuit: 35 N.m
[uimp] rated impulse withstand voltage 8 kV
Connections - terminals Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: bar 2 cable(s) - busbar cross section: 32 x 4 mm
Power circuit: lugs-ring terminals 1 cable(s) 185 mm²
Power circuit: connector 1 cable(s) 185 mm²
Power circuit: bolted connection
Associated fuse rating 315 A gG at <= 440 V
250 A aM at <= 440 V
Control circuit voltage limits Operational: 0.85...1.1 Uc 50/60 Hz (at 55 °C)
Drop-out: 0.35...0.55 Uc 50/60 Hz (at 55 °C)
width (w) 168.5 mm
Heat dissipation 18…24 W
Net weight 4.75 kg
Hold-in power consumption in va 55 VA, 50 Hz cos phi 0.3 (at 20 °C)
Mounting support Plate
power dissipation per pole 32 W AC-1
16 W AC-3
depth 181 mm
Inrush power in va 805 VA, 50 Hz cos phi 0.3 (at 20 °C)
mechanical durability 10 Mcycles
Maximum operating rate 2400 cyc/h 55 °C
operating time 20...35 ms closing
7...15 ms opening
Power pole contact composition 3 NO
Poles description 3P
Utilisation category AC-4
AC-1
AC-3
Environment
Ambient air temp for storage/transportation -60…80 °C
ip degree of protection IP20 front face with shrouds conforming to IEC 60529
IP20 front face with shrouds conforming to VDE 0106
operating altitude 3000 m without derating
Permissible ambient air temperature around the device -40…70 °C
Range of product TeSys F
ambient air temperature for operation -5…55 °C
overvoltage category III
standards IEC 60947-1
JIS C8201-4-1
EN 60947-1
EN 60947-4-1
IEC 60947-4-1
protective treatment TH
Recently viewed
803,03 €
803,03 € incl. VAT
Expected in 2-4 weeks