SPECIFICATIONS
Main
Contactor application Resistive load
Motor control
Device short name LC1F
Range TeSys
[uc] control circuit voltage 24 V DC
[ui] rated insulation voltage 1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
control circuit type DC standard
motor power kW 110 kW at 380...400 V AC 50/60 Hz (AC-3)
110 kW at 415 V AC 50/60 Hz (AC-3)
110 kW at 440 V AC 50/60 Hz (AC-3)
129 kW at 500 V AC 50/60 Hz (AC-3)
129 kW at 660...690 V AC 50/60 Hz (AC-3)
63 kW at 220...230 V AC 50/60 Hz (AC-3)
40 kW at 400 V AC 50/60 Hz (AC-4)
average impedance 0.32 mOhm - Ith 315 A 50 Hz
Complementary
[ie] rated operational current 315 A (at <40 °C) at <= 440 V AC-1
225 A (at <55 °C) at <= 440 V AC-3
[ue] rated operational voltage <= 460 V DC
<= 690 V AC 50/60 Hz
compatibility code LC1F
[ics] rated service breaking capacity 1800 A conforming to IEC 60947-4-1
[icw] rated short-time withstand current 1800 A 40 °C - 10 s
1000 A 40 °C - 30 s
850 A 40 °C - 1 min
560 A 40 °C - 3 min
440 A 40 °C - 10 min
[ith] conventional thermal current 315 A (at 40 °C)
Product certifications CB
DNV
BV
ABS
UL
CSA
RMRoS
RINA
LROS (Lloyds register of shipping)
UKCA
Handle front plate colour 197 mm
Product or component type Contactor
tightening torque Control circuit: 1.2 N.m
Power circuit: 35 N.m
[uimp] rated impulse withstand voltage 8 kV
Connections - terminals Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: bar 2 cable(s) - busbar cross section: 32 x 4 mm
Power circuit: lugs-ring terminals 1 cable(s) 185 mm²
Power circuit: connector 1 cable(s) 185 mm²
Power circuit: bolted connection
Associated fuse rating 315 A gG at <= 440 V
250 A aM at <= 440 V
Control circuit voltage limits Operational: 0.85...1.1 Uc (at 55 °C)
Drop-out: 0.15...0.2 Uc (at 55 °C)
width (w) 168.5 mm
Heat dissipation 5 W
Net weight 4.75 kg
Hold-in power consumption in w 5 W at 20 °C
Mounting support Plate
power dissipation per pole 32 W AC-1
16 W AC-3
depth 181 mm
inrush power in w 800 W (at 20 °C)
mechanical durability 10 Mcycles
Maximum operating rate 2400 cyc/h 55 °C
operating time 30...40 ms closing
30...50 ms opening
contactor coil voltage 24 V DC standard
Motor power range 55…100 kW at 200…240 V 3 phases
110…220 kW at 480…500 V 3 phases
110…220 kW at 380…440 V 3 phases
Power pole contact composition 3 NO
motor starter type Direct on-line contactor
Poles description 3P
Utilisation category AC-1
AC-4
AC-3
Environment
Ambient air temp for storage/transportation -60…80 °C
ip degree of protection IP20 front face with shrouds conforming to IEC 60529
IP20 front face with shrouds conforming to VDE 0106
operating altitude 3000 m without derating
Permissible ambient air temperature around the device -40…70 °C
Range of product TeSys F
ambient air temperature for operation -5…55 °C
overvoltage category III
standards IEC 60947-4-1
EN 60947-4-1
JIS C8201-4-1
EN 60947-1
IEC 60947-1
protective treatment TH