All categories
Compare Cart

LC1F185 - contactor, TeSys F, 3P(3NO), AC-3, <=440V 185A with coil LX9, 24...600V AC 40/400Hz, LX4, 24...460V DC, LXE, 100...250V AC 50/60Hz or 100…380V DC - Schneider Electric

Expected in 2-4 weeks
LC1F185 - contactor, TeSys F, 3P(3NO), AC-3, <=440V 185A with coil LX9, 24...600V AC 40/400Hz, LX4, 24...460V DC, LXE, 100...250V AC 50/60Hz or 100…380V DC - Schneider Electric - contactor, TeSys F, 3P(3NO), AC-3, <=440V 185A with coil LX9, 24...600V AC 40/400Hz, LX4, 24...460V DC, LXE, 100...250V AC 50/60Hz or 100…380V DC - Schneider Electric - 0
LC1F185 - contactor, TeSys F, 3P(3NO), AC-3, <=440V 185A with coil LX9, 24...600V AC 40/400Hz, LX4, 24...460V DC, LXE, 100...250V AC 50/60Hz or 100…380V DC - Schneider Electric
409,05 € excl. VAT
499,04 € incl. VAT
Text About:
contactor, TeSys F, 3P(3NO), AC-3, <=440V 185A with coil LX9, 24...600V AC 40/400Hz, LX4, 24...460V DC, LXE, 100...250V AC 50/60Hz or 100…380V DC - Schneider Electric
499,04 €
SPECIFICATIONS
Main
Contactor application Resistive load
Motor control
Device short name LC1F
Range TeSys
[uc] control circuit voltage 24...575 V AC 40...400 Hz with LX9 coil
24...460 V DC with LX4 coil
100...250 V AC 50/60 Hz with LXE coil
100...380 V DC with LXE coil
Product Name TeSys F
[ui] rated insulation voltage 1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
motor power kW 100 kW at 415 V AC 50/60 Hz (AC-3)
100 kW at 440 V AC 50/60 Hz (AC-3)
110 kW at 500 V AC 50/60 Hz (AC-3)
90 kW at 380...400 V AC 50/60 Hz (AC-3)
55 kW at 220...240 V AC 50/60 Hz (AC-3)
110 kW at 660...690 V AC 50/60 Hz (AC-3)
33 kW at 400 V AC 50/60 Hz (AC-4)
average impedance 0.33 mOhm - Ith 275 A 50 Hz
Complementary
[ie] rated operational current 275 A (at <40 °C) at <= 440 V AC-1
185 A (at <55 °C) at <= 440 V AC-3
[ue] rated operational voltage <= 690 V AC 50/60 Hz
<= 460 V DC
compatibility code LC1F
[ics] rated service breaking capacity 1480 A conforming to IEC 60947-4-1
[icw] rated short-time withstand current 1500 A 40 °C - 10 s
920 A 40 °C - 30 s
740 A 40 °C - 1 min
500 A 40 °C - 3 min
400 A 40 °C - 10 min
[ith] conventional thermal current 275 A (at 40 °C)
Product certifications ABS
LROS (Lloyds register of shipping)
RINA
CSA
CB
UL
BV
RMRoS
DNV
UKCA
Handle front plate colour 174 mm
Product or component type Contactor
tightening torque Power circuit: 18 N.m
Control circuit: 1.2 N.m
Control circuit: 0.6 N.m
[uimp] rated impulse withstand voltage 8 kV
Connections - terminals Power circuit: bar 2 cable(s) - busbar cross section: 25 x 3 mm
Power circuit: lugs-ring terminals 1 cable(s) 150 mm²
Power circuit: connector 1 cable(s) 150 mm²
Power circuit: bolted connection
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²flexible without cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.25…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²solid without cable end
Associated fuse rating 200 A aM at <= 440 V
315 A gG at <= 440 V
Control circuit voltage limits Operational: 0.85...1.1 Uc AC 40...400 Hz with LX9 coil
Drop-out: 0.2...0.55 Uc AC 40...400 Hz with LX9 coil
Operational: 0.85...1.1 Uc DC with LX4 coil
Drop-out: 0.15...0.2 Uc DC with LX4 coil
Operational: 85...275 V AC 50/60 Hz with LXE coil
Drop-out: 0...60 V AC 50/60 Hz with LXE coil
Operational: 85...418 V DC with LXE coil
Drop-out: 0...45 V DC with LXE coil
width (w) 168.5 mm
mechanical robustness Vibrations contactor open: 2 Gn, 5...300 Hz
Vibrations contactor closed: 5 Gn, 5...300 Hz
Shocks contactor open: 7 Gn for 1/2 sine wave (11 ms)
Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)
Colour -
Heat dissipation 8…9.8 W
2.2…2.5 W
Net weight 5.45 kg
Hold-in power consumption in va 8.9…10.9 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil
4.13…5.07 VA (at 20 °C)with LX4 coil
4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
2.5…4.0 VA (at 20 °C)with LXE coil
Mounting support Plate
power dissipation per pole 25 W AC-1
12 W AC-3
depth 181 mm
Inrush power in va 950…1180 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil
737…902 VA (at 20 °C)with LX4 coil
280…310 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
270…320 VA (at 20 °C)with LXE coil
mechanical durability 10 Mcycles
Irms rated making capacity 1850 A conforming to IEC 60947-4-1
operating time 35 ms closing for with LX9 coil
130 ms opening for with LX9 coil
30...40 ms closing for with LX4 coil
30...50 ms opening for with LX4 coil
40...80 ms closing for with LXE coil
6...54 ms opening for with LXE coil
Power pole contact composition 3 NO
Poles description 3P
Utilisation category AC-3
AC-4
AC-1
Environment
Ambient air temp for storage/transportation -60…80 °C
ip degree of protection IP2X front face with shrouds conforming to IEC 60529
IP2X front face with shrouds conforming to VDE 0106
Permissible ambient air temperature around the device -40…70 °C
ambient air temperature for operation -5…55 °C
overvoltage category III
standards IEC 60947-4-1
EN 60947-1
JIS C8201-4-1
EN 60947-4-1
IEC 60947-1
protective treatment TH
Recently viewed
409,05 € excl. VAT
499,04 € incl. VAT
Expected in 2-4 weeks