All categories
Compare Cart

LC1F150F7 - TeSys F contactor 3P (3 NO) AC3 <= 440 V 150 A coil 115 V AC - Schneider Electric

Expected in 2-4 weeks
LC1F150F7 - TeSys F contactor 3P (3 NO) AC3 <= 440 V 150 A coil 115 V AC - Schneider Electric - TeSys F contactor 3P (3 NO) AC3 <= 440 V 150 A coil 115 V AC - Schneider Electric - 0
LC1F150F7 - TeSys F contactor 3P (3 NO) AC3 <= 440 V 150 A coil 115 V AC - Schneider Electric
426,42 € excl. VAT
520,23 € incl. VAT
Text About:
TeSys F contactor 3P (3 NO) AC3 <= 440 V 150 A coil 115 V AC - Schneider Electric
520,23 €
SPECIFICATIONS
Main
Contactor application Motor control
Resistive load
Device short name LC1F
Range TeSys
[uc] control circuit voltage 110 V AC 40...400 Hz
[ui] rated insulation voltage 1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
control circuit type AC at 40...400 Hz
motor power kW 75 kW at 380...400 V AC 50/60 Hz (AC-3)
80 kW at 415 V AC 50/60 Hz (AC-3)
80 kW at 440 V AC 50/60 Hz (AC-3)
90 kW at 500 V AC 50/60 Hz (AC-3)
100 kW at 660...690 V AC 50/60 Hz (AC-3)
40 kW at 220...230 V AC 50/60 Hz (AC-3)
22 kW at 400 V AC 50/60 Hz (AC-4)
average impedance 0.35 mOhm - Ith 250 A 50 Hz
Complementary
[ie] rated operational current 250 A (at <40 °C) at <= 440 V AC-1
150 A (at <55 °C) at <= 440 V AC-3
[ue] rated operational voltage <= 690 V AC 50/60 Hz
<= 460 V DC
compatibility code LC1F
[ics] rated service breaking capacity 1200 A conforming to IEC 60947-4-1
[icw] rated short-time withstand current 1200 A 40 °C - 10 s
700 A 40 °C - 30 s
600 A 40 °C - 1 min
450 A 40 °C - 3 min
350 A 40 °C - 10 min
[ith] conventional thermal current 250 A (at 40 °C)
Product certifications LROS (Lloyds register of shipping)
ABS
BV
CCC
CB
RMRoS
DNV
UL
RINA
UKCA
Handle front plate colour 170 mm
Product or component type Contactor
tightening torque Control circuit: 1.2 N.m
Power circuit: 18 N.m
[uimp] rated impulse withstand voltage 8 kV
Connections - terminals Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: bar 2 cable(s) - busbar cross section: 25 x 3 mm
Power circuit: lugs-ring terminals 1 cable(s) 120 mm²
Power circuit: connector 1 cable(s) 120 mm²
Power circuit: bolted connection
Associated fuse rating 160 A aM at <= 440 V
250 A gG at <= 440 V
Control circuit voltage limits Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C)
Drop-out: 0.2...0.55 Uc 40...400 Hz (at 55 °C)
width (w) 163.5 mm
Heat dissipation 5.9…7.2 W
Net weight 3.43 kg
Hold-in power consumption in va 8.1 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
Mounting support Plate
power dissipation per pole 22 W AC-1
8 W AC-3
depth 171 mm
Inrush power in va 770 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
mechanical durability 10 Mcycles
Maximum operating rate 2400 cyc/h 55 °C
operating time 35 ms closing (at Uc)
130 ms opening (at Uc)
Power pole contact composition 3 NO
Poles description 3P
Utilisation category AC-4
AC-1
AC-3
Environment
Ambient air temp for storage/transportation -60…80 °C
ip degree of protection IP2X front face with shrouds conforming to IEC 60529
IP2X front face with shrouds conforming to VDE 0106
operating altitude 3000 m without derating
Permissible ambient air temperature around the device 60…70 °C at Uc
Range of product TeSys F
ambient air temperature for operation -40…60 °C
overvoltage category III
standards IEC 60947-4-1
EN 60947-1
JIS C8201-4-1
IEC 60947-1
EN 60947-4-1
protective treatment TH