Contactor application
Resistive load
Motor control
Device short name
LC1F
Range
TeSys
[uc] control circuit voltage
440 V AC 40...400 Hz
[ui] rated insulation voltage
1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
control circuit type
AC at 40...400 Hz
motor power kW
55 kW at 380...400 V AC 50/60 Hz (AC-3)
59 kW at 415 V AC 50/60 Hz (AC-3)
59 kW at 440 V AC 50/60 Hz (AC-3)
75 kW at 500 V AC 50/60 Hz (AC-3)
80 kW at 660...690 V AC 50/60 Hz (AC-3)
30 kW at 220...230 V AC 50/60 Hz (AC-3)
18.5 kW at 400 V AC 50/60 Hz (AC-4)
average impedance
0.37 mOhm - Ith 200 A 50 Hz
Complementary
[ie] rated operational current
200 A (at <40 °C) at <= 440 V AC-1
115 A (at <55 °C) at <= 440 V AC-3
[ue] rated operational voltage
<= 690 V AC 50/60 Hz
<= 460 V DC
compatibility code
LC1F
[ics] rated service breaking capacity
920 A conforming to IEC 60947-4-1
[icw] rated short-time withstand current
1100 A 40 °C - 10 s
640 A 40 °C - 30 s
520 A 40 °C - 1 min
400 A 40 °C - 3 min
320 A 40 °C - 10 min
[ith] conventional thermal current
200 A (at 40 °C)
Product certifications
RINA
BV
ABS
RMRoS
CCC
UL
CB
DNV
LROS (Lloyds register of shipping)
UKCA
Handle front plate colour
162 mm
Product or component type
Contactor
tightening torque
Power circuit: 10 N.m
Control circuit: 1.2 N.m
[uimp] rated impulse withstand voltage
8 kV
Connections - terminals
Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm
Power circuit: lugs-ring terminals 1 cable(s) 95 mm²
Power circuit: connector 1 cable(s) 95 mm²
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: bolted connection
Associated fuse rating
125 A aM at <= 440 V
200 A gG at <= 440 V
Control circuit voltage limits
Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C)
Drop-out: 0.2...0.55 Uc 40...400 Hz (at 55 °C)
width (w)
163.3 mm
Heat dissipation
5.9…7.2 W
Net weight
3.43 kg
Hold-in power consumption in va
8.1 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
Mounting support
Plate
power dissipation per pole
15 W AC-1
5 W AC-3
depth
171 mm
Inrush power in va
770 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
mechanical durability
10 Mcycles
Maximum operating rate
2400 cyc/h 55 °C
operating time
35 ms closing (at Uc)
130 ms opening (at Uc)
Power pole contact composition
3 NO
Poles description
3P
Utilisation category
AC-4
AC-1
AC-3
Environment
Ambient air temp for storage/transportation
-60…80 °C
ip degree of protection
IP2X front face with shrouds conforming to IEC 60529
IP2X front face with shrouds conforming to VDE 0106
operating altitude
3000 m without derating
Permissible ambient air temperature around the device
60…70 °C at Uc
Range of product
TeSys F
ambient air temperature for operation
-40…60 °C
overvoltage category
III
standards
EN 60947-1
IEC 60947-1
EN 60947-4-1
IEC 60947-4-1
JIS C8201-4-1
protective treatment
TH