All categories
Compare Cart

LC1DT80AFD - TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 80 A 110 V DC standard coil - Schneider Electric

Pending restock
LC1DT80AFD - TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 80 A 110 V DC standard coil - Schneider Electric - TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 80 A 110 V DC standard coil - Schneider Electric - 0
LC1DT80AFD - TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 80 A 110 V DC standard coil - Schneider Electric
331,61 € excl. VAT
411,19 € incl. VAT
Text About:
TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 80 A 110 V DC standard coil - Schneider Electric
411,19 €
SPECIFICATIONS
Main
Contactor application Resistive load
Device short name LC1D
Range TeSys
TeSys Deca
[uc] control circuit voltage 110 V DC
[ui] rated insulation voltage Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
control circuit type DC standard
average impedance 1.6 mOhm - Ith 80 A 50 Hz for power circuit
Complementary
[ie] rated operational current 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
Power circuit: <= 300 V DC
compatibility code LC1D
[ics] rated service breaking capacity 1000 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current 520 A 40 °C - 10 s for power circuit
900 A 40 °C - 1 s for power circuit
110 A 40 °C - 10 min for power circuit
260 A 40 °C - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
[ith] conventional thermal current 10 A (at 60 °C) for signalling circuit
80 A (at 60 °C) for power circuit
Product certifications RINA
UL
BV
CSA
GOST
LROS (Lloyds register of shipping)
GL
CCC
DNV
Handle front plate colour 122 mm
Product or component type Contactor
tightening torque Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 8 N.m - on screw clamp terminals - cable 25…35 mm² hexagonal screw head 4 mm
Power circuit: 5 N.m - on screw clamp terminals - cable 1…25 mm² hexagonal screw head 4 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Auxiliary contact composition 1 NO + 1 NC
Connections - terminals Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
Power circuit: screw connection 1 1…35 mm² - cable stiffness: flexible without cable end
Power circuit: screw connection 2 1…25 mm² - cable stiffness: flexible without cable end
Power circuit: screw connection 1 1…35 mm² - cable stiffness: flexible with cable end
Power circuit: screw connection 2 1…25 mm² - cable stiffness: flexible with cable end
Power circuit: screw connection 1 1…35 mm² - cable stiffness: solid without cable end
Power circuit: screw connection 2 1…25 mm² - cable stiffness: solid without cable end
minimum switching current 5 mA for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
125 A gG at <= 690 V coordination type 1 for power circuit
125 A gG at <= 690 V coordination type 2 for power circuit
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
contact compatibility M7
Control circuit voltage limits 0.1...0.3 Uc (-40…70 °C):drop-out DC
0.75...1.25 Uc (-40…60 °C):operational DC
1...1.25 Uc (60…70 °C):operational DC
width (w) 70 mm
mechanical robustness Vibrations contactor open (2 Gn, 5...300 Hz)
Vibrations contactor closed (4 Gn, 5...300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (10 Gn for 11 ms)
Flame retardance V1 conforming to UL 94
Net weight 1.225 kg
time constant 34 ms
Hold-in power consumption in w 7.4 W at 20 °C
Mounting support Plate
Rail
power dissipation per pole 10.2 W AC-1
depth 120 mm
inrush power in w 19 W (at 20 °C)
mechanical durability 10 Mcycles
electrical durability 0.5 Mcycles 80 A AC-1 at Ue <= 440 V
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
1000 A at 440 V for power circuit conforming to IEC 60947
Pollution degree 3
Maximum operating rate 3600 cyc/h 60 °C
operating time 42.5...57.5 ms closing
16...24 ms opening
minimum switching voltage 17 V for signalling circuit
non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Protective cover With
coil technology Built-in bidirectional peak limiting diode suppressor
Pole contact composition 4 NO
Poles description 4P
Utilisation category AC-1
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Signalling circuit frequency 25...400 Hz
Environment
Climatic withstand conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
ip degree of protection IP20 front face conforming to IEC 60529
operating altitude 0...3000 m
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Range of product TeSys Deca
overvoltage category III
standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1
fire resistance 850 °C conforming to IEC 60695-2-1
protective treatment TH conforming to IEC 60068-2-30
insulation resistance > 10 MOhm for signalling circuit
About this product

The LC1DT80AFD - TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 80 A 110 V DC standard coil is developed to respond to the needs of trade professionals, such as system integrators, electrical installers, upkeep firms, and primary equipment makers. LC1DT80AFD yields first-rate integrity and gain for technicians in the electromechanical industry. This TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 80 A 110 V DC standard coil and other TeSyS Deca Contactors from Schneider Electric are available at the most favorable cost and distribution time through BALTELEC.EU, a well-regarded retailer attending to specialists in their buying needs.

Technicians who have adopted Schneider Electric TeSyS Deca Contactors have persistently praised the producer's stability. It has been indicated that the exceptional competence of LC1DT80AFD - TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 80 A 110 V DC standard coil extends to a diverse range of use. Its elite characteristics make it appropriate to cater to varied requirements, securing success in your industrial, tertiary, and automation endeavors.

BALTELEC commits in addressing industrial and tertiary professionals’ needs. We get the particular demands and requirements of our consumers in the industry. By teaming up with our professionals, your business secure access to the superior rates and availability of the top-of-the-line products like LC1DT80AFD - TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 80 A 110 V DC standard coil from Schneider Electric at an attractive price. Registered users appreciate added discounts and top-tier service.

Start immediately and purchase LC1DT80AFD - TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 80 A 110 V DC standard coil at our protected and streamlined e-commerce site. Don't delay in making this intelligent selection that warrants the top quality and complies with the special prerequisites of users like your firm.

Should you experience any doubts or concerns about LC1DT80AFD - TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 80 A 110 V DC standard coil or any other Schneider Electric products, drop us a line or refer to our FAQs section below. We have amassed answers to usual doubts to advise you further in making an enlightened decision about industrial and tertiary electrical components.

Remember, LC1DT80AFD - TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 80 A 110 V DC standard coil from Schneider Electric is sure, budget-friendly, and excellent to its competitors in the TeSyS Deca Contactors category. Make it a part of your electrical system immediately. Shop with confidence at Baltelec e-shop, your trusted partner for all your Schneider Electric.

In our Baltelec.eu online store you will come across TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 80 A 110 V DC standard coil - LC1DT80AFD worth 404.56 €, which will be a secure and current solution for your needs. This item is produced by the Schneider Electric brand using the advanced technologies and complies with the maximum standards of protection and productivity. We furnish commodities from the TeSyS Deca Contactors category that mix resilience and usability, which is an excellent decision for various intents. Independent of whether you require machinery for small manufacturing or for qualified industrial application, TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 80 A 110 V DC standard coil will be a safe adjunct in your occupation.

Baltelec aims to make the shopping process as accessible and fast as realizable for our consumers. We offer detailed depictions and high-quality pictures of TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 80 A 110 V DC standard coil so that you can make an conscious choice. A team of virtuosos is always ready to help you with any issues in the TeSyS Deca Contactors section relevant to the choosing and use of merchandise. We are persuaded that TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 80 A 110 V DC standard coil will meet your demands and become an needed element of your gear for just 404.56 €.

Customer Queries about Schneider Electric TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 80 A 110 V DC standard coil:

Recently viewed
LC1DT80AFD - Schneider Electric
TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 80 A 110 V DC standard coil
331,61 € excl. VAT
411,19 € incl. VAT
Pending restock