SPECIFICATIONS
Main
Contactor application Resistive load
Device short name LC1D
Range TeSys
TeSys Deca
[uc] control circuit voltage 110 V AC 50/60 Hz
[ui] rated insulation voltage Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
control circuit type AC at 50/60 Hz
average impedance 2.5 mOhm - Ith 20 A 50 Hz for power circuit
Complementary
[ie] rated operational current 20 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
Power circuit: <= 300 V DC
compatibility code LC1D
[ics] rated service breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current 30 A 40 °C - 10 min for power circuit
61 A 40 °C - 1 min for power circuit
105 A 40 °C - 10 s for power circuit
210 A 40 °C - 1 s for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
[ith] conventional thermal current 10 A (at 60 °C) for signalling circuit
20 A (at 60 °C) for power circuit
Product certifications BV
GOST
LROS (Lloyds register of shipping)
DNV
UL
CSA
GL
RINA
CCC
Handle front plate colour 85 mm
Product or component type Contactor
tightening torque Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Auxiliary contact composition 1 NO + 1 NC
Connections - terminals Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
minimum switching current 5 mA for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
25 A gG at <= 690 V coordination type 1 for power circuit
20 A gG at <= 690 V coordination type 2 for power circuit
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
contact compatibility M6
Control circuit voltage limits 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
width (w) 45 mm
mechanical robustness Vibrations contactor open (2 Gn, 5...300 Hz)
Vibrations contactor closed (4 Gn, 5...300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (10 Gn for 11 ms)
Flame retardance V1 conforming to UL 94
Heat dissipation 2…3 W at 50/60 Hz
Net weight 0.365 kg
Hold-in power consumption in va 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C)
Mounting support Rail
Plate
power dissipation per pole 1.56 W AC-1
depth 92 mm
Inrush power in va 70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C)
mechanical durability 15 Mcycles
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
250 A at 440 V for power circuit conforming to IEC 60947
Pollution degree 3
Maximum operating rate 3600 cyc/h 60 °C
operating time 4...19 ms opening
12...22 ms closing
minimum switching voltage 17 V for signalling circuit
non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Protective cover With
coil technology Without built-in suppressor module
Pole contact composition 4 NO
Poles description 4P
Utilisation category AC-1
AC-3
AC-3e
AC-4
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Signalling circuit frequency 25...400 Hz
Environment
Climatic withstand conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
ip degree of protection IP20 front face conforming to IEC 60529
operating altitude 0...3000 m
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Range of product TeSys Deca
overvoltage category III
standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1
fire resistance 850 °C conforming to IEC 60695-2-1
protective treatment TH conforming to IEC 60068-2-30
insulation resistance > 10 MOhm for signalling circuit
About this product

The LC1DT20F7 - TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 20 A 110 V AC 50/60 Hz coil is devised to address the demands of business buyers, such as electrical contractors, circuit experts, repair companies, and Industry suppliers. LC1DT20F7 dispenses unmatched integrity and benefits for contractors in the electrotechnical industry. This TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 20 A 110 V AC 50/60 Hz coil and other TeSyS Deca Contactors from Schneider Electric are on offer at the lowest cost and turnaround time through BaltElec, a reliable distributor assisting contractors in their buying needs.

Professionals who have selected Schneider Electric TeSyS Deca Contactors have continuously approved the manufacturer’s stability. It has been indicated that the superlative efficiency of LC1DT20F7 - TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 20 A 110 V AC 50/60 Hz coil extends to a extensive scope of functions. Its excellent components make it ideal solution for wide-ranging specifications, ensuring your industrial, tertiary and automation projects success.

BALTELEC specializes in accommodating industrial and tertiary professionals’ needs. We recognize the distinct requirements and desires of our patrons in the realm. By teaming up with Baltelec team, our partners access access to the premier price and lead time of superior products like LC1DT20F7 - TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 20 A 110 V AC 50/60 Hz coil from Schneider Electric at an attractive price. Authorized buyers get additional savings and expedited requests handling.

Get started and grab LC1DT20F7 - TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 20 A 110 V AC 50/60 Hz coil at our trusted and hassle-free webshop. Don't delay in making this astute option that assures the superior quality and covers the distinct specifications of customers like you.

Should you experience any worries or concerns about LC1DT20F7 - TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 20 A 110 V AC 50/60 Hz coil or any other Schneider Electric products, contact us or refer to our Frequently Asked Questions section below. We have amassed answers to popular queries to aid you further in making an well-considered decision about industrial and tertiary electrical components.

Remember, LC1DT20F7 - TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 20 A 110 V AC 50/60 Hz coil from Schneider Electric is sure, value-priced, and high-quality to its counterparts in the TeSyS Deca Contactors category. Don't hesitate to make it a part of your apparatus without delay. Take advantage of at baltele.eu, your faithful dealer for all your professional electrical equipment and automation needs.

In our Baltelec.eu online store you will encounter TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 20 A 110 V AC 50/60 Hz coil - LC1DT20F7 worth 49.99 €, which will be a steadfast and cutting-edge solution for your requirements. This thing is fabricated by the Schneider Electric brand using the modern technologies and follows the maximum standards of safety and capability. We furnish products from the TeSyS Deca Contactors category that blend strength and efficacy, which is an outstanding preference for various operations. Irrespective of whether you necessitate apparatus for small production or for adept industrial purpose, TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 20 A 110 V AC 50/60 Hz coil will be a dependable partner in your endeavor.

Baltelec attempts to make the acquiring process as smooth and fast as possible for our consumers. We offer detailed summaries and high-quality pictures of TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 20 A 110 V AC 50/60 Hz coil so that you can make an educated choice. A team of maestros is always ready to help you with any inquiries in the TeSyS Deca Contactors section connected to the selection and use of items. We are positive that TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 20 A 110 V AC 50/60 Hz coil will meet your prospects and become an imperative element of your equipment for just 49.99 €.

What People Ask about LC1DT20F7:

Recently viewed
LC1DT20F7 - Schneider Electric
TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 20 A 110 V AC 50/60 Hz coil
40,98 € excl. VAT
50,81 € incl. VAT
Pending restock