All categories
Compare Cart

LC1D65008M7 - TeSys Deca contactor 4P(2 NO + 2 NC) AC1 <= 440 V 80 A 220 V AC 50/60 Hz coil - Schneider Electric

Expected in 2-4 weeks
LC1D65008M7 - TeSys Deca contactor 4P(2 NO + 2 NC) AC1 <= 440 V 80 A 220 V AC 50/60 Hz coil - Schneider Electric - TeSys Deca contactor 4P(2 NO + 2 NC) AC1 <= 440 V 80 A 220 V AC 50/60 Hz coil - Schneider Electric - 0
LC1D65008M7 - TeSys Deca contactor 4P(2 NO + 2 NC) AC1 <= 440 V 80 A 220 V AC 50/60 Hz coil - Schneider Electric
574,67 € excl. VAT
701,09 € incl. VAT
Text About:
TeSys Deca contactor 4P(2 NO + 2 NC) AC1 <= 440 V 80 A 220 V AC 50/60 Hz coil - Schneider Electric
701,09 €
SPECIFICATIONS
Main
Contactor application Resistive load
Device short name LC1D
Range TeSys
[uc] control circuit voltage 220 V AC 50/60 Hz
[ui] rated insulation voltage Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
control circuit type AC at 50/60 Hz
average impedance 1.5 mOhm - Ith 80 A 50 Hz for power circuit
Complementary
[ie] rated operational current 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
Power circuit: <= 300 V DC
compatibility code LC1D
[ics] rated service breaking capacity 1000 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current 520 A 40 °C - 10 s for power circuit
900 A 40 °C - 1 s for power circuit
110 A 40 °C - 10 min for power circuit
260 A 40 °C - 1 min for power circuit
[ith] conventional thermal current 80 A (at 60 °C) for power circuit
Product certifications RINA
BV
CSA
UL
LROS (Lloyds register of shipping)
CCC
DNV
GL
GOST
Handle front plate colour 127 mm
Product or component type Contactor
tightening torque Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 8 N.m - on screw clamp terminals - cable 25…35 mm² hexagonal screw head 4 mm
Power circuit: 5 N.m - on screw clamp terminals - cable 1…25 mm² hexagonal screw head 4 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Connections - terminals Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 1…35 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 1…25 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 1…35 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1…25 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 1…35 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 1…25 mm² - cable stiffness: solid without cable end
Associated fuse rating 125 A gG at <= 690 V coordination type 1 for power circuit
125 A gG at <= 690 V coordination type 2 for power circuit
contact compatibility M1
Control circuit voltage limits 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
width (w) 85 mm
mechanical robustness Shocks contactor open (8 Gn for 11 ms)
Shocks contactor closed (10 Gn for 11 ms)
Vibrations contactor opened (2 Gn, 5...300 Hz)
Vibrations contactor closed (3 Gn, 5...300 Hz)
Flame retardance V1 conforming to UL 94
Heat dissipation 4…5 W at 50/60 Hz
Net weight 1.45 kg
Hold-in power consumption in va 13 VA 60 Hz cos phi 0.3 (at 20 °C)
15 VA 50 Hz cos phi 0.3 (at 20 °C)
Mounting support Plate
Rail
power dissipation per pole 9.6 W AC-1
depth 125 mm
Inrush power in va 140 VA 60 Hz cos phi 0.75 (at 20 °C)
160 VA 50 Hz cos phi 0.75 (at 20 °C)
mechanical durability 6 Mcycles
electrical durability 1.4 Mcycles 80 A AC-1 at Ue <= 440 V
Irms rated making capacity 1000 A at 440 V for power circuit conforming to IEC 60947
Pollution degree 3
Maximum operating rate 3600 cyc/h 60 °C
operating time 4...19 ms opening
12...26 ms closing
Protective cover Without
coil technology Without built-in suppressor module
Pole contact composition 2 NO + 2 NC
Poles description 4P
Utilisation category AC-1
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Environment
Climatic withstand conforming to IACS E10 exposure to damp heat
ip degree of protection IP20 front face conforming to IEC 60529
operating altitude 0...3000 m
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Range of product TeSys Deca
overvoltage category III
standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
fire resistance 850 °C conforming to IEC 60695-2-1
protective treatment TH conforming to IEC 60068-2-30
Recently viewed
574,67 € excl. VAT
701,09 € incl. VAT
Expected in 2-4 weeks