SPECIFICATIONS
Main
Contactor application Resistive load
Motor control
Device short name LC1D
Range TeSys
TeSys Deca
[uc] control circuit voltage 380 V AC 50/60 Hz
[ui] rated insulation voltage Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
control circuit type AC at 50/60 Hz
motor power kW 18.5 kW at 380...400 V AC 50/60 Hz (AC-3)
11 kW at 220...230 V AC 50/60 Hz (AC-3)
22 kW at 415...440 V AC 50/60 Hz (AC-3)
22 kW at 500 V AC 50/60 Hz (AC-3)
30 kW at 660...690 V AC 50/60 Hz (AC-3)
9 kW at 400 V AC 50/60 Hz (AC-4)
18.5 kW at 380...400 V AC 50/60 Hz (AC-3e)
11 kW at 220...230 V AC 50/60 Hz (AC-3e)
22 kW at 415...440 V AC 50/60 Hz (AC-3e)
22 kW at 500 V AC 50/60 Hz (AC-3e)
30 kW at 660...690 V AC 50/60 Hz (AC-3e)
average impedance 1.5 mOhm - Ith 60 A 50 Hz for power circuit
Complementary
[ie] rated operational current 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
40 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
Power circuit: <= 300 V DC
compatibility code LC1D
[ics] rated service breaking capacity 800 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current 320 A 40 °C - 10 s for power circuit
720 A 40 °C - 1 s for power circuit
72 A 40 °C - 10 min for power circuit
165 A 40 °C - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
[ith] conventional thermal current 10 A (at 60 °C) for signalling circuit
60 A (at 60 °C) for power circuit
Product certifications CCC
GOST
UL
CSA
Handle front plate colour 122 mm
Product or component type Contactor
tightening torque Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mm
Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1…25 mm² hexagonal screw head 4 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Auxiliary contact composition 1 NO + 1 NC
Connections - terminals Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
Power circuit: EverLink BTR screw connectors 1 1…35 mm² - cable stiffness: flexible without cable end
Power circuit: EverLink BTR screw connectors 2 1…25 mm² - cable stiffness: flexible without cable end
Power circuit: EverLink BTR screw connectors 1 1…35 mm² - cable stiffness: flexible with cable end
Power circuit: EverLink BTR screw connectors 2 1…25 mm² - cable stiffness: flexible with cable end
Power circuit: EverLink BTR screw connectors 1 1…35 mm² - cable stiffness: solid without cable end
Power circuit: EverLink BTR screw connectors 2 1…25 mm² - cable stiffness: solid without cable end
minimum switching current 5 mA for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
80 A gG at <= 690 V coordination type 1 for power circuit
80 A gG at <= 690 V coordination type 2 for power circuit
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
contact compatibility M2
Control circuit voltage limits 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
width (w) 55 mm
mechanical robustness Vibrations contactor open (2 Gn, 5...300 Hz)
Vibrations contactor closed (4 Gn, 5...300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (10 Gn for 11 ms)
Flame retardance V1 conforming to UL 94
Heat dissipation 4…5 W at 50/60 Hz
Net weight 0.85 kg
Hold-in power consumption in va 13 VA 60 Hz cos phi 0.3 (at 20 °C)
15 VA 50 Hz cos phi 0.3 (at 20 °C)
Motor power hp 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
10 hp at 230/240 V AC 50/60 Hz for 3 phases motors
30 hp at 575/600 V AC 50/60 Hz for 3 phases motors
10 hp at 200/208 V AC 50/60 Hz for 3 phases motors
3 hp at 115 V AC 50/60 Hz for 1 phase motors
30 hp at 460/480 V AC 50/60 Hz for 3 phases motors
Mounting support Plate
Rail
power dissipation per pole 2.4 W AC-3
5.4 W AC-1
2.4 W AC-3e
depth 120 mm
Inrush power in va 140 VA 60 Hz cos phi 0.75 (at 20 °C)
160 VA 50 Hz cos phi 0.75 (at 20 °C)
mechanical durability 6 Mcycles
electrical durability 1.4 Mcycles 60 A AC-1 at Ue <= 440 V
1.5 Mcycles 40 A AC-3 at Ue <= 440 V
1.5 Mcycles 40 A AC-3e at Ue <= 440 V
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
800 A at 440 V for power circuit conforming to IEC 60947
Pollution degree 3
Maximum operating rate 3600 cyc/h 60 °C
operating time 4...19 ms opening
12...26 ms closing
minimum switching voltage 17 V for signalling circuit
non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Protective cover With
coil technology Without built-in suppressor module
Pole contact composition 3 NO
Poles description 3P
Utilisation category AC-4
AC-1
AC-3
AC-3e
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Signalling circuit frequency 25...400 Hz
Environment
Climatic withstand conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
ip degree of protection IP20 front face conforming to IEC 60529
operating altitude 0...3000 m
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Range of product TeSys Deca
overvoltage category III
standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1
fire resistance 850 °C conforming to IEC 60695-2-1
protective treatment TH conforming to IEC 60068-2-30
insulation resistance > 10 MOhm for signalling circuit
About this product

The LC1D40AQ7 - TeSys Deca contactor 3P(3 NO) AC3/AC3e <= 440 V 40 A 380 V AC 50/60 Hz coil is engineered to cover the obligations of specialized professionals, such as system integrators, electrical fitters, service organizations, and industry fabricators. LC1D40AQ7 furnishes superior reliability and beneficence for consultants in the power engineering industry. This TeSys Deca contactor 3P(3 NO) AC3/AC3e <= 440 V 40 A 380 V AC 50/60 Hz coil and other TeSyS Deca Contactors from Schneider Electric are procurable at the most economical price and delivery schedule through BALTELEC, a respected retailer assisting contractors in their supply needs.

Users who have procured Schneider Electric TeSyS Deca Contactors have regularly applauded the creator's solidity. It has been remarked that the superior effectiveness of LC1D40AQ7 - TeSys Deca contactor 3P(3 NO) AC3/AC3e <= 440 V 40 A 380 V AC 50/60 Hz coil extends to a wide range of utilizations. Its elite features make it proper pick to suit a variety of needs, ensuring the success of your industrial, tertiary, and automation projects.

BALTELEC centers in catering industrial and tertiary professionals’ needs. We comprehend the individual expectations and anticipations of our buyers in the realm. By working with BaltElec, your business gain access to the premier charges and inventory of the top-of-the-line products like LC1D40AQ7 - TeSys Deca contactor 3P(3 NO) AC3/AC3e <= 440 V 40 A 380 V AC 50/60 Hz coil from Schneider Electric at an economical price. Our registered accounts take pleasure in further discounts and exclusive assistance.

Don't wait and purchase LC1D40AQ7 - TeSys Deca contactor 3P(3 NO) AC3/AC3e <= 440 V 40 A 380 V AC 50/60 Hz coil at our well-established and streamlined website. Don't delay in making this savvy option that confirms the highest quality and meets the customized requests of professionals like you.

If there are any problems or concerns about LC1D40AQ7 - TeSys Deca contactor 3P(3 NO) AC3/AC3e <= 440 V 40 A 380 V AC 50/60 Hz coil or any other Schneider Electric products, connect with us or refer to our FAQ section section below. We have consolidated answers to usual issues to support you further in making an well-considered decision about industrial and tertiary electrical components.

Remember, LC1D40AQ7 - TeSys Deca contactor 3P(3 NO) AC3/AC3e <= 440 V 40 A 380 V AC 50/60 Hz coil from Schneider Electric is safe, economical, and premier to its competitors in the TeSyS Deca Contactors category. Make it a part of your electrical system without delay. Order at Baltelec webstore, your reliable retailer for all your TeSyS Deca Contactors.

In our Baltelec.eu web store you will find TeSys Deca contactor 3P(3 NO) AC3/AC3e <= 440 V 40 A 380 V AC 50/60 Hz coil - LC1D40AQ7 worth 118.87 €, which will be a reliable and state-of-the-art solution for your preferences. This goods is constructed by the Schneider Electric brand using the most recent technologies and adheres to the highest standards of assurance and effectiveness. We deliver things from the TeSyS Deca Contactors category that amalgamate endurance and utility, which is an superior possibility for various uses. In spite of whether you seek tools for small output or for adept industrial operation, TeSys Deca contactor 3P(3 NO) AC3/AC3e <= 440 V 40 A 380 V AC 50/60 Hz coil will be a dependable helper in your undertaking.

Baltelec labors to make the procuring process as accessible and fast as achievable for our users. We offer detailed accounts and high-quality shots of TeSys Deca contactor 3P(3 NO) AC3/AC3e <= 440 V 40 A 380 V AC 50/60 Hz coil so that you can make an aware choice. A team of professionals is always ready to help you with any doubts in the TeSyS Deca Contactors section associated to the nomination and use of products. We are persuaded that TeSys Deca contactor 3P(3 NO) AC3/AC3e <= 440 V 40 A 380 V AC 50/60 Hz coil will meet your standards and become an significant element of your setup for just 118.87 €.

What People Ask about LC1D40AQ7:

Recently viewed
LC1D40AQ7 - Schneider Electric
TeSys Deca contactor 3P(3 NO) AC3/AC3e <= 440 V 40 A 380 V AC 50/60 Hz coil
97,43 € excl. VAT
120,82 € incl. VAT
Pending restock