SPECIFICATIONS
Main
Contactor application Motor control
Resistive load
Device short name LC1D
Range TeSys
TeSys Deca
[uc] control circuit voltage 24 V DC
[ui] rated insulation voltage Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
control circuit type DC standard
motor power kW 18.5 kW at 380...400 V AC 50/60 Hz (AC-3)
11 kW at 220...230 V AC 50/60 Hz (AC-3)
22 kW at 415...440 V AC 50/60 Hz (AC-3)
22 kW at 500 V AC 50/60 Hz (AC-3)
30 kW at 660...690 V AC 50/60 Hz (AC-3)
9 kW at 400 V AC 50/60 Hz (AC-4)
18.5 kW at 380...400 V AC 50/60 Hz (AC-3e)
11 kW at 220...230 V AC 50/60 Hz (AC-3e)
22 kW at 415...440 V AC 50/60 Hz (AC-3e)
22 kW at 500 V AC 50/60 Hz (AC-3e)
30 kW at 660...690 V AC 50/60 Hz (AC-3e)
average impedance 1.5 mOhm - Ith 60 A 50 Hz for power circuit
Complementary
[ie] rated operational current 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
40 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
Power circuit: <= 300 V DC
compatibility code LC1D
[ics] rated service breaking capacity 800 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current 320 A 40 °C - 10 s for power circuit
720 A 40 °C - 1 s for power circuit
72 A 40 °C - 10 min for power circuit
165 A 40 °C - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
[ith] conventional thermal current 10 A (at 60 °C) for signalling circuit
60 A (at 60 °C) for power circuit
Product certifications UL
CSA
CCC
GOST
Handle front plate colour 122 mm
Product or component type Contactor
tightening torque Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mm
Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 0.75…25 mm² hexagonal screw head 4 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Auxiliary contact composition 1 NO + 1 NC
Connections - terminals Control circuit: spring terminals 1 0.75…2.5 mm² - cable stiffness: flexible without cable end
Control circuit: spring terminals 2 0.75…2.5 mm² - cable stiffness: flexible without cable end
Power circuit: EverLink BTR screw connectors 1 1…35 mm² - cable stiffness: flexible without cable end
Power circuit: EverLink BTR screw connectors 2 1…25 mm² - cable stiffness: flexible without cable end
Power circuit: EverLink BTR screw connectors 1 1…35 mm² - cable stiffness: flexible with cable end
Power circuit: EverLink BTR screw connectors 2 1…25 mm² - cable stiffness: flexible with cable end
Power circuit: EverLink BTR screw connectors 1 1…35 mm² - cable stiffness: solid without cable end
Power circuit: EverLink BTR screw connectors 2 1…25 mm² - cable stiffness: solid without cable end
minimum switching current 5 mA for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
80 A gG at <= 690 V coordination type 1 for power circuit
80 A gG at <= 690 V coordination type 2 for power circuit
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
contact compatibility M4
Control circuit voltage limits 0.1...0.3 Uc (-40…70 °C):drop-out DC
0.75...1.25 Uc (-40…60 °C):operational DC
1...1.25 Uc (60…70 °C):operational DC
width (w) 55 mm
mechanical robustness Vibrations contactor open (2 Gn, 5...300 Hz)
Vibrations contactor closed (4 Gn, 5...300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (10 Gn for 11 ms)
Flame retardance V1 conforming to UL 94
Net weight 0.925 kg
time constant 34 ms
Hold-in power consumption in w 7.4 W at 20 °C
Motor power hp 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
10 hp at 230/240 V AC 50/60 Hz for 3 phases motors
30 hp at 575/600 V AC 50/60 Hz for 3 phases motors
10 hp at 200/208 V AC 50/60 Hz for 3 phases motors
3 hp at 115 V AC 50/60 Hz for 1 phase motors
30 hp at 460/480 V AC 50/60 Hz for 3 phases motors
Mounting support Plate
Rail
power dissipation per pole 2.4 W AC-3
5.4 W AC-1
2.4 W AC-3e
depth 120 mm
inrush power in w 19 W (at 20 °C)
mechanical durability 10 Mcycles
electrical durability 0.7 Mcycles 60 A AC-1 at Ue <= 440 V
1.5 Mcycles 40 A AC-3 at Ue <= 440 V
1.5 Mcycles 40 A AC-3e at Ue <= 440 V
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
800 A at 440 V for power circuit conforming to IEC 60947
Pollution degree 3
Maximum operating rate 3600 cyc/h 60 °C
operating time 42.5...57.5 ms closing
16...24 ms opening
minimum switching voltage 17 V for signalling circuit
non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Protective cover With
coil technology Built-in bidirectional peak limiting diode suppressor
Pole contact composition 3 NO
Poles description 3P
Utilisation category AC-4
AC-1
AC-3
AC-3e
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Signalling circuit frequency 25...400 Hz
Environment
Climatic withstand conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
ip degree of protection IP20 front face conforming to IEC 60529
operating altitude 0...3000 m
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Range of product TeSys Deca
overvoltage category III
standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1
fire resistance 850 °C conforming to IEC 60695-2-1
protective treatment TH conforming to IEC 60068-2-30
insulation resistance > 10 MOhm for signalling circuit
About this product

The LC1D40A3BD - Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 40A, 24VDC standard coil, spring is developed to cover the obligations of trade buyers, such as panel manufacturers, cable technicians, management services, and industry fabricators. LC1D40A3BD provides extraordinary quality and asset for planners in the electrical and automation industry. This Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 40A, 24VDC standard coil, spring and other TeSyS Deca Contactors from Schneider Electric are procurable at the most favorable cost and shipment duration through BALTELEC.EU, an independent purveyor supporting professionals in their collection needs.

Contractors who have used Schneider Electric TeSyS Deca Contactors have persistently extolled the manufacturer’s stability. It has been outlined that the remarkable functionality of LC1D40A3BD - Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 40A, 24VDC standard coil, spring extends to a array of deployments. Its high-end elements make it great solution to meet diverse demands, promoting success in your industrial, tertiary, and automation efforts.

BaltElec focuses in providing for industrial and tertiary professionals’ needs. We comprehend the particular expectations and preferences of our partners in the realm. By aligning with our company, your organization gain access to the top price and supply timeline of high-quality products like LC1D40A3BD - Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 40A, 24VDC standard coil, spring from Schneider Electric at a budget-friendly price. Registered customers take pleasure in special savings and exclusive assistance.

Get started and secure LC1D40A3BD - Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 40A, 24VDC standard coil, spring at our secure and streamlined website. Don't delay in making this shrewd choice that certifies the superior quality and fulfills the distinct specifications of buyers like you.

Should you experience any inquiries or concerns about LC1D40A3BD - Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 40A, 24VDC standard coil, spring or any other Schneider Electric products, call us or refer to our Knowledge base section below. We have gathered answers to popular doubts to guide you further in making an knowledgeable decision about industrial and tertiary electrical components.

Remember, LC1D40A3BD - Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 40A, 24VDC standard coil, spring from Schneider Electric is trustworthy, budget-friendly, and better to other brands in the TeSyS Deca Contactors category. Make it a part of your arrangement now. Acquire at BALTELEC, your dependable vendor for all your professional electrical equipment and automation needs.

In our Baltelec.eu digital store you will find Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 40A, 24VDC standard coil, spring - LC1D40A3BD worth 166.34 €, which will be a reliable and fashionable solution for your wants. This item is designed by the Schneider Electric brand using the newest technologies and complies with the optimal standards of well-being and competence. We give commodities from the TeSyS Deca Contactors category that integrate resilience and effectiveness, which is an superior selection for various roles. Not minding of whether you necessitate gear for small output or for proficient industrial purpose, Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 40A, 24VDC standard coil, spring will be a constant assistant in your endeavor.

Baltelec ventures to make the procuring process as easy and fast as viable for our clients. We offer detailed explanations and high-quality photographs of Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 40A, 24VDC standard coil, spring so that you can make an aware choice. A team of connoisseurs is always ready to help you with any doubts in the TeSyS Deca Contactors section connected to the electing and use of commodities. We are positive that Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 40A, 24VDC standard coil, spring will meet your expectations and become an important element of your gear for just 166.34 €.

Frequently Asked Questions about Schneider Electric Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 40A, 24VDC standard coil, spring:

Recently viewed
LC1D40A3BD - Schneider Electric
Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 40A, 24VDC standard coil, spring
136,34 € excl. VAT
169,06 € incl. VAT
Pending restock