All categories
Compare Cart

LC1D40004M7 - Contactor TeSys Deca 4 poles AC1 440V 60 A coil 220 V AC - Schneider Electric

Expected in 2-4 weeks
LC1D40004M7 - Contactor TeSys Deca 4 poles AC1 440V 60 A coil 220 V AC - Schneider Electric - Contactor TeSys Deca 4 poles AC1 440V 60 A coil 220 V AC - Schneider Electric - 0
LC1D40004M7 - Contactor TeSys Deca 4 poles AC1 440V 60 A coil 220 V AC - Schneider Electric
320,24 €
320,24 € incl. VAT
Text About:
Contactor TeSys Deca 4 poles AC1 440V 60 A coil 220 V AC - Schneider Electric
320,24 €
SPECIFICATIONS
Main
Contactor application Resistive load
Device short name LC1D
[uc] control circuit voltage 220 V AC 50/60 Hz
[ui] rated insulation voltage Control circuit: 600 V CSA certified
Control circuit: 600 V UL certified
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Control circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-1
control circuit type AC at 50/60 Hz standard
average impedance 1.5 mOhm - Ith 60 A 50 Hz for power circuit
Complementary
[ie] rated operational current 60 A (at <60 °C) AC AC-1 for power circuit
[ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
compatibility code LC1D
[ics] rated service breaking capacity 800 A at 440 V for power circuit conforming to IEC 60947
[ith] conventional thermal current 10 A (at 60 °C) for control circuit
60 A (at 60 °C) for power circuit
Product certifications CSA
UL
CCC
BV
DNV
GOST
RINA
LROS (Lloyds register of shipping)
GL
UKCA
Handle front plate colour 127 mm
Product or component type Contactor
tightening torque Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver Philips No 2
Power circuit: 5 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm
Power circuit: 5 N.m - on screw clamp terminal - with screwdriver flat Ø 8 mm
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Connections - terminals Control circuit: screw clamp terminal 1 1…4 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminal 2 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminal 2 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminal 2 1…4 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminal 1 1…35 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminal 2 1…25 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminal 2 1…35 mm² - cable stiffness: solid without cable end
minimum switching current 5 mA for control circuit
Associated fuse rating 10 A gG for control circuit conforming to IEC 60947-5-1
80 A gG at <= 690 V coordination type 1 for power circuit
80 A gG at <= 690 V coordination type 2 for power circuit
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Control circuit voltage limits 0.3...0.6 Uc (60 °C):drop-out AC 50/60 Hz
0.8...1.1 Uc (60 °C):operational AC 50 Hz
0.85...1.1 Uc (60 °C):operational AC 60 Hz
width (w) 85 mm
mechanical robustness Shocks contactor open (8 Gn for 11 ms)
Shocks contactor closed (10 Gn for 11 ms)
Vibrations contactor opened (2 Gn, 5...300 Hz)
Vibrations contactor closed (4 Gn, 5...300 Hz)
Flame retardance V1 conforming to UL 94
Heat dissipation 4…5 W at 50/60 Hz for control circuit
Net weight 1.44 kg
Hold-in power consumption in va 13 VA 60 Hz cos phi 0.3 (at 20 °C)
15 VA 50 Hz cos phi 0.3 (at 20 °C)
Mounting support Rail
Plate
power dissipation per pole 5.4 W AC-1
depth 125 mm
Inrush power in va 140 VA cos phi 0.75 (at 20 °C)
160 VA cos phi 0.75 (at 20 °C)
mechanical durability 6000000 cycles
Irms rated making capacity 140 A AC for control circuit conforming to IEC 60947-5-1
800 A at 440 V for power circuit conforming to IEC 60947
Maximum operating rate 3600 cyc/h 60 °C
operating time 12...26 ms closing
4...19 ms opening
minimum switching voltage 17 V for control circuit
non-overlap time 1.5 ms on de-energisation between NC and NO contacts
1.5 ms on energisation between NC and NO contacts
Protective cover With
coil technology Without built-in bidirectional peak limiting diode suppressor
Pole contact composition 4 NO
Poles description 4P
Utilisation category AC-1
AC-3
AC-3e
AC-4
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Environment
ip degree of protection IP2X conforming to IEC 60529
IP2X conforming to VDE 0106
operating altitude 3000 m without derating
Permissible ambient air temperature around the device -5…60 °C
-40…70 °C at Uc
Range of product TeSys Deca
overvoltage category III
standards IEC 60947-4-1
EN 60947-5-1
EN 60947-4-1
IEC 60947-5-1
UL 508
CSA C22.2 No 14
fire resistance 850 °C conforming to IEC 60695-2-1
protective treatment TH (pollution degree 3) conforming to IEC 60068
insulation resistance > 10 MOhm for control circuit
Recently viewed
320,24 €
320,24 € incl. VAT
Expected in 2-4 weeks