All categories
Compare Cart

LC1D186BLS207 - TeSys Deca contactor S207 3P (3NO) AC3/AC3e 18A <=440V coil 24V DC low - Schneider Electric

Expected in 2-4 weeks
LC1D186BLS207 - TeSys Deca contactor S207 3P (3NO) AC3/AC3e 18A <=440V coil 24V DC low - Schneider Electric - TeSys Deca contactor S207 3P (3NO) AC3/AC3e 18A <=440V coil 24V DC low - Schneider Electric - 0
LC1D186BLS207 - TeSys Deca contactor S207 3P (3NO) AC3/AC3e 18A <=440V coil 24V DC low - Schneider Electric
118,55 €
118,55 € incl. VAT
Text About:
TeSys Deca contactor S207 3P (3NO) AC3/AC3e 18A <=440V coil 24V DC low - Schneider Electric
118,55 €
SPECIFICATIONS
Main
Contactor application Motor control
Resistive load
Device short name LC1D
Range TeSys
TeSys Deca
[ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-1
control circuit type DC low consumption
motor power kW 4 kW at 220/230 V AC 50 Hz (AC-3)
7.5 kW at 380/400 V AC 50 Hz (AC-3)
9 kW at 415 V AC 50 Hz (AC-3)
9 kW at 440 V AC 50 Hz (AC-3)
10 kW at 500 V AC 50 Hz (AC-3)
10 kW at 660/690 V AC 50 Hz (AC-3)
4 kW at 220/230 V AC 50 Hz (AC-3e)
7.5 kW at 380/400 V AC 50 Hz (AC-3e)
9 kW at 415 V AC 50 Hz (AC-3e)
9 kW at 440 V AC 50 Hz (AC-3e)
10 kW at 500 V AC 50 Hz (AC-3e)
10 kW at 660/690 V AC 50 Hz (AC-3e)
average impedance 2.5 mOhm - Ith 32 A 50 Hz for power circuit
Complementary
[ie] rated operational current 18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
18 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
compatibility code LC1D
[ics] rated service breaking capacity 300 A at 440 V for power circuit conforming to IEC 60947
[ith] conventional thermal current 10 A (at 60 °C) for signalling circuit
32 A (at 60 °C) for power circuit
Product certifications IEC
CCC
EAC
UA
TR
UKCA
Handle front plate colour 77 mm
Product or component type Contactor
tightening torque Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5
Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5
Power circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5
Power circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5
Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 M3.5
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 M3.5
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Auxiliary contact composition 1 NO + 1 NC
Connections - terminals Control circuit: lugs-ring terminals - external diameter: 8 mm
Power circuit: lugs-ring terminals - external diameter: 9.5 mm
minimum switching current 5 mA for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
50 A gG at <= 690 V coordination type 1 for power circuit
35 A gG at <= 690 V coordination type 2 for power circuit
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
contact compatibility M5
Control circuit voltage limits 0.1...0.25 Uc (-40…70 °C):drop-out DC
0.7...1.25 Uc (-40…70 °C):operational DC
width (w) 45 mm
mechanical robustness Vibrations contactor open (2 Gn, 5...300 Hz)
Vibrations contactor closed (4 Gn, 5...300 Hz)
Shocks contactor open (10 Gn for 11 ms)
Shocks contactor closed (15 Gn for 11 ms)
Net weight 0.33 kg
time constant 37 ms
Hold-in power consumption in w 4 W at 20 °C
Mounting support Plate
Rail
power dissipation per pole 2.5 W AC-1
0.8 W AC-3
0.8 W AC-3e
depth 95 mm
inrush power in w 4 W (at 20 °C)
mechanical durability 30 Mcycles
electrical durability 1.65 Mcycles 18 A AC-3 at Ue <= 440 V
1 Mcycles 32 A AC-1 at Ue <= 440 V
1.65 Mcycles 18 A AC-3e at Ue <= 440 V
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
300 A at 440 V for power circuit conforming to IEC 60947
Maximum operating rate 3600 cyc/h 60 °C
operating time 55...75 ms closing
16...32 ms opening
minimum switching voltage 17 V for signalling circuit
non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Protective cover With
coil technology With integral suppression device
Pole contact composition 3 NO
Poles description 3P
Utilisation category AC-1
AC-3
AC-3e
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Environment
Ambient air temp for storage/transportation -60…80 °C
Climatic withstand conforming to IACS E10
conforming to IEC 60947-1 Annex Q category D
operating altitude 0...3000 m
Range of product TeSys Deca
overvoltage category III
standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
EN 45545: R22 HL3
EN 45545: R26 HL3
DIN 5510-2
fire resistance 850 °C conforming to IEC 60695-2-1
insulation resistance > 10 MOhm for signalling circuit
Recently viewed
118,55 €
118,55 € incl. VAT
Expected in 2-4 weeks