Text About:
Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 18A, 24VAC 50/60Hz coil, spring - Schneider Electric
55,91 €
SPECIFICATIONS
Main
Contactor application Motor control
Resistive load
Device short name LC1D
[uc] control circuit voltage 24 V AC 50/60 Hz
[ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
control circuit type AC at 50/60 Hz
motor power kW 4 kW at 220...230 V AC 50/60 Hz (AC-3)
7.5 kW at 380...400 V AC 50/60 Hz (AC-3)
9 kW at 415...440 V AC 50/60 Hz (AC-3)
10 kW at 500 V AC 50/60 Hz (AC-3)
10 kW at 660...690 V AC 50/60 Hz (AC-3)
4 kW at 400 V AC 50/60 Hz (AC-4)
4 kW at 220...230 V AC 50/60 Hz (AC-3e)
7.5 kW at 380...400 V AC 50/60 Hz (AC-3e)
9 kW at 415...440 V AC 50/60 Hz (AC-3e)
10 kW at 500 V AC 50/60 Hz (AC-3e)
10 kW at 660...690 V AC 50/60 Hz (AC-3e)
average impedance 2.5 mOhm - Ith 25 A 50 Hz for power circuit
Complementary
[ie] rated operational current 18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
18 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
Power circuit: <= 300 V DC
compatibility code LC1D
[ics] rated service breaking capacity 300 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current 145 A 40 °C - 10 s for power circuit
240 A 40 °C - 1 s for power circuit
40 A 40 °C - 10 min for power circuit
84 A 40 °C - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
[ith] conventional thermal current 25 A (at 60 °C) for power circuit
10 A (at 60 °C) for signalling circuit
Product certifications UL
BV
LROS (Lloyds register of shipping)
RINA
CSA
CCC
GOST
DNV
GL
UKCA
Handle front plate colour 99 mm
Product or component type Contactor
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Auxiliary contact composition 1 NO + 1 NC
Connections - terminals Control circuit: spring terminals 1 2.5 mm² - cable stiffness: flexible without cable end
Control circuit: spring terminals 2 2.5 mm² - cable stiffness: flexible without cable end
Power circuit: spring terminals 1 4 mm² - cable stiffness: flexible without cable end
Power circuit: spring terminals 2 4 mm² - cable stiffness: flexible without cable end
minimum switching current 5 mA for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
50 A gG at <= 690 V coordination type 1 for power circuit
35 A gG at <= 690 V coordination type 2 for power circuit
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
contact compatibility M2
Control circuit voltage limits 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
width (w) 45 mm
mechanical robustness Vibrations contactor open (2 Gn, 5...300 Hz)
Vibrations contactor closed (4 Gn, 5...300 Hz)
Shocks contactor open (10 Gn for 11 ms)
Shocks contactor closed (15 Gn for 11 ms)
Flame retardance V1 conforming to UL 94
Heat dissipation 2…3 W at 50/60 Hz
Net weight 0.33 kg
Hold-in power consumption in va 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C)
Motor power hp 1 hp at 115 V AC 50/60 Hz for 1 phase motors
3 hp at 230/240 V AC 50/60 Hz for 1 phase motors
5 hp at 200/208 V AC 50/60 Hz for 3 phases motors
5 hp at 230/240 V AC 50/60 Hz for 3 phases motors
10 hp at 460/480 V AC 50/60 Hz for 3 phases motors
15 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Mounting support Plate
Rail
power dissipation per pole 2.5 W AC-1
0.8 W AC-3
0.8 W AC-3e
depth 86 mm
Inrush power in va 70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C)
mechanical durability 15 Mcycles
electrical durability 1.65 Mcycles 18 A AC-3 at Ue <= 440 V
1 Mcycles 32 A AC-1 at Ue <= 440 V
1.65 Mcycles 25 A AC-3e at Ue <= 440 V
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
300 A at 440 V for power circuit conforming to IEC 60947
Pollution degree 3
Maximum operating rate 3600 cyc/h 60 °C
operating time 12...22 ms closing
4...19 ms opening
minimum switching voltage 17 V for signalling circuit
non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Protective cover With
coil technology Without built-in suppressor module
Pole contact composition 3 NO
Poles description 3P
Utilisation category AC-3
AC-4
AC-1
AC-3e
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Signalling circuit frequency 25...400 Hz
Environment
Climatic withstand conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
ip degree of protection IP20 front face conforming to IEC 60529
operating altitude 0...3000 m
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Range of product TeSys Deca
overvoltage category III
standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1
fire resistance 850 °C conforming to IEC 60695-2-1
protective treatment TH conforming to IEC 60068-2-30
insulation resistance > 10 MOhm for signalling circuit
About this product

The LC1D183B7 - Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 18A, 24VAC 50/60Hz coil, spring is created to satisfy the needs of industry experts, such as control panel builders, electrical fitters, upkeep firms, and Original Equipment manufacturers. LC1D183B7 dispenses extraordinary excellence and advantages for designers in the power systems industry. This Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 18A, 24VAC 50/60Hz coil, spring and other TeSyS Deca Contactors from Schneider Electric can be bought at the most economical price and delivery period through BALTELEC, a well-regarded wholesaler meeting the needs of engineers in their collection needs.

Professionals who have secured Schneider Electric TeSyS Deca Contactors have consistently approved the manufacturer’s robustness. It has been mentioned that the superlative effectiveness of LC1D183B7 - Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 18A, 24VAC 50/60Hz coil, spring extends to a spectrum of implementations. Its superior components make it great solution for assorted uses, ensuring your industrial, tertiary and automation projects success.

BaltElec team concentrates in catering industrial and tertiary professionals’ needs. We know the specific specifications and desires of our consumers in the sector. By partnering with BALTELEC, your company get access to the top rates and supply timeline of the top-of-the-line products like LC1D183B7 - Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 18A, 24VAC 50/60Hz coil, spring from Schneider Electric at a competitive price. Registered users take advantage of added discounts and preferred assistance.

Begin today and order LC1D183B7 - Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 18A, 24VAC 50/60Hz coil, spring at our well-established and hassle-free virtual storefront. Don't delay in making this clever action that affirms the greatest quality and complies with the specific standards of suppliers like your company.

If you encounter any queries or concerns about LC1D183B7 - Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 18A, 24VAC 50/60Hz coil, spring or any other Schneider Electric products, contact us or refer to our FAQs section below. We have consolidated answers to common issues to support you further in making an thoughtful decision about industrial and tertiary electrical components.

Remember, LC1D183B7 - Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 18A, 24VAC 50/60Hz coil, spring from Schneider Electric is dependable, inexpensive, and superior to its counterparts in the TeSyS Deca Contactors category. Feel free to make it a part of your infrastructure right now. Snap up at Baltelec webstore, your faithful dealer for all your TeSyS Deca Contactors.

In our Baltelec.eu virtual store you will identify Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 18A, 24VAC 50/60Hz coil, spring - LC1D183B7 worth 55.01 €, which will be a reliable and modern solution for your wishes. This produce is constructed by the Schneider Electric brand using the advanced technologies and obeys the premier standards of reliability and productivity. We provide items from the TeSyS Deca Contactors category that fuse durability and utility, which is an top-notch election for various operations. Irrespective of whether you seek equipment for small creation or for professional industrial exploitation, Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 18A, 24VAC 50/60Hz coil, spring will be a safe helper in your work.

Baltelec works to make the securing process as convenient and fast as achievable for our patrons. We offer detailed summaries and high-quality images of Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 18A, 24VAC 50/60Hz coil, spring so that you can make an briefed choice. A team of specialists is always ready to help you with any enquiries in the TeSyS Deca Contactors section related to the deciding and use of articles. We are affirmed that Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 18A, 24VAC 50/60Hz coil, spring will meet your anticipations and become an indispensable element of your device for just 55.01 €.

Popular Questions about Schneider Electric LC1D183B7:

Recently viewed
LC1D183B7 - Schneider Electric
Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 18A, 24VAC 50/60Hz coil, spring
45,09 € excl. VAT
55,91 € incl. VAT
Expected in 2-4 weeks