All categories
Compare Cart

LC1D115004BD - TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 200 A 24 V DC standard coil - Schneider Electric

Expected in 2-4 weeks
LC1D115004BD - TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 200 A 24 V DC standard coil - Schneider Electric - TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 200 A 24 V DC standard coil - Schneider Electric - 0
LC1D115004BD - TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 200 A 24 V DC standard coil - Schneider Electric
483,89 € excl. VAT
590,35 € incl. VAT
Text About:
TeSys Deca contactor 4P(4 NO) AC1 <= 440 V 200 A 24 V DC standard coil - Schneider Electric
590,35 €
SPECIFICATIONS
Main
Contactor application Resistive load
Device short name LC1D
Range TeSys
[uc] control circuit voltage 24 V DC
[ui] rated insulation voltage Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Power circuit: 1000 V conforming to IEC 60947-4-1
control circuit type DC standard
average impedance 0.6 mOhm - Ith 200 A 50 Hz for power circuit
Complementary
[ie] rated operational current 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[ue] rated operational voltage Power circuit: <= 1000 V AC 25...400 Hz
Power circuit: <= 460 V DC
compatibility code LC1D
[ics] rated service breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current 250 A 40 °C - 10 min for power circuit
550 A 40 °C - 1 min for power circuit
950 A 40 °C - 10 s for power circuit
1100 A 40 °C - 1 s for power circuit
[ith] conventional thermal current 200 A (at 60 °C) for power circuit
Product certifications RINA
GOST
GL
CCC
DNV
BV
CSA
UL
LROS (Lloyds register of shipping)
UKCA
Handle front plate colour 158 mm
Product or component type Contactor
tightening torque Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 12 N.m - on connector hexagonal screw head 4 mm
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
Connections - terminals Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: solid without cable end
Power circuit: connector 1 10…120 mm² - cable stiffness: flexible without cable end
Power circuit: connector 2 10…50 mm² - cable stiffness: flexible without cable end
Power circuit: connector 1 10…120 mm² - cable stiffness: flexible with cable end
Power circuit: connector 2 10…50 mm² - cable stiffness: flexible with cable end
Power circuit: connector 1 10…120 mm² - cable stiffness: solid without cable end
Power circuit: connector 2 10…50 mm² - cable stiffness: solid without cable end
Associated fuse rating 250 A gG at <= 690 V coordination type 1 for power circuit
200 A gG at <= 690 V coordination type 2 for power circuit
contact compatibility M8
Control circuit voltage limits 0.75...1.2 Uc (-40…55 °C):operational DC
0.15...0.4 Uc (-40…70 °C):drop-out DC
1...1.2 Uc (55…70 °C):operational DC
width (w) 150 mm
mechanical robustness Vibrations contactor open (2 Gn, 5...300 Hz)
Vibrations contactor closed (4 Gn, 5...300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (6 Gn for 11 ms)
Flame retardance V1 conforming to UL 94
Net weight 2.86 kg
time constant 25 ms
Hold-in power consumption in w 2.4…5.1 W at 20 °C
Mounting support Rail
Plate
power dissipation per pole 24 W AC-1
depth 132 mm
inrush power in w 270…365 W (at 20 °C)
mechanical durability 8 Mcycles
electrical durability 0.8 Mcycles 200 A AC-1 at Ue <= 440 V
Irms rated making capacity 1260 A at 440 V for power circuit conforming to IEC 60947
Pollution degree 3
Maximum operating rate 1200 cyc/h 60 °C
operating time 20...35 ms closing
40...75 ms opening
Protective cover With
coil technology With integral suppression device
Pole contact composition 4 NO
Poles description 4P
Utilisation category AC-1
AC-3
AC-3e
AC-4
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Environment
Climatic withstand conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
ip degree of protection IP20 front face conforming to IEC 60529
operating altitude 0...3000 m
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Range of product TeSys Deca
overvoltage category III
standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
fire resistance 850 °C conforming to IEC 60695-2-1
protective treatment TH conforming to IEC 60068-2-30
Recently viewed
483,89 € excl. VAT
590,35 € incl. VAT
Expected in 2-4 weeks