LADS2 - Time delay contact block,TeSys Deca,1NO+1NC,on-delay 1-30s,front,with 40±15ms switching time between NC opening and NO closing - Schneider Electric - Time delay contact block,TeSys Deca,1NO+1NC,on-delay 1-30s,front,with 40±15ms switching time between NC opening and NO closing - Schneider Electric - 0
LADS2 - Time delay contact block,TeSys Deca,1NO+1NC,on-delay 1-30s,front,with 40±15ms switching time between NC opening and NO closing - Schneider Electric - Time delay contact block,TeSys Deca,1NO+1NC,on-delay 1-30s,front,with 40±15ms switching time between NC opening and NO closing - Schneider Electric - 0
Pending restock

LADS2 – Schneider Electric

EAN: 3389110386103
49,70 € excl. VAT
61,63 € incl. VAT
Time delay contact block,TeSys Deca,1NO+1NC,on-delay 1-30s,front,with 40±15ms switching time between NC opening and NO closing - Schneider Electric
61,63 €
SPECIFICATIONS
Default
Series TeSyS Deca Contactors
Main
Range TeSys
TeSys Deca
type of product or equipment Bloc de contact auxiliaire temporisation
composition of the poles 1F+1O
Product Name TeSys D
TeSys Deca
[ui] rated insulation voltage 690 V se conformer à CEI 60947-5-1
600 V se conformer à UL 60947-5-1
600 V se conformer à CSA C22.2 No 60947-5-1
type of timer Travail
Complementary
[ie] rated operational current 6 A à 120 V AC-15
1,04 A à 690 V AC-15
0,55 A à 125 V DC-13
0,1 A à 600 V DC-13
[ue] rated operational voltage 690 V CA 25...400 Hz
application Démarreur étoile-triangle
range compatibility TeSys D CAD
TeSys D LC1D
TeSys F LC1F
TeSys F CR1F
TeSys Deca CAD
TeSys Deca LC1D
[ith] conventional thermal current 10 A à <60 °C)
allowable temporary current 100 A 60 °C 1s
120 A 60 °C 500 ms
140 A 60 °C 100 ms
Handle front plate colour 48 mm
tightening torque 1,7 N.m - avec tournevis plat Ø 6 mm
1,7 N.m - avec tournevis cruciforme Philips n° 2
1,7 N.m - avec tournevis pozidriv n°2
mounting location Façade
minimum switching current 5 mA
connection mode Borniers à vis-étrier 1 câble(s) 1…2,5 mm²souple avec extrémité de câble
Borniers à vis-étrier 1 câble(s) 1…2,5 mm²souple sans extrémité de câble
Borniers à vis-étrier 2 câble(s) 1…2,5 mm²souple avec extrémité de câble
Borniers à vis-étrier 2 câble(s) 1…2,5 mm²souple sans extrémité de câble
Borniers à vis-étrier 1 câble(s) 1…2,5 mm²rigide
Borniers à vis-étrier 2 câble(s) 1…2,5 mm²rigide
Borniers à vis-étrier
contact operation Temps de réponse
mechanical endurance 5 Mcycles
width (w) 44 mm
Colour Gris foncé
timing range 1…30 s
rated rms inrush power 140 A à <= 690 V CA se conformer à CEI 60947-5-1
250 A à <= 690 V CC se conformer à CEI 60947-5-1
depth 61 mm
minimum switching voltage 17 V
kind of protection Fusible gG 10 A
non-overlap time 1,5 ms sur désexcitation non-chevauchement entre contact NC et NO
1,5 ms sur excitation non-chevauchement entre contact NC et NO
Environment
environment characteristic Environnement normal
ip degree of protection IP20 se conformer à CEI 60529
operating altitude 3000 m
product certificates certificat CEI CE
UL
CSA
CCC
EAC
UKCA
standards CSA C22.2 No 60947-5-1
GB/T 14048.5
EN/CEI 60947-5-1
operating ambient air temperature -40…70 °C
storage room temperature -60…80 °C
protective treatment TH se conformer à CEI 60068
insulation resistance > 10 MΩ
Q&A and product info

Contact Us

Professional sales of electrical equipment in Estonia, Latvia, Lithuania, and Finland. Certified low-voltage components, circuit breakers, contactors, and industrial automation solutions. Same-day quotations and fast delivery across the Baltics and Finland.

Baltelec
+372 5326 4976

Mon–Fri 9:00–17:00

info@baltelec.eu

Response within 2 hours

Schneider Electric LADS2 is a professional TeSyS Deca Contactors product designed for companies. BaltElec specializes in wholesale and product distribution in Estonia, Latvia, Lithuania, and Finland.

  • Original Schneider Electric product, documentation available on request.
  • Project pricing – request a quote for larger quantities (MOQ may apply).
  • Efficient logistics across the Baltics and Finland; cooperation with logistics partners.
  • Technical support and application suitability advice based on your requirements.

Pricing: Request a project quote. The price depends on quantity, delivery, and payment terms.

TeSyS Deca Contactors specifications may vary by configuration. For an exact match, please send us your requirements or check the technical data sheet.

FAQ for LADS2 - Schneider Electric

Recently viewed
LADS2 - Schneider Electric
Time delay contact block,TeSys Deca,1NO+1NC,on-delay 1-30s,front,with 40±15ms switching time between NC opening and NO closing
49,70 € excl. VAT
61,63 € incl. VAT
Pending restock