LADR43 - Time delay auxiliary contact block, TeSys Deca, 1NO + 1NC, off delay 10180s, front, spring terminals - Schneider Electric

Expected in 2-4 weeks
LADR43 - Time delay auxiliary contact block, TeSys Deca, 1NO + 1NC, off delay 10180s, front, spring terminals - Schneider Electric - Time delay auxiliary contact block, TeSys Deca, 1NO + 1NC, off delay 10180s, front, spring terminals - Schneider Electric - 0
LADR43 - Time delay auxiliary contact block, TeSys Deca, 1NO + 1NC, off delay 10180s, front, spring terminals - Schneider Electric
73,89 €
73,89 € incl. VAT
Text About:
Time delay auxiliary contact block, TeSys Deca, 1NO + 1NC, off delay 10180s, front, spring terminals - Schneider Electric
73,89 €
SPECIFICATIONS
Main
Contacts operation Time delay
Range TeSys
TeSys Deca
Product Name TeSys Deca
timer type Off delay
[ui] rated insulation voltage 690 V conforming to IEC 60947-5-1
600 V conforming to UL 60947-5-1
600 V conforming to CSA C22.2 No 60947-5-1
Complementary
[ie] rated operational current 6 A at 120 V AC-15
1.04 A at 690 V AC-15
0.55 A at 125 V DC-13
0.1 A at 600 V DC-13
[ue] rated operational voltage 690 V AC 25...400 Hz
range compatibility TeSys D CAD
TeSys D LC1D
TeSys Deca CAD
TeSys Deca LC1D
[ith] conventional thermal current 10 A (at 60 °C)
Product certifications IECEE CB Scheme
UL
CSA
CCC
EAC
UKCA
Handle front plate colour 48 mm
Product or component type Time delay auxiliary contact block
mounting location Front
Connections - terminals Spring terminals 2 cable(s) 2.5 mm²flexible without cable end
Spring terminals 2 cable(s) 2.5 mm²rigid without cable end
minimum switching current 5 mA
width (w) 44 mm
Colour Dark grey
depth 61 mm
mechanical durability 5 Mcycles
Irms rated making capacity 140 A AC
250 A DC
Permissible short-time rating 100 A 60 °C 1 s
120 A 60 °C 500 ms
140 A 60 °C 100 ms
Time delay range 10...180 s
minimum switching voltage 17 V
non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact
1.5 ms on energisation no overlap between NC and NO contact
Pole contact composition 1 NO + 1 NC
Protection type GG fuse 10 A
Environment
Ambient air temp for storage/transportation -60…80 °C
ip degree of protection IP20 conforming to IEC 60529
operating altitude 3000 m
ambient air temperature for operation -40…70 °C
Environmental characteristics Normal environment
standards EN/IEC 60947-5-1
UL 60947-5-1
CSA C22.2 No 60947-5-1
GB/T 14048.5
EN/IEC 60947-5-1
protective treatment TH conforming to IEC 60068
insulation resistance > 10 MOhm