All categories
Compare Cart

K1E005A - Cam switch body, Harmony K, Ш 22mm, plastic, 5 pole, with 0 position, 45°, 12A - Schneider Electric

Expected in 2-4 weeks
K1E005A - Cam switch body, Harmony K, Ш 22mm, plastic, 5 pole, with 0 position, 45°, 12A - Schneider Electric - Cam switch body, Harmony K, Ш 22mm, plastic, 5 pole, with 0 position, 45°, 12A - Schneider Electric - 0
K1E005A - Cam switch body, Harmony K, Ш 22mm, plastic, 5 pole, with 0 position, 45°, 12A - Schneider Electric
27,43 € excl. VAT
33,46 € incl. VAT
Text About:
Cam switch body, Harmony K, Ш 22mm, plastic, 5 pole, with 0 position, 45°, 12A - Schneider Electric
33,46 €
SPECIFICATIONS
Main
Cam switch function Switch
[ithe] thermal current under enclosure 10 A
Off position With Off position
Sub-assembly composition Contact blocks + fixing plate
[ui] rated insulation voltage 690 V (pollution degree 3) conforming to IEC 60947-1
Switching positions Right: 0° - 45°
component name K1
Complementary
[ie] rated operational current ac 1.8 A at 690 V AC-3 3 phases conforming to IEC 947-3
2.8 A at 500 V AC-3 3 phases conforming to IEC 947-3
2.8 A at 690 V AC-23A 3 phases conforming to IEC 947-3
3.3 A at 400 V AC-3 3 phases conforming to IEC 947-3
3.8 A at 500 V AC-23A 3 phases conforming to IEC 947-3
4.6 A at 230 V AC-3 3 phases conforming to IEC 947-3
4.8 A at 400 V AC-23A 3 phases conforming to IEC 947-3
5.6 A at 230 V AC-23A 3 phases conforming to IEC 947-3
1 A at 500 V AC-15 conforming to IEC 947-5-1
2 A at 400 V AC-15 conforming to IEC 947-5-1
3 A at 230 V AC-15 conforming to IEC 947-5-1
[ith] conventional thermal current 12 A
Product certifications CSA 240 V 3 hp 3 phases 2 -pole(s)
UL 240 V 0.33 hp 1 phase 2 -pole(s)
CSA 240 V 1 hp 1 phase
UL 240 V 1 hp 3 phases
Product or component type Cam switch body
[uimp] rated impulse withstand voltage 4 kV in isolating function
6 kV conforming to IEC 947-1
mounting location Front
switching angle 45 °
bezel material Plastic
contact operation Slow-break
Fixing mode Ø 22 mm hole
rated operational power in w 10500 W AC-21, 500 - 660 V 3 phases conforming to IEC 947-3
1100 W AC-3, 230 V 3 phases conforming to IEC 947-3
1500 W AC-23A, 230 V 3 phases conforming to IEC 947-3
1500 W AC-3, 400 V 1 phase conforming to IEC 947-3
1500 W AC-3, 400 V 3 phases conforming to IEC 947-3
1500 W AC-3, 500 V 3 phases conforming to IEC 947-3
1500 W AC-3, 690 V 3 phases conforming to IEC 947-3
2200 W AC-23A, 400 V 3 phases conforming to IEC 947-3
2200 W AC-23A, 500 V 3 phases conforming to IEC 947-3
2200 W AC-23A, 690 V 3 phases conforming to IEC 947-3
4800 W AC-21, 230 V 3 phases conforming to IEC 947-3
600 W AC-3, 230 V 1 phase conforming to IEC 947-3
8300 W AC-21, 400 V 3 phases conforming to IEC 947-3
Net weight 0.13 kg
mechanical durability 1000000 cycles
electrical durability 1000000 cycles AC-15
1000000 cycles AC-21
500000 cycles AC-23
500000 cycles AC-3
Positive opening With
electrical connection Captive screw clamp terminals flexible, clamping capacity: 2 x 1.5 mm²
Captive screw clamp terminals solid, clamping capacity: 1 x 2.5 mm²
Maximum operating rate 2.5 cyc/mn AC-21
2.5 cyc/mn AC-23
2.5 cyc/mn AC-3
8.333 cyc/mn AC-15
Short-circuit current 10000 A
Shock resistance 30 gn conforming to IEC 68-2-27
Poles description 5P
Short-circuit protection 16 A cartridge fuse, type gG
Environment
Ambient air temp for storage/transportation -40…70 °C
Range of product Harmony K
ambient air temperature for operation -25…55 °C
overvoltage category Class II conforming to IEC 536
Class II conforming to NF C 20-030
standards EN 60947-3 for power circuit
EN 60947-5-1 for control circuit
IEC 60947-3 for power circuit
IEC 60947-5-1 for control circuit
CENELEC EN 50013
vibration resistance 5 gn conforming to IEC 68-2-6 (f = 10…150 Hz)
protective treatment TC
Recently viewed
27,43 € excl. VAT
33,46 € incl. VAT
Expected in 2-4 weeks