SPECIFICATIONS
Main
Device short name IFL12
Range Vigilohm
number of channels 12
Earthing system IT
threshold setting Alarm: high, medium, low
Complementary
Alarm per channel Alarm threshold: common to all feeders
[ics] rated service breaking capacity 250 V - AC at 6 A
48 V - DC at 1 A
Product certifications DNV-GL
CE
EAC
UL
cULus
response time <= 5 s
Handle front plate colour 110 mm
Product or component type Insulation fault locator
Connections - terminals Power supply: removable screw terminal block0.2…2.5 mm²
Output relay: removable screw terminal block0.2…2.5 mm²
Toroids inputs: removable screw terminal block0.2…1.5 mm²
Cut-out dimensions 92 x 104 mm
Network rated voltage 0…1000 V - AC at 45...65 Hz
0…1000 V - DC
Device application Marine application
Standard environment application
Material Thermoplastic
width (w) 108 mm
Electrical circuit type Power circuit
Local signalling Yellow indicator light: insulation fault
Green/red indicator light: product status
Green indicator light: satisfactory insulation
Yellow flashing indicator light: transient fault
Green indicator light: configured threshold LED
Green indicator light: configured filtering LED
Yellow steady 1 LED per channel: insulation fault
Yellow flashing 1 LED per channel: transient fault/toroid disconnected
Mounting mode Flush-mounted
Clip-on
Net weight 0.5 kg
communication port protocol -
Mounting support Panel
DIN rail
depth 59 mm
Pollution degree 2
Power consumption in va 20 VA
Power consumption in w 6 W
Type of installation Indoor
mounting position Horizontal
Vertical
auxiliary supply voltage 100...440 V DC +/- 15 %
100...440 V AC 45...65 Hz +/- 15 %
Output contact 1 C/O standard
Test function Manual
Auto test at start and every 5h
Environment
Ambient air temp for storage/transportation -40…85 °C
ip degree of protection Case: IP20
Front face: IP54
operating altitude <= 3000 m
ambient air temperature for operation -25…55 °C
Environmental characteristics Exposure to damp heat not in service conforming to IEC 60068-2-30
Exposure to damp heat in service conforming to IEC 60068-2-56
Salt mist conforming to IEC 60068-2-52
overvoltage category III
standards IEC 60364-4-41
IEC 61010-1
IEC 60364-5-51
IEC 61557-9
relative humidity 5…92 %