All categories
Compare Cart

HEF990H - MCCB h1600 3P 70kA 1600A LSI - Hager

Expected in 2-4 weeks
HEF990H - MCCB h1600 3P 70kA 1600A LSI - Hager - MCCB h1600 3P 70kA 1600A LSI - Hager - 0
HEF990H - MCCB h1600 3P 70kA 1600A LSI - Hager
3 550,60 €
3 550,60 € incl. VAT
Text About:
MCCB h1600 3P 70kA 1600A LSI - Hager
3 550,60 €
SPECIFICATIONS
Additional Information
type of order Toggle
type of pole 3P3D
Main
Number of modules 12
rated operational voltage ue 220 / 690 V
Complementary
air humidity protection for all climates
breaking capacity on 1 pole for it 230v nf 60947-2 60 kA
category of use A
complete device with protection unit Yes
connection cross-sect. flexible conductor 3x240mm²
correction factor of rating current for 2 devices placed side-by-side 1
din rail mounting with optional adaptator No
electric endurance in number of cycles 1000
magnetic protection nob setting xin 2.5 / 5 / 10
magnetic trip delay time 100 to 200 ms
motor drive optional Yes
power loss per pole at in 56.3 W
range of the magnetic adjustment 8960 / 11200 / 14000 / 17920 / 19200 / 19200 / 19200 A
search words Compact circuit-breaker;Circuit-breaker;Main switch;Switch;Circuit-breaker;MCCB;
thermal protection trip time 5 / 10 / 11 / 19 / 21 / 29 ms
[in] rated current 1600 A
breaking capacity on 1 pole for it 400v nf 60947-2 9 kA
connection cross-sect. rigid cable 3x240mm²
correction factor of rating current for 3 devices placed side-by-side 1
integrated earth fault protection No
number of mechanical operations 4000
setting type in or ith IrTh
time of response when opening 10 ms
total power loss under in 168.9 W
trip unit LSI
correction factor of rating current for 4 and 5 devices placed side-by-side 1
tripmode LSI
type of connection Terminal
with under voltage release No
correction factor of rating current for 6 devices placed side-by-side 1
rated service breaking capacity ics ac according iec 60947-2 71 %
storage/transport temperature -35…70 °C
rated ultimate short-circuit breaking capacity icu under 230v ac iec 60947-2 100 kA
Rated insulation voltage 800 V
rated ultimate short-circuit breaking capacity icu under 240v ac iec 60947-2 100 kA
connection Front connection
rated ultimate short-circuit breaking capacity icu under 400v ac iec 60947-2 70 kA
rated ultimate short-circuit breaking capacity icu under 415v ac iec 60947-2 70 kA
rated ultimate short-circuit breaking capacity icu under 440v ac iec 60947-2 70 kA
rated ultimate short-circuit breaking capacity icu under 690v ac iec 60947-2 45 kA
thermal protection nob setting xin 0.4 / 0.5 / 0.63 / 0.8 / 0.9 / 0.95 / 1
frequency 50/60
rated impulse withstand voltage 8 kV
Poles description 3 P
Environment
altitude 2000 m
european directive weee concerned
protection index ip IP4X
standard text IEC 60947-2
operating temperature -25…70 °C
Recently viewed
3 550,60 €
3 550,60 € incl. VAT
Expected in 2-4 weeks