HDA161L - MCCB h3 x160 TM 4x160A 18kA - Hager

Expected in 2-4 weeks
HDA161L - MCCB h3 x160 TM 4x160A 18kA - Hager - MCCB h3 x160 TM 4x160A 18kA - Hager - 0
HDA161L - MCCB h3 x160 TM 4x160A 18kA - Hager
189,79 €
189,79 € incl. VAT
Text About:
MCCB h3 x160 TM 4x160A 18kA - Hager
189,79 €
SPECIFICATIONS
Additional Information
type of order Toggle
type of pole 4P4D
Main
Number of modules 6
rated operational voltage ue 220 / 415 V
Complementary
air humidity protection for all climates
breaking capacity on 1 pole for it 230v nf 60947-2 15 kA
category of use A
complete device with protection unit Yes
connection cross-sect. flexible conductor 4 / 70mm²
correction factor of rating current for 2 devices placed side-by-side 1
din rail mounting with optional adaptator No
electric endurance in number of cycles 1000
magnetic trip delay time 0 ms
motor drive optional No
power loss per pole at in 14.6 W
range of the magnetic adjustment 1600 A
thermal protection trip time 0 ms
[in] rated current 160 A
breaking capacity on 1 pole for it 400v nf 60947-2 9 kA
connection cross-sect. rigid cable 4 / 95mm²
correction factor of rating current for 3 devices placed side-by-side 1
integrated earth fault protection No
number of mechanical operations 4000
setting type in or ith IN
time of response when opening 10 ms
total power loss under in 43.8 W
trip unit TM F/F
correction factor of rating current for 4 and 5 devices placed side-by-side 1
tripmode TM
type of connection with screw
with under voltage release No
correction factor of rating current for 6 devices placed side-by-side 1
rated service breaking capacity ics ac according iec 60947-2 100 %
storage/transport temperature -35…70 °C
rated ultimate short-circuit breaking capacity icu under 230v ac iec 60947-2 25 kA
Rated insulation voltage 690 V
rated ultimate short-circuit breaking capacity icu under 240v ac iec 60947-2 25 kA
connection Front connection
rated ultimate short-circuit breaking capacity icu under 400v ac iec 60947-2 18 kA
rated ultimate short-circuit breaking capacity icu under 415v ac iec 60947-2 18 kA
rated ultimate short-circuit breaking capacity icu under 440v ac iec 60947-2 15 kA
rated ultimate short-circuit breaking capacity icu under 690v ac iec 60947-2 4 kA
thermal protection nob setting xin 1
thermal setting current on neutral pole 1 In
frequency 50/60
rated impulse withstand voltage 8 kV
Poles description 4 P
Environment
altitude 2000 m
european directive weee concerned
protection index ip IP4X
standard text IEC 60947-2
operating temperature -25…70 °C