All categories
Compare Cart

GV4PEM25B - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic multifunction, Everlink termin - Schneider Electric

Expected in 2-4 weeks
GV4PEM25B - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic multifunction, Everlink termin - Schneider Electric - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic multifunction, Everlink termin - Schneider Electric - 0
GV4PEM25B - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic multifunction, Everlink termin - Schneider Electric
297,43 € excl. VAT
368,82 € incl. VAT
Text About:
Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic multifunction, Everlink termin - Schneider Electric
368,82 €
SPECIFICATIONS
Main
Device short name GV4PEM
Range TeSys Deca
TeSys Deca
magnetic tripping current 425 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Electronic
Thermal-magnetic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 7.5 kW at 660...690 V AC 50/60 Hz
5.5 kW at 400...415 V AC 50/60 Hz
7.5 kW at 500 V AC 50/60 Hz
9 kW at 660...690 V AC 50/60 Hz
11 kW at 660...690 V AC 50/60 Hz
7.5 kW at 400...415 V AC 50/60 Hz
9 kW at 400...415 V AC 50/60 Hz
11 kW at 400...415 V AC 50/60 Hz
9 kW at 500 V AC 50/60 Hz
11 kW at 500 V AC 50/60 Hz
15 kW at 500 V AC 50/60 Hz
15 kW at 660...690 V AC 50/60 Hz
18.5 kW at 660...690 V AC 50/60 Hz
Complementary
[in] rated current 25 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
35 kA at 240 V AC 50/60 Hz conforming to UL 60947
18 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
14 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Toggle
Product certifications IEC
UL
CSA
CCC
EAC
ATEX
EU-RO MR
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals EverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² - solid
EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² - flexible
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² - solid
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² - flexible
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.45 kg
Operating position Any position
power dissipation per pole 4.6 W
depth 116 mm
mechanical durability 40000 cycles
electrical durability 40000 cycles for AC-3 at 440 V In/2
20000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards CSA C22.2 No 60947-4-1
UL 60947-4-1
EN/IEC 60947-4-1
EN/IEC 60947-2
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4PEM25B - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic multifunction, Everlink termin is crafted to match the demands of specialized professionals, such as switchgear manufacturers, electrical fitters, facility management firms, and industry fabricators. GV4PEM25B yields exceptional durability and merit for planners in the power engineering industry. This Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic multifunction, Everlink termin and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric are accessible at the finest pricing and lead time through BaltElec online store, a reliable wholesaler aiding consultants in their collection needs.

Clients who have used Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have repeatedly commended the producer's reliability. It has been specified that the remarkable operation of GV4PEM25B - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic multifunction, Everlink termin extends to a spectrum of implementations. Its high-end qualities make it suitable for diverse needs, assuring the success of your industrial, tertiary, and automation ventures.

Our experts commits in catering industrial and tertiary professionals’ needs. We comprehend the customized requirements and preferences of our consumers in the market. By joining forces with BaltElec, our partners access access to the superior costs and availability of high-quality products like GV4PEM25B - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic multifunction, Everlink termin from Schneider Electric at a budget-friendly price. Our registered accounts take advantage of more savings and expedited requests handling.

Seize the moment and procure GV4PEM25B - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic multifunction, Everlink termin at our verified and simple e-commerce site. Don't delay in making this smart action that promises the utmost quality and fulfills the special specifications of vendors like yourselves.

If there are any matters or concerns about GV4PEM25B - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic multifunction, Everlink termin or any other Schneider Electric products, send us a note or refer to our Knowledge base section below. We have collected answers to standard requests for information to facilitate you further in making an informed decision about industrial and tertiary electrical components.

Remember, GV4PEM25B - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic multifunction, Everlink termin from Schneider Electric is consistent, budget-friendly, and exceptional to other brands in the TeSyS Deca GV4 Motor Circuit Breaker category. Feel free to make it a part of your setup instantly. Shop with confidence at Baltelec e-shop, your reliable source for all your professional electrical equipment and automation needs.

In our Baltelec.eu digital store you will discover Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic multifunction, Everlink termin - GV4PEM25B worth 362.87 €, which will be a faithful and current solution for your demands. This commodity is invented by the Schneider Electric brand using the freshest technologies and fulfills the top standards of protection and efficiency. We provide goods from the TeSyS Deca GV4 Motor Circuit Breaker category that integrate longevity and utility, which is an exceptional alternative for various functions. Not minding of whether you crave appliances for small creation or for proficient industrial employment, Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic multifunction, Everlink termin will be a constant partner in your project.

Baltelec strives to make the shopping process as uncomplicated and fast as doable for our users. We offer detailed descriptions and high-quality photos of Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic multifunction, Everlink termin so that you can make an well-informed choice. A team of masters is always ready to help you with any enquiries in the TeSyS Deca GV4 Motor Circuit Breaker section connected to the choosing and use of goods. We are positive that Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic multifunction, Everlink termin will meet your requirements and become an significant element of your gear for just 362.87 €.

Frequently Asked Questions about GV4PEM25B - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic multifunction, Everlink termin:

Recently viewed
GV4PEM25B - Schneider Electric
Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic multifunction, Everlink termin
297,43 € excl. VAT
368,82 € incl. VAT