All categories
Compare Cart

GV4PEM115B - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic multifunction, Everlink terminals - Schneider Electric

Expected in 2-4 weeks
GV4PEM115B - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic multifunction, Everlink terminals - Schneider Electric - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic multifunction, Everlink terminals - Schneider Electric - 0
GV4PEM115B - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic multifunction, Everlink terminals - Schneider Electric
328,55 € excl. VAT
407,40 € incl. VAT
Text About:
Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic multifunction, Everlink terminals - Schneider Electric
407,40 €
SPECIFICATIONS
Main
Device short name GV4PEM
Range TeSys Deca
TeSys Deca
magnetic tripping current 1955 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Thermal-magnetic
Electronic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 37 kW at 400...415 V AC 50/60 Hz
45 kW at 400...415 V AC 50/60 Hz
55 kW at 400...415 V AC 50/60 Hz
45 kW at 500 V AC 50/60 Hz
55 kW at 500 V AC 50/60 Hz
75 kW at 500 V AC 50/60 Hz
75 kW at 660...690 V AC 50/60 Hz
90 kW at 660...690 V AC 50/60 Hz
110 kW at 660...690 V AC 50/60 Hz
Complementary
[in] rated current 115 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
35 kA at 240 V AC 50/60 Hz conforming to UL 60947
18 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
14 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Toggle
Product certifications IEC
UL
CSA
CCC
EAC
ATEX
EU-RO MR
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals EverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² - solid
EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² - flexible
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² - solid
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² - flexible
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.45 kg
Operating position Any position
power dissipation per pole 4.6 W
depth 116 mm
mechanical durability 40000 cycles
electrical durability 10000 cycles for AC-3 at 440 V In/2
5000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards CSA C22.2 No 60947-4-1
UL 60947-4-1
EN/IEC 60947-4-1
EN/IEC 60947-2
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4PEM115B - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic multifunction, Everlink terminals is engineered to meet the wants of professional purchasers, such as switchboard fabricators, electrical fitters, service providers, and original manufacturers. GV4PEM115B offers exceptional efficiency and worth for experts in the power engineering industry. This Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic multifunction, Everlink terminals and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric are on offer at the optimal price and supply period through BaltElec online store, a respected purveyor assisting tradesmen in their buying needs.

Professionals who have used Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have continuously applauded the brand's reliability. It has been stated that the superlative productivity of GV4PEM115B - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic multifunction, Everlink terminals extends to a array of operations. Its first-rate specifications make it perfect choice for wide-ranging specifications, securing success in your industrial, tertiary, and automation endeavors.

Our specialists commits in accommodating industrial and tertiary professionals’ needs. We understand the distinct standards and preferences of our customers in the domain. By teaming up with our specialists, your organization receive access to the leading rates and stock of premium products like GV4PEM115B - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic multifunction, Everlink terminals from Schneider Electric at a competitive price. Baltelec account members take advantage of extra discounts and priority service.

Seize the moment and get GV4PEM115B - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic multifunction, Everlink terminals at our well-established and efficient website. Don't delay in making this prudent selection that ensures the supreme quality and addresses the personalized necessities of customers like your company.

Should there be any uncertainties or concerns about GV4PEM115B - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic multifunction, Everlink terminals or any other Schneider Electric products, drop us a line or refer to our Information center section below. We have amassed answers to routine issues to back you further in making an well-considered decision about industrial and tertiary electrical components.

Remember, GV4PEM115B - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic multifunction, Everlink terminals from Schneider Electric is dependable, cost-effective, and exceptional to opposing companies in the TeSyS Deca GV4 Motor Circuit Breaker category. Feel free to make it a part of your apparatus instantly. Obtain at BaltElec, your esteemed seller for all your Schneider Electric.

In our Baltelec.eu e-commerce store you will encounter Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic multifunction, Everlink terminals - GV4PEM115B worth 400.82 €, which will be a secure and current solution for your desires. This thing is constructed by the Schneider Electric brand using the newest technologies and satisfies the pinnacle standards of assurance and workmanship. We deliver items from the TeSyS Deca GV4 Motor Circuit Breaker category that combine resilience and utility, which is an superior selection for various roles. Regardless of whether you seek hardware for small creation or for proficient industrial utilization, Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic multifunction, Everlink terminals will be a trustworthy aide in your undertaking.

Baltelec ventures to make the acquiring process as effortless and fast as doable for our patrons. We offer detailed explanations and high-quality snapshots of Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic multifunction, Everlink terminals so that you can make an conscious choice. A team of masters is always ready to help you with any queries in the TeSyS Deca GV4 Motor Circuit Breaker section connected to the preferment and use of wares. We are guaranteed that Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic multifunction, Everlink terminals will meet your requirements and become an vital element of your kit for just 400.82 €.

Frequently Asked Questions about GV4PEM115B - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic multifunction, Everlink terminals:

Recently viewed
GV4PEM115B - Schneider Electric
Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic multifunction, Everlink terminals
328,55 € excl. VAT
407,40 € incl. VAT
Expected in 2-4 weeks