GV4PEM03S - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, Everlink term - Schneider Electric

Expected in 2-4 weeks
GV4PEM03S - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, Everlink term - Schneider Electric - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, Everlink term - Schneider Electric - 0
GV4PEM03S - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, Everlink term - Schneider Electric
445,64 € excl. VAT
552,59 € incl. VAT
Text About:
Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, Everlink term - Schneider Electric
552,59 €
SPECIFICATIONS
Main
Device short name GV4PEM
Range TeSys Deca
TeSys Deca
magnetic tripping current 59 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Electronic
Thermal-magnetic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 0.55 kW at 400...415 V AC 50/60 Hz
0.75 kW at 400...415 V AC 50/60 Hz
0.75 kW at 500 V AC 50/60 Hz
1.1 kW at 500 V AC 50/60 Hz
1.1 kW at 660...690 V AC 50/60 Hz
1.5 kW at 660...690 V AC 50/60 Hz
1.5 kW at 500 V AC 50/60 Hz
2.2 kW at 660...690 V AC 50/60 Hz
1.1 kW at 400...415 V AC 50/60 Hz
1.5 kW at 400...415 V AC 50/60 Hz
Complementary
[in] rated current 3.5 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 120 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
18 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
100 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
100 kA at 240 V AC 50/60 Hz conforming to UL 60947
65 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Toggle
Product certifications IEC
UL
CSA
CCC
EAC
ATEX
EU-RO MR
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals EverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² - solid
EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² - flexible
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² - solid
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² - flexible
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.45 kg
Operating position Any position
power dissipation per pole 4.6 W
depth 116 mm
mechanical durability 40000 cycles
electrical durability 40000 cycles for AC-3 at 440 V In/2
40000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards CSA C22.2 No 60947-4-1
UL 60947-4-1
EN/IEC 60947-4-1
EN/IEC 60947-2
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4PEM03S - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, Everlink term is created to meet the expectations of specialized professionals, such as control panel builders, cable technicians, upkeep firms, and industry fabricators. GV4PEM03S furnishes unmatched integrity and merit for experts in the electromechanical industry. This Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, Everlink term and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric are accessible at the unbeatable price and turnaround time through BaltElec website, a distinguished distributor serving tradesmen in their gathering needs.

Engineers who have opted for Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have repeatedly approved the creator's resilience. It has been indicated that the superlative workmanship of GV4PEM03S - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, Everlink term extends to a diverse range of functions. Its top-notch aspects make it ideal solution for different applications. Your developed solution will excel in quality, energy-efficiency and price.

Our team centers in fulfilling industrial and tertiary professionals’ needs. We comprehend the unique expectations and requirements of our consumers in the market. By working with our specialists, your enterprise secure access to the top pricing and supply timeline of superior products like GV4PEM03S - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, Everlink term from Schneider Electric at a reasonable price. Authorized buyers take pleasure in additional savings and expedited requests handling.

Start immediately and obtain GV4PEM03S - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, Everlink term at our well-established and user-friendly platform. Don't delay in making this savvy decision that affirms the top quality and fulfills the special prerequisites of purchasers like your outfit.

In case you have any concerns or concerns about GV4PEM03S - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, Everlink term or any other Schneider Electric products, communicate with us or refer to our Help section section below. We have put together answers to routine requests for information to facilitate you further in making an considered decision about industrial and tertiary electrical components.

Remember, GV4PEM03S - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, Everlink term from Schneider Electric is sure, thrifty, and top-notch to opposing companies in the TeSyS Deca GV4 Motor Circuit Breaker category. Feel free to make it a part of your arrangement instantly. Shop with confidence at BALTELEC, your esteemed seller for all your Schneider Electric.

In our Baltelec.eu web store you will come across Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, Everlink term - GV4PEM03S worth 543.68 €, which will be a reliable and new solution for your necessities. This product is formulated by the Schneider Electric brand using the current technologies and satisfies the leading standards of defense and capability. We present articles from the TeSyS Deca GV4 Motor Circuit Breaker category that combine resilience and functionality, which is an fine election for various operations. In spite of whether you necessitate devices for small production or for experienced industrial application, Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, Everlink term will be a safe adjunct in your task.

Baltelec strives to make the obtaining process as convenient and fast as realizable for our clients. We offer detailed descriptions and high-quality photos of Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, Everlink term so that you can make an enlightened choice. A team of professionals is always ready to help you with any concerns in the TeSyS Deca GV4 Motor Circuit Breaker section related to the nomination and use of goods. We are persuaded that Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, Everlink term will meet your demands and become an imperative element of your machinery for just 543.68 €.

What People Ask about GV4PEM03S - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, Everlink term:

Recently viewed
GV4PEM03S - Schneider Electric
Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, Everlink term
445,64 € excl. VAT
552,59 € incl. VAT
Expected in 2-4 weeks