All categories
Compare Cart

GV4PEM03N6 - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic multifunction, lugs terminals - Schneider Electric

Expected in 2-4 weeks
GV4PEM03N6 - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic multifunction, lugs terminals - Schneider Electric - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic multifunction, lugs terminals - Schneider Electric - 0
GV4PEM03N6 - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic multifunction, lugs terminals - Schneider Electric
298,76 € excl. VAT
370,46 € incl. VAT
Text About:
Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic multifunction, lugs terminals - Schneider Electric
370,46 €
SPECIFICATIONS
Main
Device short name GV4PEM
Range TeSys Deca
TeSys Deca
magnetic tripping current 59 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Electronic
Thermal-magnetic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 0.55 kW at 400...415 V AC 50/60 Hz
0.75 kW at 400...415 V AC 50/60 Hz
0.75 kW at 500 V AC 50/60 Hz
1.1 kW at 500 V AC 50/60 Hz
1.1 kW at 660...690 V AC 50/60 Hz
1.5 kW at 660...690 V AC 50/60 Hz
1.5 kW at 500 V AC 50/60 Hz
2.2 kW at 660...690 V AC 50/60 Hz
1.1 kW at 400...415 V AC 50/60 Hz
1.5 kW at 400...415 V AC 50/60 Hz
Complementary
[in] rated current 3.5 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
65 kA at 240 V AC 50/60 Hz conforming to UL 60947
35 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
18 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Toggle
Product certifications IEC
UL
CSA
CCC
EAC
ATEX
EU-RO MR
Connection pitch 27 mm without spreaders
35 mm with spreaders
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals Lugs-ring terminals
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.45 kg
Operating position Any position
power dissipation per pole 4.6 W
depth 116 mm
mechanical durability 40000 cycles
electrical durability 40000 cycles for AC-3 at 440 V In/2
40000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards CSA C22.2 No 60947-4-1
UL 60947-4-1
EN/IEC 60947-4-1
EN/IEC 60947-2
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4PEM03N6 - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic multifunction, lugs terminals is created to fulfill the requirements of business buyers, such as electrical contractors, cable technicians, maintenance service providers, and primary equipment suppliers. GV4PEM03N6 affords outstanding excellence and benefits for contractors in the automation and control industry. This Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic multifunction, lugs terminals and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric are on offer at the most economical price and shipping time through BALTELEC.EU, a credible dealer supporting professionals in their supply needs.

Technicians who have secured Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have consistently praised the producer's soundness. It has been specified that the unmatched operation of GV4PEM03N6 - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic multifunction, lugs terminals extends to a multitude of implementations. Its ideal specifications make it proper pick to suit a variety of needs, securing success in your industrial, tertiary, and automation endeavors.

Our specialists focuses in accommodating industrial and tertiary professionals’ needs. We appreciate the particular standards and requirements of our stakeholders in the industry. By collaborating with BALTELEC, your company get access to the top price lists and delivery schedule of first-rate products like GV4PEM03N6 - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic multifunction, lugs terminals from Schneider Electric at a budget-friendly price. Our registered accounts appreciate more savings and first-class attention.

Move quickly and obtain GV4PEM03N6 - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic multifunction, lugs terminals at our safe and efficient online portal. Don't delay in making this savvy investment that guarantees the ultimate quality and fulfills the unique requirements of customers like your organization.

When you have any questions or concerns about GV4PEM03N6 - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic multifunction, lugs terminals or any other Schneider Electric products, get in touch with us or refer to our FAQs section below. We have gathered answers to routine doubts to guide you further in making an smart decision about industrial and tertiary electrical components.

Remember, GV4PEM03N6 - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic multifunction, lugs terminals from Schneider Electric is steady, cost-effective, and outstanding to other producers in the TeSyS Deca GV4 Motor Circuit Breaker category. Feel free to make it a part of your inventory now. Snap up at BaltElec, your respected merchant for all your TeSyS Deca GV4 Motor Circuit Breaker.

In our Baltelec.eu web store you will find Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic multifunction, lugs terminals - GV4PEM03N6 worth 364.48 €, which will be a safe and state-of-the-art solution for your desires. This produce is designed by the Schneider Electric brand using the current technologies and obeys the pinnacle standards of defense and productivity. We supply products from the TeSyS Deca GV4 Motor Circuit Breaker category that fuse durability and workability, which is an superior selection for various uses. Without consideration of whether you require machinery for small formation or for proficient industrial exploitation, Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic multifunction, lugs terminals will be a secure helper in your assignment.

Baltelec strives to make the obtaining process as accessible and fast as viable for our customers. We offer detailed narratives and high-quality depictions of Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic multifunction, lugs terminals so that you can make an enlightened choice. A team of connoisseurs is always ready to help you with any matter in the TeSyS Deca GV4 Motor Circuit Breaker section connected to the electing and use of supplies. We are certain that Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic multifunction, lugs terminals will meet your demands and become an needed element of your equipment for just 364.48 €.

Customer Queries about GV4PEM03N6 - Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic multifunction, lugs terminals:

Recently viewed
GV4PEM03N6 - Schneider Electric
Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic multifunction, lugs terminals
298,76 € excl. VAT
370,46 € incl. VAT
Expected in 2-4 weeks