SPECIFICATIONS
Main
Device short name GV4PE
Range TeSys Deca
TeSys Deca
magnetic tripping current 850 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Thermal-magnetic
Electronic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 11 kW at 400...415 V AC 50/60 Hz
15 kW at 500 V AC 50/60 Hz
18.5 kW at 660...690 V AC 50/60 Hz
15 kW at 400...415 V AC 50/60 Hz
18.5 kW at 400...415 V AC 50/60 Hz
22 kW at 400...415 V AC 50/60 Hz
18.5 kW at 500 V AC 50/60 Hz
22 kW at 500 V AC 50/60 Hz
30 kW at 500 V AC 50/60 Hz
22 kW at 660...690 V AC 50/60 Hz
30 kW at 660...690 V AC 50/60 Hz
37 kW at 660...690 V AC 50/60 Hz
45 kW at 660...690 V AC 50/60 Hz
Complementary
[in] rated current 50 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
65 kA at 240 V AC 50/60 Hz conforming to UL 60947
35 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
18 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Toggle
Product certifications IEC
UL
CSA
CCC
EAC
ATEX
EU-RO MR
Connection pitch 27 mm without spreaders
35 mm with spreaders
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals Lugs-ring terminals
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.45 kg
Operating position Any position
power dissipation per pole 4.6 W
depth 116 mm
mechanical durability 40000 cycles
electrical durability 20000 cycles for AC-3 at 440 V In/2
10000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards CSA C22.2 No 60947-4-1
UL 60947-4-1
EN/IEC 60947-4-1
EN/IEC 60947-2
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4PE50N6 - Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, lugs terminals is produced to cover the prerequisites of industry specialists, such as switchboard fabricators, electricians, management services, and manufacturing originators. GV4PE50N6 delivers unmatched durability and beneficence for developers in the control systems industry. This Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, lugs terminals and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric are on offer at the optimal price and supply period through baltelec.eu, a respected provider meeting the needs of industry experts in their obtaining needs.

Patrons who have opted for Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have consistently lauded the brand's resilience. It has been highlighted that the unmatched functionality of GV4PE50N6 - Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, lugs terminals extends to a diverse range of tasks. Its supreme qualities make it suitable for multiple purposes. Your developed solution will excel in quality, energy-efficiency and price.

BALTELEC centers in meeting industrial and tertiary professionals’ needs. We appreciate the distinct standards and demands of our patrons in the market. By partnering with our team, our partners gain access to the leading rates and supply timeline of excellent products like GV4PE50N6 - Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, lugs terminals from Schneider Electric at the lowest price. Authorized buyers enjoy added discounts and premium support.

Start immediately and procure GV4PE50N6 - Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, lugs terminals at our trusted and easy-to-use web store. Don't delay in making this sensible resolution that promises the top quality and complies with the particular criteria of contractors like your organization.

When you have any issues or concerns about GV4PE50N6 - Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, lugs terminals or any other Schneider Electric products, communicate with us or refer to our Information center section below. We have provided answers to frequent queries to advise you further in making an knowledgeable decision about industrial and tertiary electrical components.

Remember, GV4PE50N6 - Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, lugs terminals from Schneider Electric is safe, affordable, and high-quality to its counterparts in the TeSyS Deca GV4 Motor Circuit Breaker category. Don't hesitate to make it a part of your setup today. Order at BaltElec, your dependable vendor for all your professional electrical equipment and automation needs.

In our Baltelec.eu digital store you will encounter Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, lugs terminals - GV4PE50N6 worth 298.21 €, which will be a safe and up-to-date solution for your demands. This product is formulated by the Schneider Electric brand using the freshest technologies and complies with the highest standards of defense and efficacy. We present objects from the TeSyS Deca GV4 Motor Circuit Breaker category that mix longevity and practicality, which is an exceptional selection for various roles. Without consideration of whether you need devices for small generation or for proficient industrial exploitation, Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, lugs terminals will be a constant associate in your task.

Baltelec labors to make the buying process as effortless and fast as attainable for our customers. We offer detailed narratives and high-quality portrayals of Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, lugs terminals so that you can make an knowledgeable choice. A team of masters is always ready to help you with any inquiries in the TeSyS Deca GV4 Motor Circuit Breaker section linked to the electing and use of supplies. We are certain that Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, lugs terminals will meet your expectations and become an essential element of your hardware for just 298.21 €.

FAQ about Schneider Electric Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, lugs terminals:

Recently viewed
GV4PE50N6 - Schneider Electric
Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, lugs terminals
244,43 € excl. VAT
303,09 € incl. VAT
Expected in 2-4 weeks