All categories
Compare Cart

GV4PE25N - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals - Schneider Electric

Expected in 2-4 weeks
GV4PE25N - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals - Schneider Electric - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals - Schneider Electric - 0
GV4PE25N - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals - Schneider Electric
254,94 € excl. VAT
316,13 € incl. VAT
Text About:
Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals - Schneider Electric
316,13 €
SPECIFICATIONS
Main
Device short name GV4PE
Range TeSys Deca
TeSys Deca
magnetic tripping current 425 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Electronic
Thermal-magnetic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 7.5 kW at 660...690 V AC 50/60 Hz
5.5 kW at 400...415 V AC 50/60 Hz
7.5 kW at 500 V AC 50/60 Hz
9 kW at 660...690 V AC 50/60 Hz
11 kW at 660...690 V AC 50/60 Hz
7.5 kW at 400...415 V AC 50/60 Hz
9 kW at 400...415 V AC 50/60 Hz
11 kW at 400...415 V AC 50/60 Hz
9 kW at 500 V AC 50/60 Hz
11 kW at 500 V AC 50/60 Hz
15 kW at 500 V AC 50/60 Hz
15 kW at 660...690 V AC 50/60 Hz
18.5 kW at 660...690 V AC 50/60 Hz
Complementary
[in] rated current 25 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
65 kA at 240 V AC 50/60 Hz conforming to UL 60947
35 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
18 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Toggle
Product certifications IEC
UL
CSA
CCC
EAC
ATEX
EU-RO MR
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals EverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² - solid
EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² - flexible
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² - solid
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² - flexible
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.45 kg
Operating position Any position
power dissipation per pole 4.6 W
depth 116 mm
mechanical durability 40000 cycles
electrical durability 40000 cycles for AC-3 at 440 V In/2
20000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards CSA C22.2 No 60947-4-1
UL 60947-4-1
EN/IEC 60947-4-1
EN/IEC 60947-2
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4PE25N - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals is engineered to address the wants of professional buyers, such as electrical contractors, electrical fitters, facility management firms, and industry fabricators. GV4PE25N furnishes excellent standards and asset for consultants in the electrical engineering industry. This Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric can be purchased at the most economical price and lead time through baltelec.eu, a well-known purveyor supporting technicians in their provision needs.

Buyers who have chosen Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have invariably extolled the maker's durability. It has been stated that the extraordinary productivity of GV4PE25N - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals extends to a wide range of operations. Its first-rate qualities make it perfect choice for multiple purposes, guaranteeing the success of your industrial, tertiary, and automation contracts.

Our professionals dedicates in providing for industrial and tertiary professionals’ needs. We know the individual demands and standards of our partners in the niche. By working with us, your team access access to the finest charges and lead time of premium products like GV4PE25N - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals from Schneider Electric at an attractive price. Authorized buyers get added discounts and expedited requests handling.

Take action and order GV4PE25N - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals at our reliable and simple virtual storefront. Don't delay in making this shrewd investment that guarantees the top quality and meets the unique needs of professionals like your firm.

If you possess any uncertainties or concerns about GV4PE25N - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals or any other Schneider Electric products, email us or refer to our Common Questions section below. We have put together answers to typical issues to serve you further in making an informed decision about industrial and tertiary electrical components.

Remember, GV4PE25N - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals from Schneider Electric is secure, budget-friendly, and first-rate to other manufacturers in the TeSyS Deca GV4 Motor Circuit Breaker category. Make it a part of your inventory right now. Order at baltele.eu, your faithful dealer for all your TeSyS Deca GV4 Motor Circuit Breaker.

In our Baltelec.eu online store you will encounter Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals - GV4PE25N worth 311.03 €, which will be a trustworthy and contemporary solution for your requirements. This product is invented by the Schneider Electric brand using the state-of-the-art technologies and aligns with the peak standards of safety and capacity. We deliver articles from the TeSyS Deca GV4 Motor Circuit Breaker category that integrate toughness and usability, which is an excellent choice for various objectives. In spite of whether you desire hardware for small generation or for skilled industrial utilization, Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals will be a safe helper in your duty.

Baltelec efforts to make the attaining process as convenient and fast as achievable for our purchasers. We offer detailed narratives and high-quality photos of Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals so that you can make an advised choice. A team of maestros is always ready to help you with any queries in the TeSyS Deca GV4 Motor Circuit Breaker section linked to the picking and use of wares. We are trusting that Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals will meet your anticipations and become an important element of your inventory for just 311.03 €.

What People Ask about Schneider Electric Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals:

Recently viewed
GV4PE25N - Schneider Electric
Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals
254,94 € excl. VAT
316,13 € incl. VAT
Expected in 2-4 weeks