SPECIFICATIONS
Main
Device short name GV4PE
Range TeSys Deca
TeSys Deca
magnetic tripping current 1955 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Thermal-magnetic
Electronic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 37 kW at 400...415 V AC 50/60 Hz
45 kW at 400...415 V AC 50/60 Hz
55 kW at 400...415 V AC 50/60 Hz
45 kW at 500 V AC 50/60 Hz
55 kW at 500 V AC 50/60 Hz
75 kW at 500 V AC 50/60 Hz
75 kW at 660...690 V AC 50/60 Hz
90 kW at 660...690 V AC 50/60 Hz
110 kW at 660...690 V AC 50/60 Hz
Complementary
[in] rated current 115 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 120 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
18 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
100 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
100 kA at 240 V AC 50/60 Hz conforming to UL 60947
65 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Toggle
Product certifications IEC
UL
CSA
CCC
EAC
ATEX
EU-RO MR
Connection pitch 27 mm without spreaders
35 mm with spreaders
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals Lugs-ring terminals
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.45 kg
Operating position Any position
power dissipation per pole 4.6 W
depth 116 mm
mechanical durability 40000 cycles
electrical durability 10000 cycles for AC-3 at 440 V In/2
5000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards CSA C22.2 No 60947-4-1
UL 60947-4-1
EN/IEC 60947-4-1
EN/IEC 60947-2
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4PE115S6 - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 100kA, thermal magnetic, lugs terminals is designed to respond to the demands of industry specialists, such as installers, electrical fitters, management services, and primary equipment makers. GV4PE115S6 dispenses superb standards and benefits for developers in the electromechanical industry. This Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 100kA, thermal magnetic, lugs terminals and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric can be acquired at the optimal price and shipping time through BALTELEC website, a respected dealer catering to specialists in their provision needs.

Contractors who have secured Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have persistently admired the brand's trustworthiness. It has been highlighted that the remarkable operation of GV4PE115S6 - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 100kA, thermal magnetic, lugs terminals extends to a diverse range of use. Its premium properties make it fitting to meet diverse demands, promoting success in your industrial, tertiary, and automation efforts.

Our experts specializes in meeting industrial and tertiary professionals’ needs. We appreciate the distinct standards and demands of our clients in the field. By teaming up with Baltelec team, you secure access to the optimal charges and lead time of first-rate products like GV4PE115S6 - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 100kA, thermal magnetic, lugs terminals from Schneider Electric at a reasonable price. Registered users get further discounts and exclusive assistance.

Move quickly and order GV4PE115S6 - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 100kA, thermal magnetic, lugs terminals at our risk-free and accessible online store. Don't delay in making this clever resolution that ensures the utmost quality and meets the specific requests of clients like your organization.

In the event of any worries or concerns about GV4PE115S6 - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 100kA, thermal magnetic, lugs terminals or any other Schneider Electric products, drop us a line or refer to our Information center section below. We have brought together answers to regular concerns to guide you further in making an well-considered decision about industrial and tertiary electrical components.

Remember, GV4PE115S6 - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 100kA, thermal magnetic, lugs terminals from Schneider Electric is trustworthy, inexpensive, and exceptional to other brands in the TeSyS Deca GV4 Motor Circuit Breaker category. Make it a part of your solution this moment. Snap up at baltele.eu, your reliable source for all your TeSyS Deca GV4 Motor Circuit Breaker.

In our Baltelec.eu web store you will find Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 100kA, thermal magnetic, lugs terminals - GV4PE115S6 worth 452.10 €, which will be a constant and fashionable solution for your needs. This merchandise is developed by the Schneider Electric brand using the state-of-the-art technologies and complies with the peak standards of reliability and workmanship. We give objects from the TeSyS Deca GV4 Motor Circuit Breaker category that combine endurance and usefulness, which is an first-rate possibility for various tasks. Notwithstanding of whether you desire gear for small generation or for specialized industrial employment, Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 100kA, thermal magnetic, lugs terminals will be a secure companion in your job.

Baltelec works to make the procuring process as effortless and fast as realizable for our patrons. We offer detailed explanations and high-quality depictions of Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 100kA, thermal magnetic, lugs terminals so that you can make an well-informed choice. A team of professionals is always ready to help you with any wonder in the TeSyS Deca GV4 Motor Circuit Breaker section pertaining to the deciding and use of equipment. We are convinced that Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 100kA, thermal magnetic, lugs terminals will meet your expectations and become an significant element of your hardware for just 452.10 €.