All categories
Compare Cart

GV4PE07S6 - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 100kA, thermal magnetic, lugs terminals - Schneider Electric

Expected in 2-4 weeks
GV4PE07S6 - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 100kA, thermal magnetic, lugs terminals - Schneider Electric - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 100kA, thermal magnetic, lugs terminals - Schneider Electric - 0
GV4PE07S6 - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 100kA, thermal magnetic, lugs terminals - Schneider Electric
287,35 € excl. VAT
356,32 € incl. VAT
Text About:
Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 100kA, thermal magnetic, lugs terminals - Schneider Electric
356,32 €
SPECIFICATIONS
Main
Device short name GV4PE
Range TeSys Deca
TeSys Deca
magnetic tripping current 119 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Electronic
Thermal-magnetic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 1.5 kW at 400...415 V AC 50/60 Hz
2.2 kW at 400...415 V AC 50/60 Hz
2.5 kW at 400...415 V AC 50/60 Hz
3 kW at 400...415 V AC 50/60 Hz
2.2 kW at 500 V AC 50/60 Hz
2.5 kW at 500 V AC 50/60 Hz
3 kW at 500 V AC 50/60 Hz
4 kW at 500 V AC 50/60 Hz
3 kW at 660...690 V AC 50/60 Hz
4 kW at 660...690 V AC 50/60 Hz
5.5 kW at 660...690 V AC 50/60 Hz
7.5 kW at 660...690 V AC 50/60 Hz
Complementary
[in] rated current 7 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 120 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
18 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
100 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
100 kA at 240 V AC 50/60 Hz conforming to UL 60947
65 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Toggle
Product certifications IEC
UL
CSA
CCC
EAC
ATEX
EU-RO MR
Connection pitch 27 mm without spreaders
35 mm with spreaders
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals Lugs-ring terminals
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.45 kg
Operating position Any position
power dissipation per pole 4.6 W
depth 116 mm
mechanical durability 40000 cycles
electrical durability 40000 cycles for AC-3 at 440 V In/2
40000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards CSA C22.2 No 60947-4-1
UL 60947-4-1
EN/IEC 60947-4-1
EN/IEC 60947-2
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4PE07S6 - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 100kA, thermal magnetic, lugs terminals is fashioned to cover the prerequisites of professional buyers, such as installers, electrical technicians, upkeep firms, and primary equipment makers. GV4PE07S6 affords superior quality and gain for experts in the energy management industry. This Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 100kA, thermal magnetic, lugs terminals and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric are on offer at the lowest cost and procurement time through BaltElec online store, a dependable purveyor meeting the needs of engineers in their supply needs.

Professionals who have bought Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have persistently admired the creator's resilience. It has been remarked that the notable energy-efficiency of GV4PE07S6 - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 100kA, thermal magnetic, lugs terminals extends to a multitude of scenarios. Its top-notch specifications make it great selection to satisfy a wide array of needs, securing success in your industrial, tertiary, and automation endeavors.

BaltElec team focuses in serving industrial and tertiary professionals’ needs. We understand the specific standards and standards of our patrons in the market. By working with BaltElec, you get access to the top price lists and availability of high-quality products like GV4PE07S6 - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 100kA, thermal magnetic, lugs terminals from Schneider Electric at a budget-friendly price. Professional buyers with Baltelec account get special savings and premium support.

Start immediately and acquire GV4PE07S6 - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 100kA, thermal magnetic, lugs terminals at our certified and accessible online portal. Don't delay in making this clever pick that validates the highest quality and achieves the targeted prerequisites of purchasers like your organization.

If you encounter any concerns or concerns about GV4PE07S6 - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 100kA, thermal magnetic, lugs terminals or any other Schneider Electric products, email us or refer to our Frequently Asked Queries section below. We have put together answers to habitual uncertainties to advise you further in making an well-considered decision about industrial and tertiary electrical components.

Remember, GV4PE07S6 - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 100kA, thermal magnetic, lugs terminals from Schneider Electric is consistent, economical, and high-quality to market challengers in the TeSyS Deca GV4 Motor Circuit Breaker category. Make it a part of your solution without delay. Get at Baltelec e-shop, your esteemed seller for all your TeSyS Deca GV4 Motor Circuit Breaker.

In our Baltelec.eu dot-com store you will encounter Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 100kA, thermal magnetic, lugs terminals - GV4PE07S6 worth 350.57 €, which will be a steadfast and cutting-edge solution for your necessities. This article is formulated by the Schneider Electric brand using the freshest technologies and complies with the optimal standards of safety and effectiveness. We propose produce from the TeSyS Deca GV4 Motor Circuit Breaker category that mix lastingness and usefulness, which is an excellent alternative for various uses. Despite of whether you crave appliances for small fabrication or for professional industrial utilization, Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 100kA, thermal magnetic, lugs terminals will be a secure helper in your work.

Baltelec efforts to make the shopping process as manageable and fast as accomplishable for our clients. We offer detailed explanations and high-quality images of Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 100kA, thermal magnetic, lugs terminals so that you can make an knowledgeable choice. A team of connoisseurs is always ready to help you with any enquiries in the TeSyS Deca GV4 Motor Circuit Breaker section involved to the deciding and use of materials. We are guaranteed that Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 100kA, thermal magnetic, lugs terminals will meet your demands and become an needed element of your hardware for just 350.57 €.

Popular Questions about Schneider Electric Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 100kA, thermal magnetic, lugs terminals:

Recently viewed
GV4PE07S6 - Schneider Electric
Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 100kA, thermal magnetic, lugs terminals
287,35 € excl. VAT
356,32 € incl. VAT
Expected in 2-4 weeks