SPECIFICATIONS
Main
Device short name GV4PE
Range TeSys Deca
TeSys Deca
magnetic tripping current 34 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Thermal-magnetic
Electronic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 0.25 kW at 400...415 V AC 50/60 Hz
0.37 kW at 400...415 V AC 50/60 Hz
0.55 kW at 400...415 V AC 50/60 Hz
0.75 kW at 400...415 V AC 50/60 Hz
0.37 kW at 500 V AC 50/60 Hz
0.55 kW at 500 V AC 50/60 Hz
0.75 kW at 500 V AC 50/60 Hz
1.1 kW at 500 V AC 50/60 Hz
0.55 kW at 660...690 V AC 50/60 Hz
0.75 kW at 660...690 V AC 50/60 Hz
1.1 kW at 660...690 V AC 50/60 Hz
1.5 kW at 660...690 V AC 50/60 Hz
Complementary
[in] rated current 2 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
65 kA at 240 V AC 50/60 Hz conforming to UL 60947
35 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
18 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Toggle
Product certifications IEC
UL
CSA
CCC
EAC
ATEX
EU-RO MR
Connection pitch 27 mm without spreaders
35 mm with spreaders
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals Lugs-ring terminals
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.45 kg
Operating position Any position
power dissipation per pole 4.6 W
depth 116 mm
mechanical durability 40000 cycles
electrical durability 40000 cycles for AC-3 at 440 V In/2
40000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards CSA C22.2 No 60947-4-1
UL 60947-4-1
EN/IEC 60947-4-1
EN/IEC 60947-2
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4PE02N6 - Motor circuit breaker, TeSys GV4, 3P, 2A, Icu 50kA, thermal magnetic, lugs terminals is conceived to meet the wants of trade buyers, such as electrical installers, electrical fitters, upkeep firms, and Industry suppliers. GV4PE02N6 furnishes unmatched capability and asset for developers in the power management industry. This Motor circuit breaker, TeSys GV4, 3P, 2A, Icu 50kA, thermal magnetic, lugs terminals and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric are available at the lowest cost and fulfillment period through BaltElec website, a well-regarded supplier attending to professionals in their acquisition needs.

Patrons who have opted for Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have regularly applauded the creator's robustness. It has been stated that the superior efficiency of GV4PE02N6 - Motor circuit breaker, TeSys GV4, 3P, 2A, Icu 50kA, thermal magnetic, lugs terminals extends to a spectrum of implementations. Its exceptional features make it optimal for diverse needs. Your developed solution will excel in quality, energy-efficiency and price.

Our experts commits in addressing industrial and tertiary professionals’ needs. We get the distinct needs and desires of our stakeholders in the industry. By joining forces with our professionals, our partners access access to the premier pricing and lead time of the top-of-the-line products like GV4PE02N6 - Motor circuit breaker, TeSys GV4, 3P, 2A, Icu 50kA, thermal magnetic, lugs terminals from Schneider Electric at an attractive price. Professional buyers with Baltelec account take pleasure in additional savings and priority service.

Act now and procure GV4PE02N6 - Motor circuit breaker, TeSys GV4, 3P, 2A, Icu 50kA, thermal magnetic, lugs terminals at our dependable and intuitive platform. Don't delay in making this prudent move that affirms the highest quality and covers the customized criteria of contractors like you.

When you have any concerns or concerns about GV4PE02N6 - Motor circuit breaker, TeSys GV4, 3P, 2A, Icu 50kA, thermal magnetic, lugs terminals or any other Schneider Electric products, communicate with us or refer to our Support section section below. We have compiled answers to routine queries to benefit you further in making an considered decision about industrial and tertiary electrical components.

Remember, GV4PE02N6 - Motor circuit breaker, TeSys GV4, 3P, 2A, Icu 50kA, thermal magnetic, lugs terminals from Schneider Electric is credible, budget-friendly, and exceptional to other producers in the TeSyS Deca GV4 Motor Circuit Breaker category. Don't hesitate to make it a part of your apparatus without delay. Shop with confidence at baltele.eu, your faithful dealer for all your professional electrical equipment and automation needs.

In our Baltelec.eu virtual store you will locate Motor circuit breaker, TeSys GV4, 3P, 2A, Icu 50kA, thermal magnetic, lugs terminals - GV4PE02N6 worth 291.77 €, which will be a constant and cutting-edge solution for your preferences. This goods is constructed by the Schneider Electric brand using the advanced technologies and conforms to the premier standards of protection and efficiency. We deliver objects from the TeSyS Deca GV4 Motor Circuit Breaker category that blend resilience and usefulness, which is an top-notch option for various roles. In defiance of whether you necessitate appliances for small output or for qualified industrial purpose, Motor circuit breaker, TeSys GV4, 3P, 2A, Icu 50kA, thermal magnetic, lugs terminals will be a constant partner in your duty.

Baltelec attempts to make the securing process as smooth and fast as doable for our customers. We offer detailed accounts and high-quality portrayals of Motor circuit breaker, TeSys GV4, 3P, 2A, Icu 50kA, thermal magnetic, lugs terminals so that you can make an conscious choice. A team of experts is always ready to help you with any doubts in the TeSyS Deca GV4 Motor Circuit Breaker section referencing to the electing and use of equipment. We are confident that Motor circuit breaker, TeSys GV4, 3P, 2A, Icu 50kA, thermal magnetic, lugs terminals will meet your needs and become an indispensable element of your machinery for just 291.77 €.

FAQ about GV4PE02N6 - Motor circuit breaker, TeSys GV4, 3P, 2A, Icu 50kA, thermal magnetic, lugs terminals:

Recently viewed
GV4PE02N6 - Schneider Electric
Motor circuit breaker, TeSys GV4, 3P, 2A, Icu 50kA, thermal magnetic, lugs terminals
239,16 € excl. VAT
296,55 € incl. VAT
Expected in 2-4 weeks