SPECIFICATIONS
Main
Device short name GV4P
Range TeSys Deca
TeSys Deca
magnetic tripping current 850 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Thermal-magnetic
Electronic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 11 kW at 400...415 V AC 50/60 Hz
15 kW at 500 V AC 50/60 Hz
18.5 kW at 660...690 V AC 50/60 Hz
15 kW at 400...415 V AC 50/60 Hz
18.5 kW at 400...415 V AC 50/60 Hz
22 kW at 400...415 V AC 50/60 Hz
18.5 kW at 500 V AC 50/60 Hz
22 kW at 500 V AC 50/60 Hz
30 kW at 500 V AC 50/60 Hz
22 kW at 660...690 V AC 50/60 Hz
30 kW at 660...690 V AC 50/60 Hz
37 kW at 660...690 V AC 50/60 Hz
45 kW at 660...690 V AC 50/60 Hz
Complementary
[in] rated current 50 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
35 kA at 240 V AC 50/60 Hz conforming to UL 60947
18 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
14 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Rotary handle
Product certifications IEC
UL
CSA
CCC
EAC
ATEX
EU-RO MR
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals EverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² - solid
EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² - flexible
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² - solid
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² - flexible
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.6 kg
Operating position Any position
power dissipation per pole 4.6 W
depth 165 mm
mechanical durability 40000 cycles
electrical durability 20000 cycles for AC-3 at 440 V In/2
10000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards CSA C22.2 No 60947-4-1
UL 60947-4-1
EN/IEC 60947-4-1
EN/IEC 60947-2
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4P50B - Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 25kA, thermal magnetic, Everlink terminals is crafted to address the obligations of professional buyers, such as installers, electricians, support service firms, and primary equipment makers. GV4P50B supplies outstanding quality and merit for technicians in the power management industry. This Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 25kA, thermal magnetic, Everlink terminals and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric are procurable at the most favorable cost and lead time through BaltElec website, a trustworthy provider attending to professionals in their provision needs.

Patrons who have used Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have repeatedly admired the maker's dependability. It has been pointed out that the remarkable capability of GV4P50B - Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 25kA, thermal magnetic, Everlink terminals extends to a broad spectrum of utilizations. Its supreme traits make it great selection for multiple purposes, promoting success in your industrial, tertiary, and automation efforts.

BaltElec team dedicates in meeting industrial and tertiary professionals’ needs. We recognize the customized needs and requirements of our customers in the domain. By joining forces with our professionals, your team get access to the optimal rates and lead time of superior products like GV4P50B - Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 25kA, thermal magnetic, Everlink terminals from Schneider Electric at the lowest price. Baltelec account members appreciate further discounts and dedicated support.

Start immediately and order GV4P50B - Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 25kA, thermal magnetic, Everlink terminals at our secure and easy-to-use online store. Don't delay in making this wise move that certifies the utmost quality and caters to the distinct specifications of buyers like your team.

In case you have any inquiries or concerns about GV4P50B - Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 25kA, thermal magnetic, Everlink terminals or any other Schneider Electric products, email us or refer to our Frequently Asked Questions section below. We have consolidated answers to usual concerns to back you further in making an smart decision about industrial and tertiary electrical components.

Remember, GV4P50B - Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 25kA, thermal magnetic, Everlink terminals from Schneider Electric is secure, cost-effective, and high-quality to its rivals in the TeSyS Deca GV4 Motor Circuit Breaker category. Don't hesitate to make it a part of your installation this moment. Buy at Baltelec webstore, your preferred supplier for all your TeSyS Deca GV4 Motor Circuit Breaker.

In our Baltelec.eu web store you will encounter Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 25kA, thermal magnetic, Everlink terminals - GV4P50B worth 269.36 €, which will be a faithful and modern solution for your desires. This commodity is engineered by the Schneider Electric brand using the freshest technologies and fulfills the pinnacle standards of precaution and capacity. We propose products from the TeSyS Deca GV4 Motor Circuit Breaker category that fuse toughness and operability, which is an top-notch possibility for various uses. Irrespective of whether you desire tools for small generation or for skilled industrial application, Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 25kA, thermal magnetic, Everlink terminals will be a safe facilitator in your work.

Baltelec labors to make the acquiring process as accessible and fast as accomplishable for our users. We offer detailed descriptions and high-quality snapshots of Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 25kA, thermal magnetic, Everlink terminals so that you can make an informed choice. A team of masters is always ready to help you with any queries in the TeSyS Deca GV4 Motor Circuit Breaker section associated to the opting and use of goods. We are assured that Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 25kA, thermal magnetic, Everlink terminals will meet your requirements and become an vital element of your equipment for just 269.36 €.

Common Questions about Schneider Electric GV4P50B:

Recently viewed
GV4P50B - Schneider Electric
Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 25kA, thermal magnetic, Everlink terminals
220,79 € excl. VAT
273,78 € incl. VAT
Expected in 2-4 weeks