Main
Device short name GV4P
Range TeSys Deca
TeSys Deca
magnetic tripping current 425 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Electronic
Thermal-magnetic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 7.5 kW at 660...690 V AC 50/60 Hz
5.5 kW at 400...415 V AC 50/60 Hz
7.5 kW at 500 V AC 50/60 Hz
9 kW at 660...690 V AC 50/60 Hz
11 kW at 660...690 V AC 50/60 Hz
7.5 kW at 400...415 V AC 50/60 Hz
9 kW at 400...415 V AC 50/60 Hz
11 kW at 400...415 V AC 50/60 Hz
9 kW at 500 V AC 50/60 Hz
11 kW at 500 V AC 50/60 Hz
15 kW at 500 V AC 50/60 Hz
15 kW at 660...690 V AC 50/60 Hz
18.5 kW at 660...690 V AC 50/60 Hz
Complementary
[in] rated current 25 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
65 kA at 240 V AC 50/60 Hz conforming to UL 60947
35 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
18 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Rotary handle
Product certifications IEC
UL
CSA
CCC
EAC
ATEX
EU-RO MR
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals EverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² - solid
EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² - flexible
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² - solid
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² - flexible
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.6 kg
Operating position Any position
power dissipation per pole 4.6 W
depth 165 mm
mechanical durability 40000 cycles
electrical durability 40000 cycles for AC-3 at 440 V In/2
20000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards CSA C22.2 No 60947-4-1
UL 60947-4-1
EN/IEC 60947-4-1
EN/IEC 60947-2
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4P25N - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals is formulated to address the obligations of specialized professionals, such as panel manufacturers, cable technicians, upkeep firms, and Industry suppliers. GV4P25N dispenses excellent robustness and value for contractors in the energy management industry. This Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric can be obtained the best price and distribution time through BALTELEC.EU, a dependable purveyor helping tradesmen in their gathering needs.

Clients who have purchased Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have commonly lauded the brand's resilience. It has been remarked that the extraordinary performance of GV4P25N - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals extends to a spectrum of deployments. Its premium attributes make it perfect choice to satisfy a wide array of needs, securing success in your industrial, tertiary, and automation endeavors.

Our experts dedicates in meeting industrial and tertiary professionals’ needs. We comprehend the specific criteria and expectations of our buyers in the niche. By teaming up with Baltelec team, your company secure access to the superior price and supply timeline of first-rate products like GV4P25N - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals from Schneider Electric at the most competitive price. Baltelec account members get additional savings and preferred assistance.

Don't wait and buy GV4P25N - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals at our trusted and convenient e-commerce site. Don't delay in making this intelligent resolution that secures the paramount quality and covers the specific expectations of vendors like yourselves.

If there are any inquiries or concerns about GV4P25N - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals or any other Schneider Electric products, connect with us or refer to our Information center section below. We have curated answers to standard problems to support you further in making an thoughtful decision about industrial and tertiary electrical components.

Remember, GV4P25N - Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals from Schneider Electric is reliable, inexpensive, and elite to alternative suppliers in the TeSyS Deca GV4 Motor Circuit Breaker category. Don't hesitate to make it a part of your apparatus without delay. Buy at Baltelec e-shop, your faithful dealer for all your professional electrical equipment and automation needs.

In our Baltelec.eu electronic store you will find Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals - GV4P25N worth 329.19 €, which will be a steadfast and new solution for your wishes. This product is produced by the Schneider Electric brand using the modern technologies and adheres to the highest standards of reliability and effectiveness. We propose products from the TeSyS Deca GV4 Motor Circuit Breaker category that blend sturdiness and workability, which is an superb election for various uses. Independent of whether you need equipment for small assembly or for specialized industrial operation, Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals will be a sure aide in your undertaking.

Baltelec ventures to make the securing process as manageable and fast as possible for our users. We offer detailed summaries and high-quality snapshots of Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals so that you can make an advised choice. A team of specialists is always ready to help you with any inquiries in the TeSyS Deca GV4 Motor Circuit Breaker section involved to the opting and use of commodities. We are convinced that Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals will meet your needs and become an significant element of your equipment for just 329.19 €.

FAQ about GV4P25N:

Recently viewed
GV4P25N - Schneider Electric
Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals
269,83 € excl. VAT
334,59 € incl. VAT
Expected in 2-4 weeks