SPECIFICATIONS
Main
Device short name GV4P
Range TeSys Deca
TeSys Deca
magnetic tripping current 1955 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Electronic
Thermal-magnetic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 37 kW at 400...415 V AC 50/60 Hz
45 kW at 400...415 V AC 50/60 Hz
55 kW at 400...415 V AC 50/60 Hz
45 kW at 500 V AC 50/60 Hz
55 kW at 500 V AC 50/60 Hz
75 kW at 500 V AC 50/60 Hz
75 kW at 660...690 V AC 50/60 Hz
90 kW at 660...690 V AC 50/60 Hz
110 kW at 660...690 V AC 50/60 Hz
Complementary
[in] rated current 115 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
35 kA at 240 V AC 50/60 Hz conforming to UL 60947
18 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
14 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Rotary handle
Product certifications IEC
UL
CSA
CCC
EAC
ATEX
EU-RO MR
Connection pitch 27 mm without spreaders
35 mm with spreaders
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals Lugs-ring terminals
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.6 kg
Operating position Any position
power dissipation per pole 4.6 W
depth 165 mm
mechanical durability 40000 cycles
electrical durability 10000 cycles for AC-3 at 440 V In/2
5000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards CSA C22.2 No 60947-4-1
UL 60947-4-1
EN/IEC 60947-4-1
EN/IEC 60947-2
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4P115B6 - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, lugs terminals is conceived to meet the desires of sector experts, such as electrical installers, electricians, maintenance companies, and equipment creators. GV4P115B6 supplies outstanding durability and asset for planners in the power systems industry. This Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, lugs terminals and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric can be ordered at the optimal price and turnaround time through BALTELEC website, an independent purveyor attending to engineers in their buying needs.

Contractors who have acquired Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have frequently praised the manufacturer’s dependability. It has been remarked that the superlative effectiveness of GV4P115B6 - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, lugs terminals extends to a extensive scope of operations. Its first-rate characteristics make it fitting to satisfy a wide array of needs, guaranteeing the success of your industrial, tertiary, and automation contracts.

Our team dedicates in meeting industrial and tertiary professionals’ needs. We recognize the specific expectations and expectations of our stakeholders in the domain. By working with BaltElec, your team access access to the optimal fees and inventory of high-quality products like GV4P115B6 - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, lugs terminals from Schneider Electric at an economical price. Our registered accounts benefit from further discounts and top-tier service.

Seize the moment and grab GV4P115B6 - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, lugs terminals at our dependable and accessible website. Don't delay in making this astute plan that assures the greatest quality and fulfills the defined demands of suppliers like your group.

If there are any worries or concerns about GV4P115B6 - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, lugs terminals or any other Schneider Electric products, message us or refer to our Information center section below. We have brought together answers to standard queries to guide you further in making an knowledgeable decision about industrial and tertiary electrical components.

Remember, GV4P115B6 - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, lugs terminals from Schneider Electric is credible, affordable, and exceptional to other vendors in the TeSyS Deca GV4 Motor Circuit Breaker category. Make it a part of your electrical system immediately. Obtain at BALTELEC, your reliable retailer for all your TeSyS Deca GV4 Motor Circuit Breaker.

In our Baltelec.eu internet store you will identify Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, lugs terminals - GV4P115B6 worth 320.65 €, which will be a trustworthy and modern solution for your demands. This commodity is engineered by the Schneider Electric brand using the modern technologies and aligns with the maximum standards of security and performance. We deliver produce from the TeSyS Deca GV4 Motor Circuit Breaker category that blend durability and efficacy, which is an superb alternative for various functions. In defiance of whether you want gear for small production or for experienced industrial implementation, Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, lugs terminals will be a safe assistant in your endeavor.

Baltelec efforts to make the procuring process as convenient and fast as viable for our clients. We offer detailed descriptions and high-quality photographs of Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, lugs terminals so that you can make an advised choice. A team of professionals is always ready to help you with any matter in the TeSyS Deca GV4 Motor Circuit Breaker section associated to the preferment and use of goods. We are affirmed that Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, lugs terminals will meet your demands and become an essential element of your equipment for just 320.65 €.

Frequently Raised Questions about GV4P115B6 - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, lugs terminals:

Recently viewed
GV4P115B6 - Schneider Electric
Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, lugs terminals
262,83 € excl. VAT
325,91 € incl. VAT
Expected in 2-4 weeks