All categories
Compare Cart

GV4P115B - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals - Schneider Electric

Expected in 2-4 weeks
GV4P115B - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals - Schneider Electric - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals - Schneider Electric - 0
GV4P115B - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals - Schneider Electric
278,60 € excl. VAT
345,46 € incl. VAT
Text About:
Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals - Schneider Electric
345,46 €
SPECIFICATIONS
Main
Device short name GV4P
Range TeSys Deca
TeSys Deca
magnetic tripping current 1955 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Thermal-magnetic
Electronic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 37 kW at 400...415 V AC 50/60 Hz
45 kW at 400...415 V AC 50/60 Hz
55 kW at 400...415 V AC 50/60 Hz
45 kW at 500 V AC 50/60 Hz
55 kW at 500 V AC 50/60 Hz
75 kW at 500 V AC 50/60 Hz
75 kW at 660...690 V AC 50/60 Hz
90 kW at 660...690 V AC 50/60 Hz
110 kW at 660...690 V AC 50/60 Hz
Complementary
[in] rated current 115 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
35 kA at 240 V AC 50/60 Hz conforming to UL 60947
18 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
14 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Rotary handle
Product certifications IEC
UL
CSA
CCC
EAC
ATEX
EU-RO MR
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals EverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² - solid
EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² - flexible
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² - solid
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² - flexible
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.6 kg
Operating position Any position
power dissipation per pole 4.6 W
depth 165 mm
mechanical durability 40000 cycles
electrical durability 10000 cycles for AC-3 at 440 V In/2
5000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards CSA C22.2 No 60947-4-1
UL 60947-4-1
EN/IEC 60947-4-1
EN/IEC 60947-2
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4P115B - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals is conceived to satisfy the demands of professional buyers, such as panel manufacturers, electric engineers, repair companies, and original producers. GV4P115B offers first-rate reliability and value for experts in the power systems industry. This Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric are accessible at the most affordable rate and delivery period through BaltElec online store, an independent reseller meeting the needs of professionals in their purchasing needs.

Clients who have adopted Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have habitually praised the brand's sturdiness. It has been emphasized that the outstanding effectiveness of GV4P115B - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals extends to a broad spectrum of applications. Its ideal attributes make it appropriate for wide-ranging specifications, securing success in your industrial, tertiary, and automation endeavors.

BALTELEC centers in accommodating industrial and tertiary professionals’ needs. We appreciate the unique expectations and anticipations of our patrons in the industry. By collaborating with BaltElec, your enterprise acquire access to the optimal price and stock of the top-of-the-line products like GV4P115B - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals from Schneider Electric at a competitive price. Baltelec account members receive special savings and priority service.

Start immediately and buy GV4P115B - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals at our safe and accessible webshop. Don't delay in making this wise action that ensures the paramount quality and satisfies the distinct requirements of professionals like you.

If you possess any worries or concerns about GV4P115B - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals or any other Schneider Electric products, send us a note or refer to our Frequently Asked Questions section below. We have compiled answers to standard problems to serve you further in making an educated decision about industrial and tertiary electrical components.

Remember, GV4P115B - Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals from Schneider Electric is dependable, budget-friendly, and exceptional to other vendors in the TeSyS Deca GV4 Motor Circuit Breaker category. Make it a part of your configuration today. Get at BALTELEC, your reliable retailer for all your TeSyS Deca GV4 Motor Circuit Breaker.

In our Baltelec.eu e-commerce store you will locate Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals - GV4P115B worth 339.89 €, which will be a constant and up-to-date solution for your requirements. This goods is fabricated by the Schneider Electric brand using the freshest technologies and obeys the premier standards of protection and workmanship. We offer things from the TeSyS Deca GV4 Motor Circuit Breaker category that fuse resilience and workability, which is an exceptional option for various roles. Independent of whether you need instruments for small fabrication or for adept industrial exploitation, Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals will be a sure companion in your occupation.

Baltelec ventures to make the obtaining process as straightforward and fast as realizable for our clients. We offer detailed descriptions and high-quality photos of Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals so that you can make an conscious choice. A team of adepts is always ready to help you with any inquiries in the TeSyS Deca GV4 Motor Circuit Breaker section relevant to the preferment and use of supplies. We are confident that Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals will meet your wishes and become an significant element of your inventory for just 339.89 €.

Common Queries about Schneider Electric GV4P115B:

Recently viewed
GV4P115B - Schneider Electric
Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, Everlink terminals
278,60 € excl. VAT
345,46 € incl. VAT
Expected in 2-4 weeks