SPECIFICATIONS
Main
Device short name GV4P
Range TeSys Deca
TeSys Deca
magnetic tripping current 119 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Thermal-magnetic
Electronic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 1.5 kW at 400...415 V AC 50/60 Hz
2.2 kW at 400...415 V AC 50/60 Hz
2.5 kW at 400...415 V AC 50/60 Hz
3 kW at 400...415 V AC 50/60 Hz
2.2 kW at 500 V AC 50/60 Hz
2.5 kW at 500 V AC 50/60 Hz
3 kW at 500 V AC 50/60 Hz
4 kW at 500 V AC 50/60 Hz
3 kW at 660...690 V AC 50/60 Hz
4 kW at 660...690 V AC 50/60 Hz
5.5 kW at 660...690 V AC 50/60 Hz
7.5 kW at 660...690 V AC 50/60 Hz
Complementary
[in] rated current 7 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
65 kA at 240 V AC 50/60 Hz conforming to UL 60947
35 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
18 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Rotary handle
Product certifications IEC
UL
CSA
CCC
EAC
ATEX
EU-RO MR
Connection pitch 27 mm without spreaders
35 mm with spreaders
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals Lugs-ring terminals
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.6 kg
Operating position Any position
power dissipation per pole 4.6 W
depth 165 mm
mechanical durability 40000 cycles
electrical durability 40000 cycles for AC-3 at 440 V In/2
40000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards CSA C22.2 No 60947-4-1
UL 60947-4-1
EN/IEC 60947-4-1
EN/IEC 60947-2
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4P07N6 - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, lugs terminals is designed to serve the prerequisites of industry experts, such as control panel builders, wiremen, repair companies, and primary equipment makers. GV4P07N6 yields unmatched standards and worth for consultants in the automation and control industry. This Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, lugs terminals and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric can be purchased at the most competitive price and shipping time through BALTELEC online store, a trustworthy reseller supplying engineers in their procurement needs.

Engineers who have chosen Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have continuously praised the producer's soundness. It has been emphasized that the notable operation of GV4P07N6 - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, lugs terminals extends to a collection of deployments. Its first-rate aspects make it well-suited solution for wide-ranging specifications, guaranteeing the success of your industrial, tertiary, and automation contracts.

Our professionals centers in providing for industrial and tertiary professionals’ needs. We know the customized standards and expectations of our buyers in the field. By collaborating with BaltElec, your team secure access to the premier price and delivery period of top-tier products like GV4P07N6 - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, lugs terminals from Schneider Electric at the lowest price. Professional buyers with Baltelec account take advantage of exclusive discounts and first-class attention.

Begin today and procure GV4P07N6 - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, lugs terminals at our secure and convenient webshop. Don't delay in making this intelligent action that assures the highest quality and satisfies the personalized prerequisites of professionals like you.

If you face any problems or concerns about GV4P07N6 - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, lugs terminals or any other Schneider Electric products, connect with us or refer to our Information center section below. We have gathered answers to habitual issues to help you further in making an knowledgeable decision about industrial and tertiary electrical components.

Remember, GV4P07N6 - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, lugs terminals from Schneider Electric is dependable, cost-effective, and high-quality to market challengers in the TeSyS Deca GV4 Motor Circuit Breaker category. Make it a part of your arrangement without delay. Shop with confidence at Baltelec webstore, your respected merchant for all your TeSyS Deca GV4 Motor Circuit Breaker.

In our Baltelec.eu online store you will come across Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, lugs terminals - GV4P07N6 worth 311.03 €, which will be a safe and modern solution for your demands. This goods is created by the Schneider Electric brand using the most recent technologies and follows the top standards of defense and capability. We present merchandise from the TeSyS Deca GV4 Motor Circuit Breaker category that blend sturdiness and efficacy, which is an superior decision for various objectives. Without consideration of whether you crave tools for small formation or for adept industrial exploitation, Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, lugs terminals will be a trustworthy aid in your undertaking.

Baltelec attempts to make the buying process as effortless and fast as feasible for our customers. We offer detailed reports and high-quality visuals of Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, lugs terminals so that you can make an knowledgeable choice. A team of connoisseurs is always ready to help you with any concerns in the TeSyS Deca GV4 Motor Circuit Breaker section involved to the preferment and use of articles. We are guaranteed that Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, lugs terminals will meet your prospects and become an vital element of your equipment for just 311.03 €.

Common Queries about GV4P07N6 - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, lugs terminals:

Recently viewed
GV4P07N6 - Schneider Electric
Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, lugs terminals
254,94 € excl. VAT
316,13 € incl. VAT
Expected in 2-4 weeks