SPECIFICATIONS
Main
Device short name GV4P
Range TeSys Deca
TeSys Deca
magnetic tripping current 119 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Electronic
Thermal-magnetic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 1.5 kW at 400...415 V AC 50/60 Hz
2.2 kW at 400...415 V AC 50/60 Hz
2.5 kW at 400...415 V AC 50/60 Hz
3 kW at 400...415 V AC 50/60 Hz
2.2 kW at 500 V AC 50/60 Hz
2.5 kW at 500 V AC 50/60 Hz
3 kW at 500 V AC 50/60 Hz
4 kW at 500 V AC 50/60 Hz
3 kW at 660...690 V AC 50/60 Hz
4 kW at 660...690 V AC 50/60 Hz
5.5 kW at 660...690 V AC 50/60 Hz
7.5 kW at 660...690 V AC 50/60 Hz
Complementary
[in] rated current 7 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
65 kA at 240 V AC 50/60 Hz conforming to UL 60947
35 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
18 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Rotary handle
Product certifications IEC
UL
CSA
CCC
EAC
ATEX
EU-RO MR
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals EverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² - solid
EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² - flexible
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² - solid
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² - flexible
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.6 kg
Operating position Any position
power dissipation per pole 4.6 W
depth 165 mm
mechanical durability 40000 cycles
electrical durability 40000 cycles for AC-3 at 440 V In/2
40000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards CSA C22.2 No 60947-4-1
UL 60947-4-1
EN/IEC 60947-4-1
EN/IEC 60947-2
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4P07N - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, Everlink terminals is engineered to serve the wants of technical experts, such as switchgear manufacturers, electrical technicians, service organizations, and primary equipment suppliers. GV4P07N presents first-rate durability and advantages for engineers in the electrical engineering industry. This Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, Everlink terminals and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric are available at the optimal price and shipping time through BALTELEC, a distinguished purveyor catering to practitioners in their gathering needs.

Buyers who have opted for Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have invariably approved the brand's trustworthiness. It has been outlined that the superior performance of GV4P07N - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, Everlink terminals extends to a diverse range of tasks. Its supreme specifications make it perfect choice to suit a variety of needs, promoting success in your industrial, tertiary, and automation efforts.

Our professionals devotes in providing for industrial and tertiary professionals’ needs. We understand the particular standards and requirements of our buyers in the industry. By partnering with our specialists, our partners access access to the superior costs and delivery schedule of top-tier products like GV4P07N - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, Everlink terminals from Schneider Electric at cost-effective price. Registered customers benefit from more savings and preferred assistance.

Begin today and obtain GV4P07N - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, Everlink terminals at our well-established and streamlined online store. Don't delay in making this wise option that assures the finest quality and complies with the customized specifications of purchasers like your team.

In case you have any issues or concerns about GV4P07N - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, Everlink terminals or any other Schneider Electric products, email us or refer to our Common Questions section below. We have brought together answers to standard concerns to aid you further in making an considered decision about industrial and tertiary electrical components.

Remember, GV4P07N - Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, Everlink terminals from Schneider Electric is reliable, value-priced, and exceptional to its rivals in the TeSyS Deca GV4 Motor Circuit Breaker category. Make it a part of your configuration instantly. Purchase at Baltelec e-shop, your consistent provider for all your professional electrical equipment and automation needs.

In our Baltelec.eu web store you will uncover Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, Everlink terminals - GV4P07N worth 329.19 €, which will be a trustworthy and new solution for your needs. This object is constructed by the Schneider Electric brand using the up-to-the-minute technologies and fulfills the pinnacle standards of well-being and performance. We present products from the TeSyS Deca GV4 Motor Circuit Breaker category that merge robustness and effectiveness, which is an first-rate election for various operations. Despite of whether you seek machinery for small formation or for professional industrial use, Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, Everlink terminals will be a reliable partner in your job.

Baltelec efforts to make the securing process as easy and fast as practicable for our users. We offer detailed explanations and high-quality depictions of Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, Everlink terminals so that you can make an versed choice. A team of authorities is always ready to help you with any wonder in the TeSyS Deca GV4 Motor Circuit Breaker section tied to the preferment and use of merchandise. We are guaranteed that Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, Everlink terminals will meet your anticipations and become an key element of your apparatus for just 329.19 €.

Frequently Raised Questions about Schneider Electric GV4P07N:

Recently viewed
GV4P07N - Schneider Electric
Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic, Everlink terminals
269,83 € excl. VAT
334,59 € incl. VAT
Expected in 2-4 weeks