SPECIFICATIONS
Main
Device short name GV4L
Range TeSys Deca
TeSys Deca
magnetic tripping current 150…350 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Magnetic
Electronic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 7.5 kW at 660...690 V AC 50/60 Hz
5.5 kW at 400...415 V AC 50/60 Hz
7.5 kW at 500 V AC 50/60 Hz
9 kW at 660...690 V AC 50/60 Hz
11 kW at 660...690 V AC 50/60 Hz
7.5 kW at 400...415 V AC 50/60 Hz
9 kW at 400...415 V AC 50/60 Hz
11 kW at 400...415 V AC 50/60 Hz
9 kW at 500 V AC 50/60 Hz
11 kW at 500 V AC 50/60 Hz
15 kW at 500 V AC 50/60 Hz
15 kW at 660...690 V AC 50/60 Hz
18.5 kW at 660...690 V AC 50/60 Hz
Complementary
[in] rated current 25 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Toggle
Product certifications IEC
CCC
EAC
EU-RO MR
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals EverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² - solid
EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² - flexible
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² - solid
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² - flexible
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.5 kg
Operating position Any position
power dissipation per pole 6.1 W
depth 116 mm
mechanical durability 40000 cycles
electrical durability 40000 cycles for AC-3 at 440 V In/2
20000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards EN/IEC 60947-4-1
EN/IEC 60947-2
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4LE25N - Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 50 kA, magnetic, EverLink terminals is engineered to respond to the needs of trade buyers, such as circuit designers, wiring specialists, service organizations, and manufacturing originators. GV4LE25N yields first-rate efficiency and worth for specialists in the electrotechnical industry. This Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 50 kA, magnetic, EverLink terminals and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric are available at the most affordable rate and turnaround time through BaltElec, a dependable dealer attending to engineers in their buying needs.

Technicians who have acquired Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have consistently acclaimed the brand's reliability. It has been emphasized that the superior competence of GV4LE25N - Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 50 kA, magnetic, EverLink terminals extends to a wide range of scenarios. Its first-rate qualities make it fitting to suit a variety of needs. Your developed solution will excel in quality, energy-efficiency and price.

BaltElec devotes in fulfilling industrial and tertiary professionals’ needs. We know the customized expectations and desires of our clients in the domain. By collaborating with our professionals, your team get access to the finest price and supply timeline of high-quality products like GV4LE25N - Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 50 kA, magnetic, EverLink terminals from Schneider Electric at the lowest price. Professional buyers with Baltelec account receive further discounts and priority service.

Get started and acquire GV4LE25N - Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 50 kA, magnetic, EverLink terminals at our reliable and straightforward digital marketplace. Don't delay in making this sensible selection that certifies the supreme quality and adheres to the distinct requests of contractors like your business.

Should you have any concerns or concerns about GV4LE25N - Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 50 kA, magnetic, EverLink terminals or any other Schneider Electric products, email us or refer to our Help section section below. We have gathered answers to standard requests for information to guide you further in making an wise decision about industrial and tertiary electrical components.

Remember, GV4LE25N - Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 50 kA, magnetic, EverLink terminals from Schneider Electric is reliable, value-priced, and premier to other vendors in the TeSyS Deca GV4 Motor Circuit Breaker category. Feel free to make it a part of your configuration right now. Acquire at BaltElec, your preferred supplier for all your TeSyS Deca GV4 Motor Circuit Breaker.

In our Baltelec.eu digital store you will locate Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 50 kA, magnetic, EverLink terminals - GV4LE25N worth 267.21 €, which will be a dependable and modern solution for your expectations. This object is designed by the Schneider Electric brand using the most recent technologies and meets the uppermost standards of defense and productivity. We provide produce from the TeSyS Deca GV4 Motor Circuit Breaker category that integrate resilience and workability, which is an first-rate preference for various applications. Notwithstanding of whether you desire tools for small output or for specialized industrial implementation, Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 50 kA, magnetic, EverLink terminals will be a safe helper in your occupation.

Baltelec efforts to make the procuring process as easy and fast as accomplishable for our clients. We offer detailed explanations and high-quality photographs of Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 50 kA, magnetic, EverLink terminals so that you can make an conscious choice. A team of pros is always ready to help you with any issues in the TeSyS Deca GV4 Motor Circuit Breaker section linked to the deciding and use of wares. We are confident that Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 50 kA, magnetic, EverLink terminals will meet your hopes and become an essential element of your setup for just 267.21 €.

FAQ about Schneider Electric GV4LE25N:

Recently viewed
GV4LE25N - Schneider Electric
Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 50 kA, magnetic, EverLink terminals
219,02 € excl. VAT
271,59 € incl. VAT
Expected in 2-4 weeks