All categories
Compare Cart

GV4LE07N - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals - Schneider Electric

Expected in 2-4 weeks
GV4LE07N - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals - Schneider Electric - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals - Schneider Electric - 0
GV4LE07N - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals - Schneider Electric
219,02 € excl. VAT
271,59 € incl. VAT
Text About:
Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals - Schneider Electric
271,59 €
SPECIFICATIONS
Main
Device short name GV4L
Range TeSys Deca
TeSys Deca
magnetic tripping current 42…98 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Magnetic
Electronic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 1.5 kW at 400...415 V AC 50/60 Hz
2.2 kW at 400...415 V AC 50/60 Hz
2.5 kW at 400...415 V AC 50/60 Hz
3 kW at 400...415 V AC 50/60 Hz
2.2 kW at 500 V AC 50/60 Hz
2.5 kW at 500 V AC 50/60 Hz
3 kW at 500 V AC 50/60 Hz
4 kW at 500 V AC 50/60 Hz
3 kW at 660...690 V AC 50/60 Hz
4 kW at 660...690 V AC 50/60 Hz
5.5 kW at 660...690 V AC 50/60 Hz
7.5 kW at 660...690 V AC 50/60 Hz
Complementary
[in] rated current 7 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Toggle
Product certifications IEC
CCC
EAC
EU-RO MR
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals EverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² - solid
EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² - flexible
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² - solid
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² - flexible
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.5 kg
Operating position Any position
power dissipation per pole 6.1 W
depth 116 mm
mechanical durability 40000 cycles
electrical durability 40000 cycles for AC-3 at 440 V In/2
40000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards EN/IEC 60947-2
EN/IEC 60947-4-1
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4LE07N - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals is crafted to respond to the necessities of industry specialists, such as system integrators, electric engineers, repair companies, and Industry suppliers. GV4LE07N dispenses first-rate reliability and merit for contractors in the power systems industry. This Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric are accessible at the optimal price and lead time through BALTELEC, a distinguished reseller fulfilling the needs of consultants in their collection needs.

Patrons who have purchased Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have frequently approved the producer's durability. It has been noted that the remarkable performance of GV4LE07N - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals extends to a assortment of tasks. Its top-notch properties make it suitable for different applications. Your developed solution will excel in quality, energy-efficiency and price.

BaltElec team concentrates in meeting industrial and tertiary professionals’ needs. We grasp the distinct needs and anticipations of our consumers in the market. By collaborating with BALTELEC, our customers acquire access to the leading price lists and supply timeline of the top-of-the-line products like GV4LE07N - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals from Schneider Electric at a reasonable price. Our registered accounts benefit from added discounts and expedited requests handling.

Make a move and secure GV4LE07N - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals at our well-established and user-friendly web store. Don't delay in making this prudent move that secures the greatest quality and adheres to the individual prerequisites of traders like yourselves.

If you face any worries or concerns about GV4LE07N - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals or any other Schneider Electric products, message us or refer to our FAQs section below. We have assembled answers to habitual concerns to advise you further in making an well-considered decision about industrial and tertiary electrical components.

Remember, GV4LE07N - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals from Schneider Electric is steady, cost-effective, and exceptional to opposing companies in the TeSyS Deca GV4 Motor Circuit Breaker category. Make it a part of your configuration straight away. Acquire at BALTELEC, your respected merchant for all your TeSyS Deca GV4 Motor Circuit Breaker.

In our Baltelec.eu electronic store you will spot Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals - GV4LE07N worth 267.21 €, which will be a sure and current solution for your wants. This item is constructed by the Schneider Electric brand using the up-to-the-minute technologies and conforms to the pinnacle standards of protection and efficacy. We provide produce from the TeSyS Deca GV4 Motor Circuit Breaker category that amalgamate endurance and operability, which is an excellent selection for various functions. In defiance of whether you necessitate appliances for small assembly or for specialized industrial application, Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals will be a safe companion in your occupation.

Baltelec ventures to make the procuring process as comfortable and fast as realizable for our buyers. We offer detailed narratives and high-quality illustrations of Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals so that you can make an enlightened choice. A team of maestros is always ready to help you with any queries in the TeSyS Deca GV4 Motor Circuit Breaker section involved to the choice and use of supplies. We are sure that Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals will meet your needs and become an significant element of your machinery for just 267.21 €.

Frequently Raised Questions about Schneider Electric GV4LE07N:

Recently viewed
GV4LE07N - Schneider Electric
Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals
219,02 € excl. VAT
271,59 € incl. VAT
Expected in 2-4 weeks